General information
System requirements
Automation Studio 4.3.3 or later
Automation Runtime B4.34 or later
mapp Technology Package mapp Services
Basic package license 1TGMPSRV.00-01
Behavior if license missing License violation indicated by red blinking LED
物料号:
1TGMPASSET.20-01
描述:
  • Calculating statistical data for a machine
  • Storing data as a CSV file
  • Comparing the productivity of multiple shifts, machines or sites

mapp Asset Intensity collects all of a machine's statistical data. This data is then displayed in an HMI application in either a table or graph format for further analysis. The collected data can be exported to a data storage device such as a USB flash drive, for example.

典型应用:
  • Comparing productivity of multiple shifts
  • Comparing downtime of multiple machines
  • Overview of collected statistical data in graph form
功能范围:

mapp Asset Intensity collects statistical data from a machine, such as production rate and planned and unplanned downtime. The data can be summarized for a day, shift or batch, among other things. Data can be shown in the HMI application as either a table or graph as well as exported to a CSV file.

更多信息:

See the EULA at www.br-automation.com/eula.

必备附件
Technology Guard
1TGMPSRV.00-01 Basic license for mapp Services Required to use extended functions of the mapp Technology Package. This license includes mapp AlarmX (alarm management), mapp IO (dynamic hardware configuration), mapp User (user management), mapp Alarm (alarm management with reference to VC4), mapp File (file explorer), mapp Skyline (visualization of a machine line in combination with a mapp View widget), mapp J1939 (SAE J1939 protocol) and mapp Recipe (recipe management).
可选附件
Hardware Key -Dongle
0TG1000.02 Technology Guard (HID)
Other functions
X20cCMR011 X20 cabinet monitoring module, coated, integrated temperature sensor, moisture sensor and accelerometer, production data acquisition, 2 inputs for external Pt1000, 2 digital inputs 24 V, 1 digital output 24 V, 0.5 A, 512 kB flash memory for user data
X20CMR011 X20 cabinet monitoring module, integrated temperature sensor, moisture sensor and accelerometer, production data acquisition, 2 inputs for external PT1000, 2 digital inputs 24 V, 1 digital output 24 V, 0.5 A, 512 kB flash memory for user data
X20CMR100 X20 cabinet monitoring module, integrated temperature and humidity sensor, production data acquisition, integrated Technology Guard
X20CMR111 X20 cabinet monitoring module, integrated temperature sensor, moisture sensor and accelerometer, production data acquisition, 2 inputs for external Pt1000, 2 digital inputs 24 V, 1 digital output 24 V, 0.5 A, 512 kB flash memory for user data, integrated Technology Guard
Technology Guard
0TG1000.01 Technology Guard (MSD)
0TGF016.01 Technology Guard (MSD) with integrated flash drive, 16 GB (MLC)
Automation Studio帮助升级 版本(日期) 下载
mapp AssetInt: Asset intensity PDF / 3 MB
证书 版本(日期) 下载
EULA (End User License Agreement) - AS, AR & mapp Technology PDF / 130 KB

请选择国家和语言

B&R Logo