Short description
Interfaces | POWERLINK |
System module | CPU |
General information
B&R ID code | 0xDD61 |
System requirements | |
Automation Studio | 4.0.16 or later |
Automation Runtime | V3.08 or later (for AsSafety library F4.06 or later) |
SafeDESIGNER | 3.1.0 or later |
Safety Release | 1.7 or later |
Cooling | Fanless |
Status indicators | CPU function, POWERLINK, SafeKEY |
Diagnostics | |
CPU function | Yes, using status LED |
POWERLINK | Yes, using status LED |
SafeKEY | Yes, using status LED |
Power consumption | 4.3 W |
Certifications | |
CE | Yes |
Functional safety |
cULus FSPC E361559 Energy and industrial systems Certified for functional safety ANSI UL 1998:2013 |
Functional safety |
IEC 61508:2010, SIL 3 EN 62061:2013, SIL 3 EN ISO 13849-1:2015, Cat. 4 / PL e IEC 61511:2004, SIL 3 |
Functional safety | EN 50156-1:2004 |
ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
UL |
cULus E115267 Industrial control equipment |
HazLoc |
cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
DNV GL |
Temperature: A (0 - 45°C) Humidity: B (up to 100%) Vibration: A (0.7 g) EMC: B (bridge and open deck) |
KR | Yes |
EAC | Yes |
Safety characteristics
EN ISO 13849-1:2015 | |
Category | Cat. 4 |
PL | PL e |
DC | >94% |
MTTFD | 2500 years |
Mission time | Max. 20 years |
IEC 61508:2010, IEC 61511:2004, EN 62061:2013 |
|
SIL CL | SIL 3 |
SFF | >90% |
PFH / PFHd | |
Module | <1*10-10 |
openSAFETY wired | Negligible |
openSAFETY wireless | <1*10-14 * Number of openSAFETY packets per hour |
PFD | <2*10-5 |
Proof test interval (PT) | 20 years |
Functionality
Communication with each other | Yes |
Support for Safe Commissioning Options | |
BOOL | 512 |
INT | 64 |
UINT | 64 |
DINT | 64 |
UDINT | 64 |
SafeMOTION support | Yes, depends on the number of available operating licenses on the SafeKEY |
Timing precision | Time * 0.05 + Cycle time of the safety application |
Shortest task class cycle time | 1 ms |
Max. number of openSAFETY nodes | 100, depends on the number of available operating licenses on the SafeKEY |
Max. number of POWERLINK controlled nodes | 50 |
Data exchange between CPU and SafeLOGIC controller | |
Max. total data width for each direction | 512 bytes |
Max. number of data points for each direction | |
BOOL | 1024 |
INT | 128 |
UINT | 128 |
DINT | 64 |
UDINT | 64 |
Limit values for SafeDESIGNER application
Input SL / BC / X2X Link power supply
Input voltage | 24 VDC -15% / +20% |
Input current | Max. 0.25 A |
Fuse | - |
Reverse polarity protection | Yes |
Interfaces
Operating conditions
Mounting orientation | |
Horizontal | Yes |
Vertical | Yes |
Installation elevation above sea level | 0 to 2000 m, no limitation |
Degree of protection per EN 60529 | IP20 |
Ambient conditions
Temperature | |
Operation | |
Horizontal mounting orientation | 0 to 60°C |
Vertical mounting orientation | 0 to 45°C |
Derating | - |
Storage | -40 to 85°C |
Transport | -40 to 85°C |
Relative humidity | |
Operation | 5 to 95%, non-condensing |
Storage | 5 to 95%, non-condensing |
Transport | 5 to 95%, non-condensing |
Mechanical properties
Note |
Order SafeKEY and SafeLOGIC range of functions using the X20MK configurator. X20 end cover plate (right) included in delivery. 12-pin X20 terminal block, safety-keyed, included in delivery. SafeKEY cover included in delivery. |
Dimensions | |
Width | 62.5+0.2 mm |
Height | 99 mm |
Depth | 75 mm |
Weight | 190 g |

Material number:
X20SL8100Description:
- openSAFETY manager for up to 100 SafeNODEs
- Flexibly programmable using Automation Studio / SafeDESIGNER
- Innovative management of safe machine options (SafeOPTION)
- Parameter and configuration management
The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3.
In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed by the SafeLOGIC controller.
Mandatory Accessories
Accessories
X20MK0223 | X20 SafeKEY, 8 MB, for the X20SL81xx series, exclusively for mapp Safety, range of license functions determined via Technology Guarding in Automation Runtime |
X20MKXXXX.XXX.XXX | "Safety Technology Guarding" defines the range of functions available for applications using X20SL81xx- or X20cSL81xx-series SafeLOGIC controllers. Licenses are stored on a SafeKEY dongle. The functions required for the application must be put together in the X20MK configurator by selecting a SafeKEY with a sufficient amount of memory, a coated/non-coated variant and the necessary technology functions. Each solution is delivered exclusively as a set consisting of the SafeKEY and the activated licenses for the selected technology functions. |
Automation Studio HW Upgrades | Version (Date) | Download |
---|---|---|
V4.0 HW Upgrade (X20SL8100) | EXE / 6 MB | |
V4.6 HW Upgrade (X20SL8100) | EXE / 2 MB |
Documentation | Version (Date) | Download |
---|---|---|
Data sheet X20(c)SL81xx - Legacy | PDF / 7 MB | |
Data sheet X20(c)SL81xx - mapp Safety | PDF / 4 MB | |
information sheet SafeLOGIC | PDF / 553 KB |
E-CAD (Electro or EPLAN Templates) | Version (Date) | Download |
---|---|---|
X20 EPLAN P8 from V2.4 | EXE / 161 MB |
M-CAD (Mechan. Templates) | Version (Date) | Download |
---|---|---|
3D File DXF/STEP X20SL810x | ZIP / 7 MB |
Tools / Utilities / Examples | Version (Date) | Download |
---|---|---|
Sistema library | ZIP / 319 KB |