DWL@DWL10000782874
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
2.6.0.2 | * | 19.04.2024 | 6 MB | EXE | AS6_HW_X20cSLX410.exe | |
Popis |
V6.0 HW Upgrade (X20cSLX410) Revision information X20cSLX410 Version 2.6.0.2: ID: 782390 AutomationSoftware 6.x support AutomationSoftware 6.x Channel description changed: No Configuration description changed: No Firmware changed: No ID: 782530 logger messages "Inconsistent UDID files" / "Set-to-operational for unacknowledgedUDID" Fix -1073552872 "Inconsistent UDID files" / -1073552680 "Set-to-operationalfor unacknowledged UDID" (fix available for AR >= B4.92) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\57992_1.fw(593), 11\57992_1.fw(593) Version 2.6.0.1: ID: 780155 Correction of the input filter with set "Filter off". Correction of the input filter, if a "Filter off" isset and a channel erroris detected. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 780240 New data sheet V2.20 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configurationdescription changed: No Firmware changed: No ID: 780410 / Support ID: 400412437 Configuration for Power Calculation available The Configuration for Power Calculation is now available in Automation Studio Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\57992_1.fw(593) Version 2.4.1.1: ID: 710990 / Support ID: 400324450 Data sheet: Improved description of max data width Data sheet: Improved description of max data width Channel description changed: No Configuration description changed: No Firmware changed: No ID: 721460 data sheet V2.10 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 726665 The power calculation of themodules is supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\57992_1.fw(591) Version 2.4.0.1: ID: 688910 data sheet V2.08 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 691585 Improvement of the internalvoltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 694315 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:699595 Support of the DYNlink interface The DYNlink interface is supported by the safe inputs. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 701900 The OSDD signal at the pulse output is corrected. The OSDD signal atthe pulse output is output correctly even when not in use. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\57992_1.fw(591) Version 2.2.0.0: ID: 671500 SafeDOMAIN-to-SafeDOMAIN communication Support SafeDOMAIN-to-SafeDOMAIN communication between SafeLOGIC and SafeLOGIC-X (requires mappSafety 5.10 or higher) Channel description changed: Yes Configurationdescription changed: Yes Firmware changed: No ID: 674375 data sheet V2.05 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\57992_1.fw(570) Version 2.1.0.4: ID: 668575 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\57992_1.fw(570) Version 2.1.0.3: ID: 637415 new AR targets support new AR targets X20CPx68x and xPC22xx Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\57992_1.fw(570) Version 2.1.0.1: ID: 541680 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 628070 safety response time The check of thenetwork transmission time of cyclic data tolerated values up to 12ms higher than configured by the parameters "safe data duration"/"additional tolerated packet loss". This could lead to an increased safety response time. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 644585 Setup Mode signaling Setup Mode is now signaled with "S" and "E" LED. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\57992_1.fw(570) Version 1.10.10.3: ID: 626170 data sheet V1.141 See chapture "Version history" in thedata sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 637425 fix logger entry 123622 SLX didn't enter RUN state and logger number 123622 was entered when using 10other safety modules. Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 4\57992_1.fw(313), 5\57992_1.fw(330) Version 1.10.10.1: ID: 637415 new AR targets support new AR targets X20CPx68x and xPC22xx Channel description changed: No Configuration description changed: No Firmwarechanged: No ID: 637425 fix logger entry 123622 SLX didn't enter RUN state and logger number 123622 was entered when using 10 other safety modules. Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 4\57992_1.fw(313), 5\57992_1.fw(330) Version 1.10.10.0: ID: 626170 safety response time The check of the network transmission time of cyclic data tolerated values up to 12ms higher than configured by the parameters "safe data duration"/"additional tolerated packet loss". This could lead to an increased safety response time. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 4\57992_1.fw(313), 5\57992_1.fw(330) Version 1.10.9.0: ID: 618245 loggerentry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 4\57992_1.fw(313), 5\57992_1.fw(330) Version 1.10.5.0: ID: 582825 logger message 106773 Fix for logger message 106773 "Parameter checksum sizes do not match". Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 4\57992_1.fw(313), 5\57992_1.fw(326) Version 1.10.4.1: ID: 585670 channel error when wired to +24V Temporary channel errors (logger entry 115011)are reported if If channels are wired to +24V during module bootup. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 589970 additional parameters Support additonal parameters (AsSafety FBK safeDownloadData_V2.Type=safeDATA_TYPE_ADDPARA); requires AR >= A04.41 ! Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 589975 fix CLEAR DATA Not all relevant data has been deleted upon command "CLEAR DATA" Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 589980 loggerentry 123432 fixed logger entry 123432 when using setup mode in combination with machineoptions Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 589985 bootup time increase of bootup time with Upgrade V1.10.2.9 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 589990 increased tolerance against asynchronous communication problems Problems in asynchronous communication to safety modules now cause the modules to be rated as "missing" not until the "Node Guarding Timeout" has expired(instead of after a few seconds) Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 589995 extended operating temperature range Firmware preparation for hardware revisions that allow operating temperature range down to -40°C. Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 4\57992_1.fw(313), 5\57992_1.fw(326) Version 1.10.3.2: ID: 549110 / Support ID: 400225917 Correction of SLX download frame Correction of SLX download frame Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 4\57992_1.fw(313), 5\57992_1.fw(324) Version 1.10.3.1: ID: 537600 logger message 110367 with external maschine options SLX did not boot correctly whenusing external machine options with upgrade V1.10.2.9 (logger message 110367 and others). Channel description changed: No Configuration description changed: No Firmware changed: No ID: 537605 logger message 123416 when aknowledging a firmware mismatch The command for firmware acknowledgement was accepted although there was still a SCAN in progress. Thiscould lead to a failure with logger message 123416. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 4\57992_1.fw(313), 5\57992_1.fw(324) Version 1.10.2.9: ID: 381670 / Support ID: 400132230 X20(c)SLX910: warn about invalid two channel processing mode X20(c)SLX910: SafeDESIGNER generates a warning during compile if a two-channel evaluation channel is used but the according parameter "Two Channel Processing Mode" is "none". Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 481780 / Support ID: 400199480 error message about incompatible AR version Error message during AutomationStudio compile when trying to use Safety Release 1.10 with an AR version that is too old. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 494085 Improve SLX cycle time Performance optimization for improvement of internal SLX cycle time. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 494095 online help V1.103 Update online help to V1.103 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 502230 supportAcopos P3 (X20SLX210 and X20SLX410 only) X20SLX210 and X20SLX410 supportall variants of Acopos P3 (X20SLX910 supports 1 axis only) Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 513925 / Support ID: 400193973, 400206803 SLXbootState 54 SLXbootState never reached value 54 "SafeRUN" although SLX booted correctly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 516045 fixes for parameters in SafeDESIGNER Minor text corrections. Remove obsolete parameter "Cycle time". Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 521125 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 522940 Error while downloading big SafeDESIGNER applications to the SLX. Download was aborted and the message "File Unlock Status: Error while writing unlock status!" was shown. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 522945 Setup Mode and automated acknowledgements - Setup Mode is supported (requires SafeDESIGNER 4.3 and AutomationRuntime B4.26 or higher) - new parameters for automated acknowledgement of SafeKEY and firmware exchange. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 528960 SafeOS Status in SafeDESIGNERRemote Control It is a known issue that the SafeOS status in SafeDESIGNER remote control is not shown correctly when using certain versions. SafeDESIGNER SafePLC window or AsSafety can be used instead. This affects a set of following versions: SLX Upgrade >=V1.10.2.x, Safety Release 1.10, SafeDESIGNER >=V4.2.3 and AR B4.26 to C4.26 or C4.33 to E4.33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 4\57992_1.fw(313), 5\57992_1.fw(324) Version 1.10.0.0: ID: 374990 / Support ID: 400129134 SafeDESIGNER communication Variable status Frequent activating/deactivating of SafeDESIGNER variable status could leadto failure of SLX communication. Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 390095 / Support ID: 400137073 informations about actual application CRC and timestamp of the SafeDESIGNER application that is actually stored on the SLX can be read via asynchronous data points. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 411790 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5with easier parametrizationof timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 426855 / Support ID: 400151377 Optional modules no longerreported missing via SLX LEDs Channel description changed: No Configuration description changed: No Firmware changed: No ID: 440400/ Support ID: 400147709, 400160605, 400165854, 400175456 Input checksum data error In rare cases it could happen sporadically that the SLX entered failsafe state with "Input checksum data error" (logger messages 69648, 73744, 69655 und 73751) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448715 application download Performance optimization of application download to SLX. Some sequences have been changes for this which omitted some of the valuesof SLXbootState. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448980 / Support ID: 400162839, 400168358 limit of max 1 SLX per CPU / line integration If there are more then one SLX in the AS hardware tree, only one of them maybe enabled. On the other hand now it is allowed to download a SafeDESIGNERapplication that doesn't match the SafeLOGIC-ID of the AS hardware tree. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 4\57992_1.fw(313), 5\57992_1.fw(320) Version 1.9.2.0: ID: 450785 / Support ID: 400137924 SafeLOGIC-X with Panal PC SafeLOGIC-X didn't work with some Panal PCs (e.g. 5PC901 and 5PPC2100) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 4\57992_1.fw(313) Version 1.9.1.0: ID: 425385 change of input filter The behaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 425390 Update Online Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 425395 fw valid from SafetyRelease 1.8 on The firmware is used for all SafetyReleases from 1.8 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 425400 Default values changed Default values of Cycle_Time_typical_us and Default_Max_X2X_CycleTime_us changed Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 4\57992_1.fw(313) Version 1.9.0.0: ID: 419950 The module also supports SafetyRelease 1.9 Starting with this version, the module also supports SafetyRelease 1.9 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 419955 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 2\57992_1.fw(311) Version 1.8.0.3: ID: 393855 first official release first official release Channel description changed: Yes Configurationdescription changed: Yes Firmware changed: Yes Firmware: 2\57992_1.fw(311) |