DWL@DWL10000604617
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
2.6.0.0 | * | 05.03.2024 | 2 MB | EXE | AS4_HW_X20SC2212.exe | |
Popis |
V4.6 HW Upgrade (X20SC2212) Revision information X20SC2212 Version 2.6.0.0: ID: 780140 Correction of the input filter with set "Filter off". Correction of the input filter, if a "Filter off" is set and a channel error is detected. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 780260 New data sheet V2.20 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 780385 / Support ID: 400412437 Configuration for Power Calculation available The Configuration for Power Calculation is now available in Automation Studio Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\48549_1.fw(580) Version 2.4.0.0: ID: 715235 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 726600 The power calculation of the modules is supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID:727120 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\48549_1.fw(574) Version 2.3.0.1: ID: 692345 Support of the DYNlink interface The DYNlink interface is supported by the safe inputs. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 692385 The OSDD signal at the pulse output is corrected. The OSDD signal at the pulse output is output correctly even when not in use. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 696555 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 706315 Limit values forthe module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\48549_1.fw(573) Version 2.2.0.0: ID: 668545 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688715 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration"is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689700 Propagation delay statistics The Propagation delay statisticscan now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689895 Increased delay of external feedback error detection Increased delay of external feedback error detection Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689930 Improvement of the internal voltage monitoring. Improvement of theinternal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690000 Improvement of the feedback diagnosis. Improvement of the feedback diagnosis of the output. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690075 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\48549_1.fw(571) Version 2.1.0.0: ID: 644280 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\48549_1.fw(570) Version 1.10.9.1: ID: 643475 data sheet V1.141 See chapture "Versionhistory" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(330) Version 1.10.9.0: ID: 618215 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically withlarge projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\48549_1.fw(301), 6\48549_1.fw(330) Version 1.10.1.2: ID: 541660 New default values The default values for "Filter On" and "Discrepancy Time" havebeen modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 552660 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 552665 Loggerentry on negativ edge of SafeModuleOK Ifa negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(326) Version 1.10.0.6: ID: 533015 Add blackout mode Addblackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533100 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(320) Version 1.10.0.1: ID: 470500 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 470505 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(320) Version 1.9.1.0: ID: 425430 change of input filter Thebehaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 425435 fw valid from SafetyRelease 1.2 on The firmware is used for all SafetyReleases from 1.2 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 425440 Update Online Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301) Version 1.9.0.0: ID: 413810 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 413915 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414215 parameter max. Switching Frequency removed Parameter max.Switching Frequency has no meaning any more. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 414290 2-channel evaluation: additional information at warning If warning "discrepancy time elapsed" appears for 2-channel evaluation, info0 will now display the chosen PLCopen FBK (equivalent or antivalent). Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 414315 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290), 4\48549_1.fw(300) Version 1.6.0.8: ID: 388330 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.6.0.7: ID: 339220 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:3\48549_1.fw(290) Version 1.6.0.5: ID: 335305 The modulealso supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335315/ Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.6.0.0: ID: 314165 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.5.0.4: ID: 303350 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:3\48549_1.fw(290) Version 1.5.0.2: ID: 294895 corrected AutomationStudio Help Corrections in Automation Studio Help done Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.5.0.1: ID: 283685 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.4.0.0 | * | 09.06.2021 | 1 MB | EXE | AS4_HW_X20SC2212.exe | |
Popis |
V4.6 HW Upgrade (X20SC2212) Revision information X20SC2212 Version 2.4.0.0: ID: 715235 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 726600 The power calculation of the modules is supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727120 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\48549_1.fw(574) Version 2.3.0.1: ID: 692345 Support of the DYNlink interface The DYNlink interface is supported by the safe inputs. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 692385 The OSDD signal at the pulse output is corrected. The OSDD signal at the pulse output is output correctly even when not in use. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 696555 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 706315 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\48549_1.fw(573) Version 2.2.0.0: ID: 668545 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688715 / Support ID: 400299371 Loss of safetyconnection Loss of safety connection, even though the parametrized "safedata duration"is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689700 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:689895 Increased delay of external feedback error detection Increased delay of external feedback error detection Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689930 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 690000 Improvement of the feedback diagnosis. Improvement of the feedback diagnosis of the output. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690075 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\48549_1.fw(571) Version 2.1.0.0: ID: 644280 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\48549_1.fw(570) Version 1.10.9.1: ID: 643475 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(330) Version 1.10.9.0: ID: 618215 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\48549_1.fw(301), 6\48549_1.fw(330) Version 1.10.1.2: ID: 541660 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 552660 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 552665 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(326) Version 1.10.0.6: ID: 533015 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533100 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(320) Version 1.10.0.1: ID: 470500 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 470505 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(320) Version 1.9.1.0: ID: 425430 change of input filter The behaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 425435 fw valid from SafetyRelease 1.2 on Thefirmware is used for all SafetyReleases from 1.2 on. Channel descriptionchanged: No Configuration description changed: Yes Firmware changed: No ID: 425440 Update Online Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301) Version 1.9.0.0: ID: 413810 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channeldescription changed: No Configuration description changed: Yes Firmware changed: No ID: 413915 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414215 parameter max. Switching Frequency removed Parameter max. Switching Frequency has no meaning any more. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 414290 2-channel evaluation: additional information at warning If warning "discrepancy time elapsed" appears for 2-channel evaluation, info0 will now display the chosen PLCopen FBK (equivalent or antivalent). Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 414315 Update OnlineHelp Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:3\48549_1.fw(290), 4\48549_1.fw(300) Version 1.6.0.8: ID: 388330 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.6.0.7: ID: 339220 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.6.0.5: ID: 335305 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335315 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.6.0.0: ID: 314165 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.5.0.4: ID: 303350 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.5.0.2: ID: 294895 corrected AutomationStudio Help Corrections in Automation Studio Help done Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.5.0.1: ID: 283685 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.3.0.1 | * | 01.12.2020 | 1 MB | EXE | AS4_HW_X20SC2212.exe | |
Popis |
V4.6 HW Upgrade (X20SC2212) Revision information X20SC2212 Version 2.3.0.1: ID: 692345 Support of the DYNlink interface The DYNlink interface is supported by the safe inputs. Channel description changed: No Configuration description changed: Yes Firmware changed:Yes ID: 692385 The OSDD signal at the pulse output is corrected. The OSDD signal at the pulse output is output correctly even when not in use. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 696555 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 706315 Limit values for the module cycletime adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\48549_1.fw(573) Version 2.2.0.0: ID: 668545 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688715 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689700 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689895 Increased delay of external feedback error detection Increased delay of external feedback error detection Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689930 Improvement of the internal voltage monitoring. Improvement of the internal voltagemonitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690000 Improvementof the feedback diagnosis. Improvement of the feedback diagnosis of the output. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690075 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\48549_1.fw(571) Version 2.1.0.0: ID: 644280 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\48549_1.fw(570) Version 1.10.9.1: ID: 643475 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(330) Version 1.10.9.0: ID: 618215 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\48549_1.fw(301), 6\48549_1.fw(330) Version 1.10.1.2: ID: 541660 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 552660 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 552665 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(326) Version 1.10.0.6: ID: 533015 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533100 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(320) Version 1.10.0.1: ID: 470500 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 470505 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(320) Version 1.9.1.0: ID: 425430 change of input filter The behaviour of theinput filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 425435 fw valid from SafetyRelease 1.2 on The firmware is used for all SafetyReleases from 1.2 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 425440 Update Online Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301) Version 1.9.0.0: ID: 413810 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 413915 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configurationdescription changed: Yes Firmware changed: No ID: 414215 parameter max. Switching Frequency removed Parameter max. Switching Frequency has no meaning any more. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 414290 2-channel evaluation: additional information at warning If warning "discrepancy time elapsed" appears for 2-channel evaluation, info0 will now display the chosen PLCopen FBK (equivalent or antivalent). Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 414315 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290), 4\48549_1.fw(300) Version 1.6.0.8: ID: 388330 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.6.0.7: ID: 339220 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.6.0.5: ID: 335305 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335315 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 arenow unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.6.0.0: ID: 314165 Adaption of module configurationfile release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.5.0.4: ID: 303350 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.5.0.2: ID: 294895 corrected AutomationStudio Help Corrections in Automation Studio Help done Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.5.0.1: ID: 283685 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.2.0.0 | * | 21.07.2020 | 1 MB | EXE | AS4_HW_X20SC2212.exe | |
Popis |
V4.6 HW Upgrade (X20SC2212) Revision information X20SC2212 Version 2.2.0.0: ID: 668545 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688715 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689700 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689895 Increased delay of external feedback error detection Increased delay of external feedback error detection Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689930 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690000 Improvement of the feedback diagnosis. Improvement of the feedback diagnosis of the output. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690075 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:10\48549_1.fw(571) Version 2.1.0.0: ID: 644280 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching tomapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\48549_1.fw(570) Version 1.10.9.1: ID: 643475 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(330) Version 1.10.9.0: ID:618215 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\48549_1.fw(301), 6\48549_1.fw(330) Version 1.10.1.2: ID: 541660 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 552660 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 552665 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(326) Version 1.10.0.6: ID: 533015 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533100 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(320) Version 1.10.0.1: ID: 470500 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 470505 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(320) Version 1.9.1.0: ID: 425430 change of input filter The behaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 425435 fw valid from SafetyRelease 1.2 on The firmware is used for all SafetyReleases from 1.2 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 425440 Update Online Help Update OnlineHelp V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301) Version 1.9.0.0: ID: 413810 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 413915 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channeldescription changed: No Configuration description changed: Yes Firmware changed: No ID: 414215 parameter max. Switching Frequency removed Parameter max. Switching Frequency has no meaning any more. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 414290 2-channel evaluation: additional information at warning If warning "discrepancy time elapsed" appears for 2-channel evaluation, info0 will now display the chosen PLCopen FBK (equivalent or antivalent). Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 414315 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290), 4\48549_1.fw(300) Version 1.6.0.8: ID: 388330 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.6.0.7: ID: 339220 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.6.0.5: ID: 335305 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335315 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.6.0.0: ID: 314165 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.5.0.4: ID: 303350 Supportof AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.5.0.2: ID: 294895 corrected AutomationStudio Help Corrections in AutomationStudio Help done Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.5.0.1: ID: 283685 First Official Release First Official Release Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.1.0.0 | * | 05.07.2019 | 919 KB | EXE | AS4_HW_X20SC2212.exe | |
Popis |
V4.6 HW Upgrade (X20SC2212) Revision information X20SC2212 Version 2.1.0.0: ID: 644280 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\48549_1.fw(570) Version 1.10.9.1: ID: 643475 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(330) Version 1.10.9.0: ID: 618215 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 5\48549_1.fw(301), 6\48549_1.fw(330) Version 1.10.1.2: ID: 541660 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configurationdescription changed: Yes Firmware changed: No ID: 552660 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 552665 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(326) Version 1.10.0.6: ID: 533015 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533100 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(320) Version 1.10.0.1: ID: 470500 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 470505 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301), 6\48549_1.fw(320) Version 1.9.1.0: ID: 425430 change of input filter The behaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 425435 fw valid from SafetyRelease 1.2 on The firmware is used for all SafetyReleases from 1.2 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 425440 Update Online Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 5\48549_1.fw(301) Version 1.9.0.0: ID: 413810 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 413915 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414215 parameter max. Switching Frequency removed Parameter max. Switching Frequency has no meaning any more. Channel descriptionchanged: Yes Configuration description changed: No Firmware changed: Yes ID: 414290 2-channel evaluation: additional information atwarning If warning "discrepancy time elapsed" appears for 2-channel evaluation, info0 will now display the chosen PLCopen FBK (equivalent or antivalent). Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 414315 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290), 4\48549_1.fw(300) Version 1.6.0.8: ID: 388330 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.6.0.7: ID: 339220 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.6.0.5: ID: 335305 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335315 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.6.0.0: ID: 314165 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.5.0.4: ID: 303350 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.5.0.2: ID: 294895 corrected AutomationStudio Help Corrections in Automation Studio Help done Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) Version 1.5.0.1: ID: 283685 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\48549_1.fw(290) |