DWL@DWL10000608478

Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.10.10.4 * 30.09.2019 6 MB EXE AS4_HW_X20SLX402.exe
Popis V4.1 HW Upgrade (X20SLX402)

Revision information X20SLXxxx

Version 1.10.10.4:

ID: 650950
new AR targets
support new AR targets X20CPx68x and xPC22xx
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59370_1.fw(330)

Version 1.10.10.3:

ID: 626175
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 635320 / Support ID: 400280438, 400278830, 400284804
fix logger entry 123622
SLX didn't enter RUN state and logger number 123622 was entered when using 10 other safety modules.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59370_1.fw(330)

Version 1.10.9.0:

ID: 618250
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59370_1.fw(330)

Version 1.10.5.0:

ID: 580755
logger message 106773
Fix for logger message 106773 "Parameter checksum sizes do not match".
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59370_1.fw(326)

Version 1.10.4.1:

ID: 509350
additional parameters
Support additonal parameters (AsSafety FBK safeDownloadData_V2.Type=safeDATA_TYPE_ADDPARA); requires AR >= A04.41 !
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 516155 / Support ID: 400208127
channel error when wired to +24V
Temporary channel errors (logger entry 115011) are reported if If channels are wired to +24V during module bootup.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 532570
Blackout mode and Standalone mode
support Blackout mode and Standalone mode
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 535055
increased tolerance against asynchronous communication problems
Problems in asynchronous communication to safety modules now cause the modules to be rated as "missing" not until the "Node Guarding Timeout" has expired (instead of after a few seconds)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 542710 / Support ID: 400221412, 400225768
bootup time
increase of bootup time with Upgrade V1.10.2.9
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 548835 / Support ID: 400229868, 400229876
logger entry 123432
fixed logger entry 123432 when using setup mode in combination with machine options
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 552380
fix CLEAR DATA
Not all relevant data has been deleted upon command "CLEAR DATA"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 570175
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 590000
extended operating temperature range
Firmware preparation for hardware revisions that allow operating temperature range down to -40°C.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59370_1.fw(326)

Version 1.10.3.2:

ID: 548175 / Support ID: 400225917
Correction of SLX download frame
Correction of SLX download frame
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59370_1.fw(324)

Version 1.10.3.1:

ID: 529570 / Support ID: 400215470
logger message 123416 when aknowledging a firmware mismatch
The command for firmware acknowledgement was accepted although there was still a SCAN in progress. This could lead to a failure with logger message 123416.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 535550 / Support ID: 400218871, 400219483
logger message 110367 with external maschine options
SLX did not boot correctly when using external machine options with upgrade V1.10.2.9 (logger message 110367 and others).
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59370_1.fw(324)

Version 1.10.2.9:

ID: 396185
support Acopos P3
support all variants of Acopos P3
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 475780 / Support ID: 400183890
Error while downloading big SafeDESIGNER applications to the SLX.
Download was aborted and the message "File Unlock Status: Error while writing unlock status!" was shown.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 483140 / Support ID: 400201298
error 115024 during bootup
SLX switched to failsafe mode (error number 115024) during bootup in certain projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 486375 / Support ID: 400190038
support lower "Safe Data Duration" values
Internal optimizations lead to support of lower values for "Safe Data Duration"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 501965
Setup Mode and automated acknowledgements
- Setup Mode is supported (requires SafeDESIGNER 4.3 and AutomationRuntime B4.26 or higher)
- new parameters for automated acknowledgement of SafeKEY and firmware exchange.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 516040
fixes for parameters in SafeDESIGNER
Minor text corrections.
Remove obsolete parameter "Cycle time".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 519865
warn about invalid two channel processing mode
SafeDESIGNER generates a warning during compile if a two-channel evaluation channel is used but the according parameter "Two Channel Processing Mode" is "none".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 519940
warn about invalid two channel processing mode
SafeDESIGNER generates a warning during compile if a two-channel evaluation channel is used but the according parameter "Two Channel Processing Mode" is "none".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 520155
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 528955
SafeOS Status in SafeDESIGNER Remote Control
It is a known issue that the SafeOS status in SafeDESIGNER remote control is not shown correctly when using certain versions.
SafeDESIGNER SafePLC window or AsSafety can be used instead.
This affects a set of following versions:
SLX Upgrade >=V1.10.2.x, Safety Release 1.10, SafeDESIGNER >=V4.2.3
and AR B4.26 to C4.26 or C4.33 to E4.33
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59370_1.fw(324)

Version 1.10.1.2:

ID: 487890
PhysicalStateChannels missing on X20SLX842
PhysicalStateChannels where not available on X20SLX842 module.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 491990 / Support ID: 400193973
SLXbootState 54
SLXbootState never reached value 54 "SafeRUN" although SLX booted correctly.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 495375
problem during boot
It could happen sporadically (usually only if no valid project was available on the SLX) that SLX entered failsafe state immediately after bootup (sometimes with logger message 98818).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 495585
Update online help to V1.103
Update online help to V1.103
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59370_1.fw(322)

Version 1.10.1.0:

ID: 491660
safety response time lengthens to 1.5 seconds
Caused by an error in the firmware of the X20SLX modules with safety digital outputs, the response time is 1.5 seconds in a safety point of view. The error was fixed with firmware 321, which is part of this upgrade.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59370_1.fw(321)

Version 1.10.0.3:

ID: 485260
first official release
first official release, requires SafeDESIGNER 4.2.1 or higher
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59370_1.fw(320)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.10.10.3 * 31.07.2019 6 MB EXE AS4_HW_X20SLX402.exe
Popis V4.1 HW Upgrade (X20SLX402)

Revision information X20cSLX402

Version 1.10.10.3:

ID: 626175
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 635320 / Support ID: 400280438, 400278830, 400284804
fix logger entry 123622
SLX didn't enter RUN state and logger number 123622 was entered when using 10 other safety modules.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61968_1.fw(330)

Version 1.10.10.1:

ID: 635320 / Support ID: 400280438, 400278830
fix logger entry 123622
SLX didn't enter RUN state and logger number123622 was entered when using 10 other safety modules.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 637055
new AR targets
support new AR targets X20CPx68x and xPC22xx
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61968_1.fw(330)

Version 1.10.10.0:

ID: 626175
safety response time
The check of the network transmission time of cyclic data tolerated values up to 12ms higher than configured by the parameters "safe data duration"/"additional tolerated packet loss".
This could lead to an increased safety responsetime.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61968_1.fw(330)

Version 1.10.9.0:

ID: 618250
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61968_1.fw(330)

Version 1.10.5.0:

ID: 580755
logger message 106773
Fix for logger message 106773 "Parameter checksum sizes do not match".
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61968_1.fw(326)

Version 1.10.4.1:

ID: 595830
First official upgrade
First official upgrade
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:No
Firmware: 1\61968_1.fw(326)