DWL@DWL10000285699
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
1.10.12.0 | * | 16.04.2021 | 2 MB | EXE | AS4_HW_X20ST4492.exe | |
Popis |
V4.0 HW Upgrade (X20ST4492) Revision information X20ST4492 Version 1.10.12.0: ID: 710675 Timing of module internal communication updated The timing of the module internal communication was updated. Sporadic errors 98818, 119317, 99348, 102914, 99350 no longer occur. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 710845 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\46105_1.fw(334) Version 1.10.11.0: ID: 692730 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692635 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(333) Version 1.10.10.1: ID: 669930 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(331) Version 1.10.10.0: ID: 622665 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(331) Version 1.10.9.1: ID: 643235 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330) Version 1.10.9.0: ID: 618285 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330) Version 1.10.1.5: ID: 585625 User configurable calculation of the input value during internal tests also in AS 3.x User configurable calculation of the input value during internal tests also in AS 3.x Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 585630 SafeThrSelector_0506_Bitx not working - Fix in AS 3.x The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.1.1: ID: 533055 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533145 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533195 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: No Firmware changed: No ID: 536305 SafeThrSelector_0506_Bitx not working The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 539130 User configurable calculation of the input value during internal tests User configurable calculation of the input value during internal tests Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.0.1: ID: 470650 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470655 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(321) Version 1.9.0.0: ID: 404205 safety response time The safety response time is now depending on the configured filter. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302) Version 1.7.0.1: ID: 388465 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.7.0.0: ID: 372070 changed manual verion to 1.70 changed manual verion to 1.70 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.6.0.98: ID: 370680 / Support ID: 400107215 Violation of cycle time in PreOp with input filter 1ms Functions were rearranged in PreOp to comply with the cycle time for all filters. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 370690 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8. SafetyRelease 1.8 serves as basis for the backward compatibility Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(311) Version 1.6.0.7: ID: 339295 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.5: ID: 335505 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335510 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.3: ID: 332250 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.2: ID: 328595 Correction for responsetimecalculator Correction of parameters used for the calculation of the worstcase responsetime in Release 1.6 with the responsetimecalculator. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.1: ID: 314585 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.5: ID: 312420 added pindefinitions for EPLAN export added pindefinitions for EPLAN export Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.4: ID: 303410 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.0: ID: 293960 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.10.11.0 | * | 17.09.2020 | 1 MB | EXE | AS4_HW_X20ST4492.exe | |
Popis |
V4.0 HW Upgrade (X20ST4492) Revision information X20ST4492 Version 1.10.11.0: ID: 692730 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692635 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(333) Version 1.10.10.1: ID: 669930 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(331) Version 1.10.10.0: ID: 622665 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(331) Version 1.10.9.1: ID: 643235 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330) Version 1.10.9.0: ID: 618285 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330) Version 1.10.1.5: ID: 585625 User configurable calculation of the input value during internal tests also in AS 3.x User configurable calculation of the input value during internal tests also in AS 3.x Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 585630 SafeThrSelector_0506_Bitx not working - Fix in AS 3.x The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.1.1: ID: 533055 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533145 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533195 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: No Firmware changed: No ID: 536305 SafeThrSelector_0506_Bitx not working The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 539130 User configurable calculation of the input value during internal tests User configurable calculation of the input value during internal tests Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.0.1: ID: 470650 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470655 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(321) Version 1.9.0.0: ID: 404205 safety response time The safety response time is now depending on the configured filter. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302) Version 1.7.0.1: ID: 388465 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.7.0.0: ID: 372070 changed manual verion to 1.70 changed manual verion to 1.70 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.6.0.98: ID: 370680 / Support ID: 400107215 Violation of cycle time in PreOp with input filter 1ms Functions were rearranged in PreOp to comply with the cycle time for all filters. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 370690 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8. SafetyRelease 1.8 serves as basis for the backward compatibility Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(311) Version 1.6.0.7: ID: 339295 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.5: ID: 335505 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335510 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.3: ID: 332250 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.2: ID: 328595 Correction for responsetimecalculator Correction of parameters used for the calculation of the worstcase responsetime in Release 1.6 with the responsetimecalculator. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.1: ID: 314585 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.5: ID: 312420 added pindefinitions for EPLAN export added pindefinitions for EPLAN export Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.4: ID: 303410 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.0: ID: 293960 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.10.10.1 | * | 31.01.2020 | 2 MB | EXE | AS4_HW_X20ST4492.exe | |
Popis |
V4.0 HW Upgrade (X20ST4492) Revision information X20ST4492 Version 1.10.10.1: ID: 669930 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(331) Version 1.10.10.0: ID: 622665 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(331) Version 1.10.9.1: ID: 643235 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330) Version 1.10.9.0: ID: 618285 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330) Version 1.10.1.5: ID: 585625 User configurable calculation of the input value during internal tests also in AS 3.x User configurable calculation of the input value during internal tests also in AS 3.x Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 585630 SafeThrSelector_0506_Bitx not working - Fix in AS 3.x The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.1.1: ID: 533055 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533145 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533195 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: No Firmware changed: No ID: 536305 SafeThrSelector_0506_Bitx not working The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 539130 User configurable calculation of the input value during internal tests User configurable calculation of the input value during internal tests Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.0.1: ID: 470650 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470655 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(321) Version 1.9.0.0: ID: 404205 safety response time The safety response time is now depending on the configured filter. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302) Version 1.7.0.1: ID: 388465 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.7.0.0: ID: 372070 changed manual verion to 1.70 changed manual verion to 1.70 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.6.0.98: ID: 370680 / Support ID: 400107215 Violation of cycle time in PreOp with input filter 1ms Functions were rearranged in PreOp to comply with the cycle time for all filters. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 370690 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8. SafetyRelease 1.8 serves as basis for the backward compatibility Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(311) Version 1.6.0.7: ID: 339295 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.5: ID: 335505 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335510 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.3: ID: 332250 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.2: ID: 328595 Correction for responsetimecalculator Correction of parameters used for the calculation of the worstcase responsetime in Release 1.6 with the responsetimecalculator. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.1: ID: 314585 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.5: ID: 312420 added pindefinitions for EPLAN export added pindefinitions for EPLAN export Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.4: ID: 303410 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.0: ID: 293960 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.10.9.1 | * | 16.05.2019 | 2 MB | EXE | AS4_HW_X20ST4492.exe | |
Popis |
V4.0 HW Upgrade (X20ST4492) Revision information X20ST4492 Version 1.10.9.1: ID: 643235 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330) Version 1.10.9.0: ID: 618285 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330) Version 1.10.1.5: ID: 585625 User configurable calculation of the input value during internal tests alsoin AS 3.x User configurable calculation of the input value during internal testsalso in AS 3.x Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 585630 SafeThrSelector_0506_Bitx not working - Fix in AS 3.x The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.1.1: ID: 533055 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533145 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533195 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: No Firmware changed: No ID: 536305 SafeThrSelector_0506_Bitx not working The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 539130 User configurable calculation of the input value during internal tests User configurable calculation of the input value during internal tests Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.0.1: ID: 470650 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470655 Support of release 1.10 includingopenSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(321) Version 1.9.0.0: ID: 404205 safety response time The safety response time is now depending on the configured filter. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302) Version 1.7.0.1: ID: 388465 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.7.0.0: ID: 372070 changed manual verion to 1.70 changed manual verion to 1.70 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.6.0.98: ID: 370680 / Support ID: 400107215 Violation of cycle time in PreOp with input filter 1ms Functions were rearranged in PreOp to comply with the cycle time for all filters. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 370690 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8. SafetyRelease 1.8 serves as basis for the backward compatibility Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(311) Version 1.6.0.7: ID: 339295 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.5: ID: 335505 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335510 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.3: ID: 332250 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.2: ID: 328595 Correction for responsetimecalculator Correction of parameters used for the calculation of the worstcase responsetime in Release 1.6 with the responsetimecalculator. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.1: ID: 314585 Adaption of module configuration file release 1.6 Adaption ofmodule configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.5: ID: 312420 added pindefinitions for EPLAN export added pindefinitions for EPLAN export Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.4: ID: 303410 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.0: ID: 293960 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.10.9.0 | * | 08.11.2018 | 2 MB | EXE | AS4_HW_X20ST4492.exe | |
Popis |
V4.0 HW Upgrade (X20ST4492) Revision information X20ST4492 Version 1.10.9.0: ID: 618285 logger entry 112174, 108078 Loggerentry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330) Version 1.10.1.5: ID: 585625 User configurable calculation of the input value during internal tests alsoin AS 3.x User configurable calculation of the input value during internal tests alsoin AS 3.x Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 585630 SafeThrSelector_0506_Bitx not working - Fix in AS 3.x The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.1.1: ID: 533055 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533145 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: No Configuration description changed:No Firmware changed: No ID: 533195 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: No Firmware changed: No ID: 536305 SafeThrSelector_0506_Bitx not working The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 539130 User configurable calculation of the input value during internal tests User configurable calculation of the input value during internal tests Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.0.1: ID: 470650 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470655 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5with easier parametrizationof timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(321) Version 1.9.0.0: ID: 404205 safety response time The safety response time is now depending on the configured filter. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302) Version 1.7.0.1: ID: 388465 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.7.0.0: ID:372070 changed manual verion to 1.70 changed manual verion to 1.70 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.6.0.98: ID: 370680 / Support ID: 400107215 Violation of cycle time in PreOp with input filter 1ms Functions were rearranged in PreOp to comply with the cycle time for all filters. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 370690 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8. SafetyRelease 1.8 serves as basis for the backward compatibility Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(311) Version 1.6.0.7: ID: 339295 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.5: ID: 335505 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335510 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.3: ID: 332250 The module also supports SafetyRelease 1.7 Starting with this version, the module also supportsSafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.2: ID: 328595 Correction for responsetimecalculator Correction of parameters used for the calculation of the worstcase responsetime in Release 1.6 with the responsetimecalculator. Channeldescription changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.1: ID: 314585 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.5: ID: 312420 added pindefinitions for EPLAN export added pindefinitions for EPLAN export Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.4: ID: 303410 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.0: ID: 293960 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.10.1.5 | * | 05.10.2018 | 2 MB | EXE | AS4_HW_X20ST4492.exe | |
Popis |
V4.0 HW Upgrade (X20ST4492) Revision information X20ST4492 Version 1.10.1.5: ID: 585625 User configurable calculation of the input value during internal tests alsoin AS 3.x User configurable calculation of the input value during internal tests alsoin AS 3.x Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 585630 SafeThrSelector_0506_Bitx not working - Fix in AS 3.x The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.1.1: ID: 533055 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533145 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533195 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: No Firmware changed: No ID: 536305 SafeThrSelector_0506_Bitx not working The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitxis not working. Subsequently always the first thresholds are used. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 539130 User configurable calculation of the input value during internal tests User configurable calculation of theinput value during internal tests Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.0.1: ID: 470650 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470655 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(321) Version 1.9.0.0: ID: 404205 safety response time The safety response time is now depending on the configured filter. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302) Version 1.7.0.1: ID: 388465 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.7.0.0: ID: 372070 changed manual verion to 1.70 changed manual verion to 1.70 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.6.0.98: ID: 370680 / Support ID: 400107215 Violation of cycle time in PreOp with input filter 1ms Functions were rearranged in PreOp to comply with the cycle time for all filters. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 370690 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8. SafetyRelease 1.8 serves as basis for thebackward compatibility Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(311) Version 1.6.0.7: ID: 339295 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.5: ID: 335505 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335510 / Support ID: 400083263 unlock of SafeModuleIDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.3: ID:332250 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel descriptionchanged: No Configuration description changed: No Firmware changed:No Firmware: 3\46105_1.fw(295) Version 1.6.0.2: ID: 328595 Correction for responsetimecalculator Correction of parameters used for the calculation of the worstcase responsetime in Release 1.6 with the responsetimecalculator. Channel description changed: No Configurationdescription changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.1: ID: 314585 Adaption of module configuration file release 1.6 Adaption of module configuration file release1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.5: ID: 312420 added pindefinitions for EPLAN export added pindefinitions for EPLAN export Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.4: ID: 303410 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.0: ID: 293960 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.10.1.1 | * | 28.07.2017 | 2 MB | EXE | AS4_HW_X20ST4492.exe | |
Popis |
V4.0 HW Upgrade (X20ST4492) Revision information X20ST4492 Version 1.10.1.1: ID: 533055 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed:No Firmware changed: No ID: 533145 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533195 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: No Firmware changed: No ID: 536305 SafeThrSelector_0506_Bitx not working The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 539130 User configurable calculation of the input value during internal tests User configurable calculation of the input value during internal tests Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.0.1: ID: 470650 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed:No Configuration description changed: No Firmware changed: No ID: 470655 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295),4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(321) Version 1.9.0.0: ID: 404205 safety response time The safety response timeis now depending on the configured filter. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302) Version 1.7.0.1: ID: 388465 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.7.0.0: ID: 372070 changed manual verionto 1.70 changed manual verion to 1.70 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.6.0.98: ID: 370680 / Support ID: 400107215 Violation of cycle time in PreOp with input filter 1ms Functions were rearranged in PreOp to comply with the cycle time for all filters. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 370690 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8. SafetyRelease 1.8 serves as basis for the backward compatibility Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(311) Version 1.6.0.7: ID: 339295 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.5: ID: 335505 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335510 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.3: ID: 332250 The module also supports SafetyRelease 1.7 Startingwith this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 3\46105_1.fw(295) Version 1.6.0.2: ID: 328595 Correction for responsetimecalculator Correction of parameters used for the calculation of the worstcase responsetime in Release 1.6 with the responsetimecalculator. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.1: ID: 314585 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.5: ID: 312420 added pindefinitions for EPLAN export added pindefinitions for EPLAN export Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.4: ID: 303410 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.0: ID: 293960 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) |