DWL@DWL10000304810
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
1.4.0.0 | * | 17.02.2023 | 1 MB | EXE | AS4_HW_X20DO6322.exe | |
Popis |
V4.0 HW Upgrade (X20DO6322) Revision information X20DO6322 Version 1.4.0.0: ID: 765120 / Support ID: 400390300 Failure ModulOK If this module starting with revision K0 is operated behind a bus controller, the network status fails every 10 s (for one X2X cycle). This failure hasthe following effects. - Local X2X bus: No effect - POWERLINK / Modbus TCP / PROFIBUS / CAN I/O: No effect - CANopen: "Object 0x30B2 Network status OK" fails sporadically. - OPC-UA: Flag ModuleOK of the respective X2X module may fail sporadically - EthernetIP / PROFINET / Sercos3 / EtherCAT: - No effect directly on the bus controller. - The network status is transferred as BYTE at the beginning of the cyclicdata of the respective X2X station (ModuleOK) and can be evaluated by the respective remote station (data point mapping and evaluation within the application). - Setpoint: 0xF5, in the event of error: 0xF1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7064_1.fw(560), 1\7064_30.fw(220), 1\7064_5.fw(819) Version 1.3.0.0: ID: 746820 Support new HW variant 30 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7064_1.fw(560), 1\7064_30.fw(210), 1\7064_5.fw(819) Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channeldescription changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.4.0: ID: 467195 Module documentation revised Data sheet V 3.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.3.0: ID: 434580 / Support ID: 400155699 Documentation changed Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.4: ID: 395570 Enhancement online-help files Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.3: ID: 393390 Enhancements packed data point for outputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.2: ID: 366294 APROL entries revised Datapoint OSPValid corrected Channel descriptionchanged: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.1: ID: 344655 Extension of documentation Description of additional LED condition for OSP mode. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.0: ID: 250710 Additional function model "OSP mode" OSP - Output Set Predefined In OSP mode, the user defines the output behavior in case of connection loss between PLC and module. In doing so the power supply of the module mustbe assured. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.1.0: ID: 217470 Adaptation UART Re-Init Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\7064_1.fw(560), 1\7064_5.fw(800) Version 1.0.0.1: ID: 211570 Display correction in IO-Map on SGC Targets Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(530) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.3.0.0 | * | 26.04.2022 | 802 KB | EXE | AS4_HW_X20DO6322.exe | |
Popis |
V4.0 HW Upgrade (X20DO6322) Revision information X20DO6322 Version 1.3.0.0: ID: 746820 Support new HW variant 30 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7064_1.fw(560), 1\7064_30.fw(210), 1\7064_5.fw(819) Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.4.0: ID: 467195 Module documentation revised Data sheet V 3.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.3.0: ID: 434580 / Support ID: 400155699 Documentation changed Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.4: ID: 395570 Enhancement online-help files Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.3: ID: 393390 Enhancements packed data point for outputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.2: ID: 366294 APROL entries revised Datapoint OSPValid corrected Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.1: ID: 344655 Extension of documentation Description of additional LED condition for OSP mode. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.0: ID: 250710 Additional function model "OSP mode" OSP - Output Set Predefined In OSP mode, the user defines the output behavior incase of connection loss between PLC and module. In doing so the power supply of the module must be assured. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.1.0: ID: 217470 Adaptation UART Re-Init Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7064_1.fw(560), 1\7064_5.fw(800) Version 1.0.0.1: ID: 211570 Display correction in IO-Map on SGC Targets Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(530) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.2.0.0 | * | 23.07.2021 | 719 KB | EXE | AS4_HW_X20DO6322.exe | |
Popis |
V4.0 HW Upgrade (X20DO6322) Revision information X20DO6322 Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.4.0: ID: 467195 Module documentation revised Data sheet V 3.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.3.0: ID: 434580 / Support ID: 400155699 Documentation changed Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.4: ID: 395570 Enhancement online-help files Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.3: ID: 393390 Enhancementspacked data point for outputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.2: ID: 366294 APROL entries revised Datapoint OSPValid corrected Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.1: ID: 344655 Extension of documentation Description of additional LED condition for OSP mode. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.0: ID: 250710 Additional function model "OSP mode" OSP - Output Set Predefined In OSP mode, the user defines the output behavior in case of connection loss between PLC and module. In doing so the power supply of the modulemust be assured. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.1.0: ID: 217470 Adaptation UART Re-Init Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7064_1.fw(560), 1\7064_5.fw(800) Version 1.0.0.1: ID: 211570 Display correction in IO-Map on SGC Targets Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(530) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.1.0.0 | * | 25.10.2019 | 715 KB | EXE | AS4_HW_X20DO6322.exe | |
Popis |
V4.0 HW Upgrade (X20DO6322) Revision information X20DO6322 Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.4.0: ID: 467195 Module documentation revised Data sheet V 3.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.3.0: ID: 434580 / Support ID: 400155699 Documentation changed Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.4: ID: 395570 Enhancement online-help files Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.3: ID: 393390 Enhancements packed data point for outputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.2: ID: 366294 APROL entries revised Datapoint OSPValid corrected Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.1: ID: 344655 Extension of documentation Description of additional LED condition for OSP mode. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.0: ID: 250710 Additional function model "OSP mode" OSP - Output Set Predefined In OSP mode, the user defines the output behavior in case of connection loss between PLC and module. In doing so the power supply of the module must be assured. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.1.0: ID: 217470 Adaptation UART Re-Init Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7064_1.fw(560), 1\7064_5.fw(800) Version 1.0.0.1: ID: 211570 Display correction in IO-Map on SGC Targets Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(530) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.0.4.0 | * | 07.03.2016 | 734 KB | EXE | AS4_HW_X20DO6322.exe | |
Popis |
V4.0 HW Upgrade (X20DO6322) Revision information X20DO6322 Version 1.0.4.0: ID: 467195 Module documentation revised Data sheet V 3.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.3.0: ID: 434580 / Support ID: 400155699 Documentation changed Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.4: ID: 395570 Enhancement online-help files Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.3: ID: 393390 Enhancements packed data point for outputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.2: ID: 366294 APROL entries revised Datapoint OSPValid corrected Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.1: ID: 344655 Extension of documentation Description of additional LED condition for OSP mode. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.2.0: ID: 250710 Additional function model "OSP mode" OSP - Output Set Predefined In OSP mode, the user defines the output behavior in case of connection loss between PLC and module. In doing so the power supply of the module must be assured. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7064_1.fw(560), 1\7064_5.fw(819) Version 1.0.1.0: ID: 217470 Adaptation UART Re-Init Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7064_1.fw(560), 1\7064_5.fw(800) Version 1.0.0.1: ID: 211570 Display correction in IO-Map on SGC Targets Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\7064_1.fw(530) |