DWL@DWL10000416647
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
2.3.0.0 | * | 26.04.2021 | 3 MB | EXE | AS3.0_HW_X67SM2436.exe | |
Popis |
V3.0 HW Upgrade (X67SM2436) Revision information X67SM2436 Version 2.3.0.0: ID: 720265 support for HW-variant 6 Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 722855 FullstepThreshold limited on overflow Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 724055 Module documentation revised Data sheet V2.70 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(230), 1\7627_5.fw(230), 1\7627_6.fw(230) Version 2.2.0.0: ID: 639920 Support for mappMotion Channel description changed: No Configuration descriptionchanged: No Firmware changed: No ID: 671940 Module documentation revised Data sheet V2.62 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(210), 1\7627_5.fw(210) Version 1.6.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.5.0.1: ID:500570 / Support ID: 400198833, 400238752 hwx correction Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(210), 1\7627_5.fw(210) Version 1.5.0.0: ID: 551040 / Support ID: 400225909 acyclic read access to the registers for holding/rated/maximum current Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 562760 Module documentation revised Data sheet V2.50 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(210), 1\7627_5.fw(210) Version 1.4.1.2: ID: 500570 / Support ID: 400198833 hwx correction Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(200), 1\7627_5.fw(200) Version 1.4.1.1: ID: 474735 Motion Wizzard revised In AS 4.x, the aged library "AsString" won’t be added to a AS project anymore. The "AsBrStr" will be used by the Motion instead. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(200), 1\7627_5.fw(200) Version 1.4.1.0: ID: 477705 Module documentation revised Data sheet V2.31 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(200), 1\7627_5.fw(200) Version 1.4.0.1: ID: 469960 / Support ID: 400179666 default value in hwx adjusted Default value for "Used Encoder Motor x" is set to the original value - (only in hwx, functional model Motion Configuration) Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(200), 1\7627_5.fw(200) Version 1.4.0.0: ID: 454735 Minimum speed for stall detection is now configurable Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 458810 Module documentation revised Datasheet2.30 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(200), 1\7627_5.fw(200) Version 1.3.1.1: ID: 400920 Function model Ramp: new mode Mode -120: Set home position Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 400930 Cycle time of MPGen edjustable Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 406960 Corrected a problem in HWX file Channel description changed: No Configuration description changed: No Firmware changed: No ID: 406990 Corrected HWC entry Channel description changed: No Configuration description changed: No Firmware changed: No ID: 407350 Corrected a problem in HWX file Channel description changed: No Configuration description changed: No Firmware changed: No ID: 426495 extended HWX file Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(100) Version 1.3.1.0: ID: 367180 / Support ID: 400126239 Fixed a bug in the encoder emulation Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(22) Version 1.2.3.0: ID: 323200 Extension of EPLAN data Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 326395 Wrong description corrected Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(20) Version 1.2.2.0: ID: 180555 Upgrade does not work with old HW-Variants (HW2, HW3) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 310075 Module bootup timeout configured Channel description changed: No Configuration description changed:Yes Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(20) Version 1.2.1.0: ID: 272550 Ramp mode: Wrong configuratin for referencing speed is possible Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 272565 / Support ID: 400051695 The ACOPOSMicro doesn't switch in switched on with a customer motor at rampmode Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7627_1.fw(16), 1\7627_2.fw(13), 1\7627_3.fw(13), 1\7627_4.fw(20) Version 1.1.1.2: ID: 256440 Modul informations were not longer shown Modul informations weren't shown for Automation Runtime versiones > AR A3.08. This has been corrected. Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(13), 1\7627_3.fw(13), 1\7627_4.fw(19) Version 1.1.1.1: ID: 255900 Customer-specific expansion of hardware description file This upgrade has no impact on the Automation Studio and the standard version of the FieldbusDESIGNER Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(13), 1\7627_3.fw(13), 1\7627_4.fw(19) Version 1.1.1.0: ID: 229515 / Support ID: 400043902 X67SM2436 changes without problems in the "Switched On" state Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7627_1.fw(16), 1\7627_2.fw(13), 1\7627_3.fw(13), 1\7627_4.fw(19) Version 1.0.0.2: ID: 193760 / Support ID: 400013731 From the revision 1.0.0.2 the Functionmodel Ramp works on SGC Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(13), 1\7627_3.fw(13), 1\7627_4.fw(17) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.2.0.0 | * | 17.12.2019 | 4 MB | EXE | AS3.0_HW_X67SM2436.exe | |
Popis |
V3.0 HW Upgrade (X67SM2436) Revision information X67SM2436 Version 2.2.0.0: ID: 639920 Support for mappMotion Channel description changed: No Configuration description changed: No Firmware changed: No ID: 671940 Module documentation revised Data sheet V2.62 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(210), 1\7627_5.fw(210) Version 1.6.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.5.0.1: ID: 500570 / Support ID: 400198833, 400238752 hwx correction Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware:1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(210), 1\7627_5.fw(210) Version 1.5.0.0: ID: 551040 / Support ID: 400225909 acyclic read access to the registers for holding/rated/maximum current Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 562760 Module documentation revised Data sheet V2.50 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(210), 1\7627_5.fw(210) Version 1.4.1.2: ID: 500570 / Support ID: 400198833 hwx correction Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(200), 1\7627_5.fw(200) Version 1.4.1.1: ID: 474735 Motion Wizzard revised In AS 4.x, the aged library "AsString" won’t be added to a AS project anymore. The "AsBrStr" will be used by the Motion instead. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(200), 1\7627_5.fw(200) Version 1.4.1.0: ID: 477705 Module documentation revised Data sheet V2.31 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(200), 1\7627_5.fw(200) Version 1.4.0.1: ID: 469960 / Support ID: 400179666 default value in hwx adjusted Default value for "Used Encoder Motor x" is setto the original value - (only in hwx, functional model Motion Configuration) Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(200), 1\7627_5.fw(200) Version 1.4.0.0: ID: 454735 Minimum speed for stall detection is now configurable Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 458810 Module documentation revised Datasheet2.30 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(200), 1\7627_5.fw(200) Version 1.3.1.1: ID: 400920 Function model Ramp: new mode Mode -120: Set home position Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 400930 Cycle time of MPGen edjustable Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 406960 Corrected a problem in HWX file Channel description changed: No Configuration description changed: No Firmware changed: No ID: 406990 Corrected HWC entry Channel description changed: No Configuration description changed: No Firmware changed: No ID: 407350 Corrected a problem in HWX file Channel description changed: No Configuration description changed: No Firmware changed: No ID: 426495 extended HWX file Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(100) Version 1.3.1.0: ID: 367180 / Support ID: 400126239 Fixed a bug in the encoder emulation Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(22) Version1.2.3.0: ID: 323200 Extension of EPLAN data Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 326395 Wrong description corrected Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(20) Version 1.2.2.0: ID: 180555 Upgrade does not work with old HW-Variants (HW2, HW3) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 310075 Module bootup timeout configured Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(20) Version 1.2.1.0: ID: 272550 Ramp mode: Wrong configuratin for referencing speed is possible Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 272565 / Support ID: 400051695 The ACOPOSMicro doesn't switch in switched on with a customer motor at rampmode Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\7627_1.fw(16), 1\7627_2.fw(13), 1\7627_3.fw(13), 1\7627_4.fw(20) Version 1.1.1.2: ID: 256440 Modul informations were not longer shown Modul informations weren't shown for Automation Runtime versiones > AR A3.08. This has been corrected. Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(13), 1\7627_3.fw(13), 1\7627_4.fw(19) Version 1.1.1.1: ID: 255900 Customer-specific expansion of hardware description file This upgrade has no impact on the Automation Studio and the standard version of the FieldbusDESIGNER Channel description changed: No Configuration description changed: Yes Firmware changed:No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(13), 1\7627_3.fw(13), 1\7627_4.fw(19) Version 1.1.1.0: ID: 229515 / Support ID: 400043902 X67SM2436 changes without problems in the "Switched On" state Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7627_1.fw(16), 1\7627_2.fw(13), 1\7627_3.fw(13), 1\7627_4.fw(19) Version 1.0.0.2: ID: 193760 / Support ID: 400013731 From the revision 1.0.0.2 the Functionmodel Ramp works on SGC Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(13), 1\7627_3.fw(13), 1\7627_4.fw(17) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.5.0.0 | * | 03.11.2017 | 4 MB | EXE | AS3.0_HW_X67SM2436.exe | |
Popis |
V3.0 HW Upgrade (X67SM2436) Revision information X67SM2436 Version 1.5.0.0: ID: 551040 / Support ID: 400225909 acyclic read access to the registers for holding/rated/maximum current Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 562760 Module documentation revised Data sheet V2.50 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(210), 1\7627_5.fw(210) Version 1.4.1.2: ID: 500570 / Support ID: 400198833 hwx correction Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(200), 1\7627_5.fw(200) Version 1.4.1.1: ID: 474735 Motion Wizzard revised In AS 4.x, the aged library "AsString"won’t be added to a AS project anymore. The "AsBrStr" will be used by the Motion instead. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(200), 1\7627_5.fw(200) Version1.4.1.0: ID: 477705 Module documentation revised Data sheet V2.31 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(200), 1\7627_5.fw(200) Version 1.4.0.1: ID: 469960 / Support ID: 400179666 default value in hwx adjusted Default value for "Used Encoder Motor x" is set to the original value - (only in hwx, functional model Motion Configuration) Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(200), 1\7627_5.fw(200) Version 1.4.0.0: ID: 454735 Minimum speed for stall detection is now configurable Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 458810 Module documentation revised Datasheet2.30 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(200), 1\7627_5.fw(200) Version 1.3.1.1: ID: 400920 Function model Ramp: new mode Mode -120: Set home position Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 400930 Cycle time of MPGen edjustable Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 406960 Corrected a problem in HWX file Channel description changed: No Configuration description changed: No Firmware changed: No ID: 406990 Corrected HWC entry Channel description changed: No Configuration description changed: No Firmware changed: No ID: 407350 Corrected a problem in HWX file Channel description changed: No Configuration description changed: No Firmware changed: No ID: 426495 extended HWX file Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(100) Version 1.3.1.0: ID: 367180 / Support ID: 400126239 Fixed a bug in the encoderemulation Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(22) Version 1.2.3.0: ID: 323200 Extension of EPLAN data Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 326395 Wrong description corrected Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(20) Version 1.2.2.0: ID: 180555 Upgrade does not work with old HW-Variants (HW2, HW3) Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 310075 Module bootup timeout configured Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(14), 1\7627_3.fw(14), 1\7627_4.fw(20) Version 1.2.1.0: ID: 272550 Ramp mode: Wrong configuratin for referencing speed is possible Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 272565 / Support ID: 400051695 The ACOPOSMicro doesn't switch in switched on with a customer motor at rampmode Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7627_1.fw(16), 1\7627_2.fw(13), 1\7627_3.fw(13), 1\7627_4.fw(20) Version 1.1.1.2: ID: 256440 Modul informations were not longer shown Modul informations weren't shown for Automation Runtime versiones > AR A3.08. This has been corrected. Channel description changed: Yes Configurationdescription changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(13), 1\7627_3.fw(13), 1\7627_4.fw(19) Version 1.1.1.1: ID: 255900 Customer-specific expansion of hardware description file This upgrade has no impact on the Automation Studio and the standardversionof the FieldbusDESIGNER Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(13), 1\7627_3.fw(13), 1\7627_4.fw(19) Version 1.1.1.0: ID: 229515 / Support ID: 400043902 X67SM2436 changeswithout problems in the "Switched On" state Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\7627_1.fw(16), 1\7627_2.fw(13), 1\7627_3.fw(13), 1\7627_4.fw(19) Version 1.0.0.2: ID: 193760 / Support ID: 400013731 From the revision 1.0.0.2 the Functionmodel Ramp works on SGC Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7627_1.fw(16), 1\7627_2.fw(13), 1\7627_3.fw(13), 1\7627_4.fw(17) |