V3.0 HW Upgrade (8I64xxxxxxx.00x-1)

DWL@DWL10000661198

Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.1.3.0 * 03.03.2022 12 MB EXE AS3.0_HW_8I64xxxxxxx.00x-1.exe
Popis V3.0 HW Upgrade (8I64xxxxxxx.00x-1)

Revision information 8I64xxxxxxx.00x-1.00x-1

Version 2.1.3.0:

ID: 723255 / Support ID: 400349926
OTR register changed to a signed value
OTR register gives back positive values for output torque and negative values for removed torque
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 746805 / Support ID: 400323219
External error detection revised
The error message EPF1 does not have to be acknowledged after a restart - even not if the external error detection is used in low active mode.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_10.fw(117), 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 2.1.2.0:

ID: 717925 / Support ID: 400342873
Initialisation of parameter BLC revised
The configuration of parameter BLC can be downloaded as shown in the configuration view.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_10.fw(116), 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 2.1.1.0:

ID: 704580
Parameter OTR revised
The unit of the monitoring parameter OTR is adjusted according to the information of the ACOPOSinverter X64 manual.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 704670
Module documentation revised
User manual V 1.20
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_10.fw(116), 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 2.1.0.0:

ID: 686360 / Support ID: 400319099, 400319667
Setpoint selection in Hz (LFR/RFR)reworked
The setpoint selection was reworked and it is now possible to input Hz and RPM values (Hz-Setpoint: LFR/RFR RPM-Setpoint: LFRD/RFRD)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 688575 / Support ID: 400321231
Data point StatusDigitalOutput01 revised (ACPi P64new)
The status data point wasused to display detected errors on the original product ACPi X64. The base product of the replacement ACPi P64new does not provide a similar error detection. Hence, all links for this bit have been removed for the ACPi P64new (This change does not have any effict on using an ACPi X64.)
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes
Firmware: 1\45284_10.fw(114), 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 2.0.0.0:

ID: 588475 / Support ID: 400248602
Datapoint CMI revised
Bit 1 (data point CMI) cannot be used via I/O mapping. The data point was eliminated from the I/O mapping.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 632215
Support for revised hardware variante
The ACOPOSinverter P64new is released as new hardware variant for the discontinued ACOPOSinverter X64.
The ACPOSinverter P64new supports all essential functions that have been available for the ACOPOSinverter X64. Further details about the deviations are collected in the migration document, which is added to the revised user manual.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 679665
Data point ACPi_ModuleID revised
The optional data point ACPi_ModuleID can be managed as UINT (instead of anUDINT) on the I/O mapping. This optimizes the communication behavior (cyclic part of X2X).
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_10.fw(114), 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.9.1:

ID: 515925
Internal revision
File history corrected
Channel description changed: No
Configuration description changed:No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.9.0:

ID: 466740
Function models renamed
no influence to technical behavior
Functions model "default" renamed to "Direct control"
Functions model "default (MotionConfiguration)" renamed to "ACP10SDC (MotionConfiguration)"
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 511480
Default values resored
Default parameter value for module supervision restored, in order to avoid problems during conversion of existing projects in future.
ATTENTION: If module was stored in an Automation Studio project using hardware file 1.3.8.5, ensure parameter module supervision to have the desired value after upgrading.

INFORMATION:
The demaged file V 1.3.8.5 was delivered by Automation Studio 4.2.5 bis 4.2.6(complete installation).
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.5:

ID: 380420 / Support ID: 400132814
View in System Designer revised
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 511590
Motion Wizzard revised
In AS 4.x, the aged library "AsString" won’t be added to a AS project anymore. The "AsBrStr" will be used by the Motion instead.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.1:

ID: 321155
General review of HW files
Missing texts/textparts in HW file for AS4.x restored.
Channeldescription changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 366700 / Support ID: 400126199
Using ACPi X64 with SGC-CPU in AS4
Adaption for Automation Studio 4; Configuration parameters can be download,when ACPi is used with SGC cpu.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.0:

ID: 329805
Change filter settings at Counter02
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.6.0:

ID: 300120
Configuration Download parameters "on change" added
Channel description changed: Yes
Configuration descriptionchanged: Yes
Firmware changed: Yes
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.5.0:

ID: 276485 / Support ID: 400074496
Timeout of AsIOAccRead() on ACPi X64
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes

ID: 291675
With the configuration "Download parameters = no" all inverter configurations will be retained now.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_2.fw(9), 1\45284_3.fw(9)

Version 1.3.4.0:

ID:276790 / Support ID: 400077929
Inverter configuration optimized
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_2.fw(8), 1\45284_3.fw(8)

Version 1.3.3.0:

ID: 274200
After installation of Upgrade 1.3.2.0 RevInfo appears two times in help
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(8), 1\45284_3.fw(8)

Version 1.3.2.0:

ID: 270825 /Support ID: 400074141
At startup a COF error could appear with version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(7), 1\45284_3.fw(7)

Version 1.3.1.0:

ID: 258760 / Support ID: 400065557
On 8I0IF109.200-1 with rev. B5 the relay does not work in standalone mode
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(5), 1\45284_3.fw(5)

Version 1.2.0.0:

ID: 246470 / Support ID: 400057134
The boottime of X64 takes 8-45 seconds
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\45284_2.fw(5), 1\45284_3.fw(5)

Version 1.1.0.2:

ID: 245955
Customer-specific expansion of hardware description file
This upgrade has no impact on the Automation Studio and the standard version of the FieldbusDESIGNER
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(4)

Version 1.0.5.0:

ID: 238280 / Support ID: 400049786 400049841 400050585 400051602 400052158 400054894
At startup a CFF error could appear
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(4), 1\45284_3.fw(4)

Version 1.0.0.0:

ID: 223865
Support for ACOPOSInverter X64
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(2)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.1.2.0 * 25.02.2021 12 MB EXE AS3.0_HW_8I64xxxxxxx.00x-1.exe
Popis V3.0 HW Upgrade (8I64xxxxxxx.00x-1)

Revision information 8I64xxxxxxx.00x-1.00x-1

Version 2.1.2.0:

ID: 717925 / Support ID: 400342873
Initialisation of parameter BLC revised
The configuration of parameter BLC can be downloaded as shown in the configuration view.
Channel description changed: No
Configuration description changed: Yes
Firmwarechanged: No
Firmware: 1\45284_10.fw(116), 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 2.1.1.0:

ID: 704580
Parameter OTR revised
The unit of the monitoring parameter OTR is adjusted according to the information of the ACOPOSinverter X64 manual.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 704670
Module documentation revised
User manual V 1.20
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_10.fw(116), 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 2.1.0.0:

ID: 686360 / Support ID: 400319099, 400319667
Setpoint selection in Hz (LFR/RFR) reworked
The setpoint selection was reworked and it is now possible to input Hz and RPM values (Hz-Setpoint: LFR/RFR RPM-Setpoint: LFRD/RFRD)
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes

ID: 688575 / Support ID: 400321231
Data point StatusDigitalOutput01 revised (ACPi P64new)
The status data point was used to display detected errors on the original product ACPi X64. The base product of the replacement ACPi P64new does not provide a similar error detection. Hence, all links for this bit have been removedfor the ACPi P64new (This change does not have any effict on using an ACPi X64.)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_10.fw(114), 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 2.0.0.0:

ID: 588475 / Support ID: 400248602
Datapoint CMI revised
Bit 1 (data point CMI) cannot be used via I/O mapping. The data point was eliminated from the I/O mapping.
Channel description changed: Yes
Configurationdescription changed: No
Firmware changed: No

ID: 632215
Support for revised hardware variante
The ACOPOSinverter P64new is releasedas new hardware variant for the discontinued ACOPOSinverter X64.
The ACPOSinverter P64new supports all essential functions that have been available for the ACOPOSinverter X64. Further details about the deviations are collected in the migration document, which is added to the revised user manual.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 679665
Data point ACPi_ModuleID revised
The optional data point ACPi_ModuleID can be managed as UINT (instead of anUDINT) on the I/O mapping. This optimizes the communication behavior (cyclicpart of X2X).
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_10.fw(114), 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.9.1:

ID: 515925
Internal revision
File history corrected
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.9.0:

ID: 466740
Function models renamed
no influence to technical behavior
Functions model "default" renamed to "Direct control"
Functions model "default (MotionConfiguration)" renamed to "ACP10SDC (MotionConfiguration)"
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 511480
Default values resored
Default parameter value for module supervision restored, in order to avoid problems during conversion of existing projects in future.
ATTENTION: If module was stored in an Automation Studio project using hardware file 1.3.8.5, ensure parameter module supervision to have the desired value after upgrading.

INFORMATION:
The demaged file V 1.3.8.5 was delivered by Automation Studio 4.2.5 bis 4.2.6(complete installation).
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.5:

ID: 380420 / Support ID: 400132814
View in System Designer revised
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 511590
Motion Wizzard revised
In AS 4.x, the aged library "AsString" won’t be added to a AS projectanymore. The "AsBrStr" will be used by the Motion instead.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.1:

ID: 321155
General review of HW files
Missing texts/textparts in HW file for AS4.x restored.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 366700 / Support ID: 400126199
Using ACPi X64 with SGC-CPU in AS4
Adaption for Automation Studio 4; Configuration parameters can be download,when ACPi is used with SGC cpu.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.0:

ID: 329805
Change filter settings at Counter02
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.6.0:

ID: 300120
Configuration Download parameters "on change" added
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.5.0:

ID: 276485 / Support ID: 400074496
Timeout of AsIOAccRead() on ACPi X64
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 291675
With the configuration "Download parameters = no" all inverter configurations will be retained now.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_2.fw(9), 1\45284_3.fw(9)

Version 1.3.4.0:

ID: 276790 / Support ID: 400077929
Inverter configuration optimized
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_2.fw(8), 1\45284_3.fw(8)

Version 1.3.3.0:

ID: 274200
After installation of Upgrade 1.3.2.0 RevInfo appears two times in help
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(8), 1\45284_3.fw(8)

Version 1.3.2.0:

ID: 270825 / Support ID: 400074141
At startup a COF error could appear with version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(7), 1\45284_3.fw(7)

Version 1.3.1.0:

ID: 258760 / Support ID: 400065557
On 8I0IF109.200-1 with rev. B5 the relay does not work in standalone mode
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(5), 1\45284_3.fw(5)

Version 1.2.0.0:

ID: 246470 / Support ID: 400057134
The boottime of X64 takes 8-45 seconds
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\45284_2.fw(5), 1\45284_3.fw(5)

Version 1.1.0.2:

ID: 245955
Customer-specific expansion of hardware description file
This upgrade has no impact on the Automation Studio and the standard version of the FieldbusDESIGNER
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(4)

Version 1.0.5.0:

ID:238280 / Support ID: 400049786 400049841 400050585 400051602 400052158 400054894
At startup a CFF error could appear
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(4), 1\45284_3.fw(4)

Version 1.0.0.0:

ID: 223865
Support for ACOPOSInverter X64
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(2)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.1.1.0 * 13.10.2020 12 MB EXE AS3.0_HW_8I64xxxxxxx.00x-1.exe
Popis V3.0 HW Upgrade (8I64xxxxxxx.00x-1)

Revision information 8I64xxxxxxx.00x-1

Version 2.1.1.0:

ID: 704580
Parameter OTR revised
The unit of the monitoring parameter OTR is adjusted according to the information of the ACOPOSinverter X64 manual.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 704670
Module documentation revised
User manual V 1.20
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_10.fw(116), 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 2.1.0.0:

ID: 686360 / Support ID: 400319099, 400319667
Setpoint selection in Hz (LFR/RFR) reworked
The setpoint selection was reworked and it is now possible to input Hz and RPM values (Hz-Setpoint: LFR/RFR RPM-Setpoint: LFRD/RFRD)
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes

ID: 688575 / Support ID: 400321231
Data point StatusDigitalOutput01 revised (ACPi P64new)
The status data point was used to display detected errors on the original product ACPi X64. The base product of the replacement ACPi P64new does not provide a similar error detection. Hence, all links for this bit have been removedfor the ACPi P64new (This change does not have any effict on using an ACPi X64.)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_10.fw(114), 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 2.0.0.0:

ID: 588475 / Support ID: 400248602
Datapoint CMI revised
Bit 1 (data point CMI) cannot be used via I/O mapping. The data point was eliminated from the I/O mapping.
Channel description changed: Yes
Configurationdescription changed: No
Firmware changed: No

ID: 632215
Support for revised hardware variante
The ACOPOSinverter P64new is releasedas new hardware variant for the discontinued ACOPOSinverter X64.
The ACPOSinverter P64new supports all essential functions that have been available for the ACOPOSinverter X64. Further details about the deviations are collected in the migration document, which is added to the revised user manual.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 679665
Data point ACPi_ModuleID revised
The optional data point ACPi_ModuleID can be managed as UINT (instead of anUDINT) on the I/O mapping. This optimizes the communication behavior (cyclicpart of X2X).
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_10.fw(114), 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.9.1:

ID: 515925
Internal revision
File history corrected
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.9.0:

ID: 466740
Function models renamed
no influence to technical behavior
Functions model "default" renamed to "Direct control"
Functions model "default (MotionConfiguration)" renamed to "ACP10SDC (MotionConfiguration)"
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 511480
Default values resored
Default parameter value for module supervision restored, in order to avoid problems during conversion of existing projects in future.
ATTENTION: If module was stored in an Automation Studio project using hardware file 1.3.8.5, ensure parameter module supervision to have the desired value after upgrading.

INFORMATION:
The demaged file V 1.3.8.5 was delivered by Automation Studio 4.2.5 bis 4.2.6(complete installation).
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.5:

ID: 380420 / Support ID: 400132814
View in System Designer revised
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 511590
Motion Wizzard revised
In AS 4.x, the aged library "AsString" won’t be added to a AS projectanymore. The "AsBrStr" will be used by the Motion instead.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.1:

ID: 321155
General review of HW files
Missing texts/textparts in HW file for AS4.x restored.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 366700 / Support ID: 400126199
Using ACPi X64 with SGC-CPU in AS4
Adaption for Automation Studio 4; Configuration parameters can be download,when ACPi is used with SGC cpu.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.0:

ID: 329805
Change filter settings at Counter02
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.6.0:

ID: 300120
Configuration Download parameters "on change" added
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.5.0:

ID: 276485 / Support ID: 400074496
Timeout of AsIOAccRead() on ACPi X64
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 291675
With the configuration "Download parameters = no" all inverter configurations will be retained now.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_2.fw(9), 1\45284_3.fw(9)

Version 1.3.4.0:

ID: 276790 / Support ID: 400077929
Inverter configuration optimized
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_2.fw(8), 1\45284_3.fw(8)

Version 1.3.3.0:

ID: 274200
After installation of Upgrade 1.3.2.0 RevInfo appears two times in help
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(8), 1\45284_3.fw(8)

Version 1.3.2.0:

ID: 270825 / Support ID: 400074141
At startup a COF error could appear with version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(7), 1\45284_3.fw(7)

Version 1.3.1.0:

ID: 258760 / Support ID: 400065557
On 8I0IF109.200-1 with rev. B5 the relay does not work in standalone mode
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(5), 1\45284_3.fw(5)

Version 1.2.0.0:

ID: 246470 / Support ID: 400057134
The boottime of X64 takes 8-45 seconds
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\45284_2.fw(5), 1\45284_3.fw(5)

Version 1.1.0.2:

ID: 245955
Customer-specific expansion of hardware description file
This upgrade has no impact on the Automation Studio and the standard version of the FieldbusDESIGNER
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(4)

Version 1.0.5.0:

ID:238280 / Support ID: 400049786 400049841 400050585 400051602 400052158 400054894
At startup a CFF error could appear
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(4), 1\45284_3.fw(4)

Version 1.0.0.0:

ID: 223865
Support for ACOPOSInverter X64
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(2)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.1.0.0 * 10.06.2020 12 MB EXE AS3.0_HW_8I64xxxxxxx.00x-1.exe
Popis V3.0 HW Upgrade (8I64xxxxxxx.00x-1)

Revision information 8I64xxxxxxx.00x-1

Version 2.1.0.0:

ID: 686360 / Support ID: 400319099, 400319667
Setpoint selection in Hz (LFR/RFR) reworked
The setpoint selection was reworked and it is now possible to input Hz and RPM values (Hz-Setpoint: LFR/RFR RPM-Setpoint: LFRD/RFRD)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 688575 / Support ID: 400321231
Data point StatusDigitalOutput01 revised(ACPi P64new)
The status data point was used to display detected errors on the original product ACPi X64. The base product of the replacement ACPi P64new does not provide a similar error detection. Hence, all links for this bit have been removedfor the ACPi P64new (This change does not have any effict onusing an ACPi X64.)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_10.fw(114), 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 2.0.0.0:

ID:588475 / Support ID: 400248602
Datapoint CMI revised
Bit 1 (data point CMI) cannot be used via I/O mapping. The data point was eliminated from the I/O mapping.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 632215
Support for revised hardware variante
The ACOPOSinverter P64new is released as newhardware variant for the discontinued ACOPOSinverter X64.
The ACPOSinverter P64new supports all essential functions that have been available for the ACOPOSinverter X64. Further details about the deviations are collected in the migration document, which is added to the revised user manual.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 679665
Data point ACPi_ModuleID revised
Theoptional data point ACPi_ModuleID can be managed as UINT (instead of an UDINT) on the I/O mapping. This optimizes the communication behavior (cyclic part of X2X).
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_10.fw(114), 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.9.1:

ID: 515925
Internal revision
File history corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.9.0:

ID: 466740
Function models renamed
no influence to technical behavior
Functions model "default" renamed to "Direct control"
Functions model "default (MotionConfiguration)" renamed to "ACP10SDC (MotionConfiguration)"
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 511480
Default values resored
Default parameter value for module supervision restored, in order to avoidproblems during conversion of existing projects in future.
ATTENTION: If module was stored in an Automation Studio project using hardware file 1.3.8.5, ensure parameter module supervision to have the desired value after upgrading.

INFORMATION:
The demaged file V 1.3.8.5 was delivered by AutomationStudio 4.2.5 bis 4.2.6 (complete installation).
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.5:

ID: 380420 / Support ID: 400132814
View in System Designer revised
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 511590
Motion Wizzard revised
In AS 4.x, the aged library "AsString" won’t be added to a AS project anymore. The "AsBrStr" will be used by the Motion instead.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.1:

ID: 321155
General review of HW files
Missing texts/textparts in HW file for AS4.x restored.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 366700 / Support ID: 400126199
Using ACPi X64 with SGC-CPU in AS4
Adaption for Automation Studio 4; Configuration parameters can be download,when ACPi is used with SGC cpu.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.0:

ID: 329805
Change filter settings at Counter02
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.6.0:

ID: 300120
Configuration Download parameters "on change" added
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.5.0:

ID: 276485 / Support ID: 400074496
Timeout of AsIOAccRead() on ACPi X64
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 291675
With the configuration "Download parameters = no" all inverter configurations will be retained now.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_2.fw(9), 1\45284_3.fw(9)

Version 1.3.4.0:

ID: 276790 / Support ID: 400077929
Inverter configuration optimized
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_2.fw(8), 1\45284_3.fw(8)

Version 1.3.3.0:

ID: 274200
After installation of Upgrade 1.3.2.0 RevInfo appears two times in help
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(8), 1\45284_3.fw(8)

Version 1.3.2.0:

ID: 270825 / Support ID: 400074141
At startup a COF error could appear with version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(7), 1\45284_3.fw(7)

Version 1.3.1.0:

ID: 258760 / Support ID: 400065557
On 8I0IF109.200-1 with rev. B5 the relay does not work in standalone mode
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(5), 1\45284_3.fw(5)

Version 1.2.0.0:

ID: 246470 / Support ID: 400057134
The boottime of X64 takes 8-45 seconds
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\45284_2.fw(5), 1\45284_3.fw(5)

Version 1.1.0.2:

ID: 245955
Customer-specific expansion of hardware description file
This upgrade has no impact on the Automation Studio and the standard version of the FieldbusDESIGNER
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:No
Firmware: 1\45284_2.fw(4)

Version 1.0.5.0:

ID: 238280/ Support ID: 400049786 400049841 400050585 400051602 400052158 400054894
At startup a CFF error could appear
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(4), 1\45284_3.fw(4)

Version 1.0.0.0:

ID: 223865
Support for ACOPOSInverter X64
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(2)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.0.0.0 * 05.03.2020 12 MB EXE AS3.0_HW_8I64xxxxxxx.00x-1.exe
Popis V3.0 HW Upgrade (8I64xxxxxxx.00x-1)

Revision information 8I64xxxxxxx.00x-1

Version 2.0.0.0:

ID: 588475 / Support ID: 400248602
Datapoint CMI revised
Bit 1 (data point CMI) cannot be used via I/O mapping. The data point was eliminated from the I/O mapping.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 632215
Support for revised hardware variante
TheACOPOSinverter P64new is released as new hardware variant for the discontinued ACOPOSinverter X64.
The ACPOSinverter P64new supports all essential functions that have been available for the ACOPOSinverter X64. Further details about the deviations are collected in the migration document, which is added to the revised user manual.
Channel description changed: No
Configurationdescription changed: Yes
Firmware changed: Yes

ID: 679665
Data point ACPi_ModuleID revised
The optional data point ACPi_ModuleID can be managed as UINT (instead of anUDINT) on the I/O mapping. This optimizes the communication behavior (cyclic part of X2X).
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_10.fw(113), 1\45284_2.fw(10), 1\45284_3.fw(10)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.3.9.1 * 30.01.2017 9 MB EXE AS3.0_HW_8I64xxxxxxx.00x-1.exe
Popis V3.0 HW Upgrade (8I64xxxxxxx.00x-1)

Revision information 8I64xxxxxxx.00x-1

Version 1.3.9.1:

ID: 515925
Internal revision
File history corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.9.0:

ID: 466740
Function models renamed
no influence to technical behavior
Functions model "default" renamed to "Direct control"
Functions model "default (MotionConfiguration)" renamed to "ACP10SDC (MotionConfiguration)"
Channel description changed: Yes
Configuration description changed: No
Firmware changed:No

ID: 511480
Default values resored
Default parameter value for module supervision restored, in order to avoid problems during conversion of existing projects in future.
ATTENTION: If module was stored in an Automation Studio project using hardware file 1.3.8.5, ensure parameter module supervision to have the desired value after upgrading.

INFORMATION:
The demaged file V 1.3.8.5 was delivered by Automation Studio 4.2.5 bis 4.2.6(complete installation).
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.5:

ID: 380420 / SupportID: 400132814
View in System Designer revised
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 511590
Motion Wizzard revised
In AS 4.x, the aged library "AsString" won’t be added to a AS project anymore. The "AsBrStr" will be used by the Motion instead.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.1:

ID: 321155
General review of HW files
Missing texts/textparts in HW file for AS4.x restored.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 366700 / Support ID: 400126199
Using ACPi X64 with SGC-CPU in AS4
Adaption for Automation Studio4; Configuration parameters can be download, when ACPi is used with SGC cpu.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.8.0:

ID: 329805
Change filter settings at Counter02
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.6.0:

ID: 300120
Configuration Downloadparameters "on change" added
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\45284_2.fw(10), 1\45284_3.fw(10)

Version 1.3.5.0:

ID: 276485 /Support ID: 400074496
Timeout of AsIOAccRead() on ACPi X64
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 291675
With the configuration "Download parameters = no" all inverter configurations will be retained now.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_2.fw(9), 1\45284_3.fw(9)

Version 1.3.4.0:

ID: 276790 / Support ID: 400077929
Inverter configuration optimized
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45284_2.fw(8), 1\45284_3.fw(8)

Version 1.3.3.0:

ID: 274200
After installationof Upgrade 1.3.2.0 RevInfo appears two times in help
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes
Firmware: 1\45284_2.fw(8), 1\45284_3.fw(8)

Version 1.3.2.0:

ID: 270825 / Support ID: 400074141
At startup a COF error could appear with version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(7), 1\45284_3.fw(7)

Version 1.3.1.0:

ID: 258760 / Support ID: 400065557
On 8I0IF109.200-1 with rev. B5 the relay does not work instandalone mode
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(5), 1\45284_3.fw(5)

Version 1.2.0.0:

ID: 246470 / Support ID: 400057134
The boottime of X64 takes 8-45 seconds
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\45284_2.fw(5), 1\45284_3.fw(5)

Version 1.1.0.2:

ID: 245955
Customer-specific expansion of hardware description file
This upgrade has no impact on the Automation Studio and the standard version of the FieldbusDESIGNER
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(4)

Version 1.0.5.0:

ID: 238280 / Support ID: 400049786 400049841 400050585 400051602 400052158 400054894
At startup a CFF error could appear
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45284_2.fw(4), 1\45284_3.fw(4)

Version 1.0.0.0:

ID: 223865
Support for ACOPOSInverter X64
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45284_2.fw(2)