Please choose country and language

General information
B&R ID code 0xB41D
Status indicators Safety status, interface status
Cooling and mounting type Cold plate mounting
Certifications
CE Yes
UL cULus E225616
Power conversion equipment
Functional safety Yes
DC bus connection
Voltage
Nominal 750 VDC
Variant
DC+, DC-, PE Cage clamp terminal block
Shield connection Yes (via cable gland)
Terminal connection cross sections
Flexible and fine-stranded wires
With wire end sleeves 0.25 to 10 mm²
Approbation data
UL/C-UL-US 24 to 8
CSA 24 to 8
Terminal cross sections (cable diameter) 14 to 21 mm (M32 cable grommet)
Max. line length 30 m
24 VDC power supply
Quantity 2
Input voltage 24 VDC -25% / +20%
Max. power consumption In preparation
Variant
24 VDC, COM, PE Cage clamp terminal block
Shield connection No
Terminal connection cross sections
Flexible and fine-stranded wires
With wire end sleeves 0.25 to 10 mm²
Approbation data
UL/C-UL-US 24 to 8
CSA 24 to 8
Terminal cross sections (cable diameter) 14 to 21 mm (M32 cable grommet)
Max. line length 30 m
Hybrid cable outlets
Quantity 4 (each with DC bus, 24 VDC, 2x enable, POWERLINK)
DC+ and DC- fuse protection
Type Blow-out fuse conforming to UL/CSA, ø 10 x 38 mm
Tripping characteristic Fast-acting
Rated current of fuse depending on ambient temperature
40°C In preparation
60°C 20 A
24 VDC fuse protection
Type Blade fuses conforming to UL/CSA
Tripping characteristic Fast-acting
Rated current of fuse depending on ambient temperature
40°C In preparation
60°C 15 A
Continuous power depending on rated current of fuse
DC+ and DC-
20 A 10.1 kW
24 VDC
15 A 240 W
Continuous current depending on rated current of fuse
DC+ and DC-
20 A 13.5 A<sub>eff</sub>
24 VDC
15 A 10.1 A
Continuous current of enable outputs Max. 500 mA
Reduction of continuous power depending on installation elevation
Starting at 500 m above sea level 10% per 1,000 m
Power dissipation with continuous power
DC+ and DC-
20 A In preparation
24 VDC
15 A In preparation
Protective measures
Overload protection
DC+ and DC- No (overload status can be retrieved via fieldbus)
24 VDC No (overload status can be retrieved via fieldbus)
Short circuit and ground fault protection
DC+ and DC- Yes
24 VDC Yes
Max. line length 30 m
Variant 15-pin male TYCO connector
24 VDC output
Quantity 2
Output voltage Depends on the 24 VDC supply
Continuous current Max. 8 A (max. 4 A per pin)
Fuse protection per pin
Type Blade fuses conforming to UL/CSA
Tripping characteristic Fast-acting
Rated current of fuse depending on ambient temperature
40°C 5 A
60°C 7.5 A
Protective measures
Overload-proof No (overload status can be retrieved via fieldbus)
Short-circuit proof Yes
Variant
24 VDC, COM Female M8 connector
Fieldbus
Type POWERLINK (V1/V2) 100BASE-T (ANSI/IEE 802.3)
Variant 1x internal 4-port hub, 1x internal 5-port hub; 4x 19-pin hybrid connector, 4x M12 female connector
Line length Max. 100 m between two stations (segment length)
Transfer rate 100 Mbit/s
Enable inputs
Quantity 2
Input voltage
Nominal 24 VDC
Maximum 30 VDC
Permissible input current Max. 2 A
Variant Cage clamp terminal block
Terminal connection cross sections
Flexible and fine-stranded wires
With plastic wire end sleeves 0.25 to 1.5 mm²
Approbation data
UL/C-UL-US 26 to 12
CSA -
Terminal cross sections (cable diameter) 5 to 9 mm (M16 cable grommet)
Max. line length 30 m
Operating conditions
Permissible mounting orientations
Hanging vertically Yes
Horizontal, face up Yes
Standing horizontally Yes
Installation elevation above sea level
Nominal 0 to 500 m
Maximum 4000 m
Pollution degree per EN 61800-5-1 2 (non-conductive pollution)
Overvoltage category per EN 61800-5-1 III
Degree of protection per EN 60529 IP65
Ambient conditions
Temperature
Operation
Nominal 5 to 40°C
Maximum 60°C
Storage -25 to 55°C
Transport -25 to 70°C
Relative humidity
Operation 5 to 85%, non-condensing
Storage 5 to 95%, non-condensing
Transport Max. 95% at 40°C
Mechanical properties
Dimensions
Width 293 mm
Height 328 mm
Depth 80 mm
Weight 7 kg
Material number:
8CVE28000HC00.00-1
Description:
  • Remote power distribution up to 30 kW using up to four hybrid cable outlets
  • Safeguards the DC bus
  • Diagnostics for all connections
  • Integrated connections for local I/O nodes
ACOPOSremote/ACOPOSmotor connection box, HV, IP65, cold plate mounting, 4x connections for hybrid cables, 2x 24 VDC Out
Mandatory Accessories
Fuse sets
8CXS000.0000-00 ACOPOSremote fuse set: 8x 10x38 mm fuse, 20 A, fast-acting
Optional Accessories
Accessory sets
8CXC000.0000-00 Accessory set: 1x slot cover for male hybrid connector
8CXC001.0000-00 ACOPOSremote accessory set: 2x bridge, 2-pin, fully isolated, 10 mm
8CXC001.0002-00 ACOPOSremote accessory set: 20x 2-pin bridge, fully isolated, 10 mm
8CXC001.0005-00 ACOPOSremote accessory set: 50x bridge 2-pin, fully isolated, grid 10 mm
8CXC001.000A-00 ACOPOSremote accessory set: 100x 2-pin bridge, fully isolated, 10 mm
8CXD000.0000-00 ACOPOSremote accessory set: 1x desiccant cartridge M36x1.5 for 8CVE connection box
8CXM001.0000-00 ACOPOSremote accessory set: 4x M6x25 mm hex socket head screw for 8CVE connection boxes
8CXM001.0002-00 ACOPOSremote accessory set: 20x M6x25 mm hex socket head screw for 8CVE connection boxes
8CXM001.0005-00 ACOPOSremote accessory set: 52x M6x25 mm hex socket head screw for 8CVE connection boxes
8CXM001.000A-00 ACOPOSremote accessory set: 100x M6x25 mm hex socket head screw for 8CVE connection boxes
Hybrid cables
8CCH0003.11110-1 Hybrid cable, length 3 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 2x 15-pin female TYCO connector, can be used in cable drag chains
8CCH0003.11130-1 Hybrid cable, length 3 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 2x 15-pin female TYCO connector, 1x connector insert rotated 180°, can be used in cable drag chains
8CCH0005.11110-1 Hybrid cable, length 5 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 2x 15-pin female TYCO connector, can be used in cable drag chains
8CCH0010.11110-1 Hybrid cable, length 10 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 2x 15-pin female TYCO connector, can be used in cable drag chains
8CCH0015.11110-1 Hybrid cable, length 15 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 2x 15-pin female TYCO connector, can be used in cable drag chains
8CCH0020.11110-1 Hybrid cable, length 20 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 2x 15-pin female TYCO connector, can be used in cable drag chains
Threaded caps
X67AC0M08 X67 M8 threaded caps, 50 pcs.
X67AC0M12 X67 M12 threaded caps, 50 pcs.
Automation Studio HW Upgrades Version (Date) Download
V3.0 HW Upgrade (8CVE28000HC00.00-1) EXE / 532 KB
Certificates Version (Date) Download
Declaration of conformity FS Servos PDF / 33 KB
Declaration of conformity Servos PDF / 163 KB
E225616 UL Certificate of Compliance ACOPOSremote PDF / 241 KB
TÜV-certificate - function "Safe Pulse Disabling" für ACOPOSremote ZIP / 675 KB
Documentation Version (Date) Download
Datasheet 8CVE28000HC00.00-1 PDF / 19 MB
Decentralized Motion Control User's Manual PDF / 60 MB
M-CAD (Mechan. Templates) Version (Date) Download
3D file STEP 8CVE28000HC00.00-1 ZIP / 9 MB

Please choose country and language

B&R Logo