DWL@DWL10000549324
Версия | Язык | Операционная система | Дата | Размер | Тип | Загрузка |
---|---|---|---|---|---|---|
1.14 | * | 22.04.2024 | 6 MB | ZIP | UPG_xPC3100_MTCX_V0114_EFI.zip | |
Описание |
xPC3100 Firmware Upgrade (MTCX, SDLT, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. 3. A Extended upgrade for the SDL4T Firmware is only necessary if an SDL4T firmware less than V01.00 is installed. 4. Starting with SDL4T Firmware V01.00, a downgrade to a version smaller then V01.00 is not possible. 5. Starting with SDL4T Firmware V01.00, a Automation Panel Firmware update for the SDL4R Firmware at least from V06.14 and HDBT Firmware at least from V01.00 is necessary. ---------------------------------------------------------------- Version 01.14 / 03/26/2024 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.14 NEW README.txt 01.14 NEW STARTUP.nsh 01.12 MTCXxPC3100.nsh 01.00 SDLTxPC3100.nsh 01.09 MTCXSVC.efi 21.30 NEW BRFSETUPD.efi 19.50 61320_0.fw 04.27 NEW 61321_0.fw 04.27 NEW 61322_0.fw 04.27 NEW 61333_0.fw 04.27 NEW 61334_0.fw 04.27 NEW 61335_0.fw 04.27 NEW 61336_0.fw 04.27 NEW 61337_0.fw 04.27 NEW 61159_0.fp (SDLT) 00.04 60620_0.fp (SDL4T) 01.04 60620i0.fp (SDL4TExt.) 01.04 Change(s) 61320_0.fw, 61321_0.fw, 61322_0.fw, 61333_0.fw, 61334_0.fw, 61335_0.fw, 61336_0.fw, 61337_0.fw (MTCX Firmware): - Bugfix: if a SDL3 Converter Box is installed on the onboard SDL interface, sporadic problems (slow response rate) of the ADI Control Center could occur. This behavior could only be observed with MTCX V4.26. - Bugfix: Display timings on PPC3100. Some display combinations could lead to image disturbances when changing the graphics modes or when activating/deactivating the screen saver. This behavior became more common observed with a 12.1in XGA display. The Power off/on and backlight off/on timings have been optimized. MTCXSVC: - Support for APC4100 family. ATTENTION! Possible upgrade problems and version dependency, see above. |
|||||
Версия | Язык | Операционная система | Дата | Размер | Тип | Загрузка |
1.13 | * | 11.09.2023 | 6 MB | ZIP | UPG_xPC3100_MTCX_V0113_EFI.zip | |
Описание |
xPC3100 Firmware Upgrade (MTCX, SDLT, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. 3. A Extended upgrade for the SDL4T Firmware is only necessary if an SDL4T firmware less than V01.00 is installed. 4. Starting with SDL4T Firmware V01.00, a downgrade to a version smaller then V01.00 is not possible. 5. Starting with SDL4T Firmware V01.00, a Automation Panel Firmware update for the SDL4R Firmware at least from V06.14 and HDBT Firmware at least from V01.00 is necessary. ---------------------------------------------------------------- Version 01.13 / 02/13/2023 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.13 NEW README.txt 01.13 NEW STARTUP.nsh 01.12 MTCXxPC3100.nsh 01.00 SDLTxPC3100.nsh 01.09 MTCXSVC.efi 19.52 BRFSETUPD.efi 19.50 61320_0.fw 04.26 NEW 61321_0.fw 04.26 NEW 61322_0.fw 04.26 NEW 61333_0.fw 04.26 NEW 61334_0.fw 04.26 NEW 61335_0.fw 04.26 NEW 61336_0.fw 04.26 NEW 61337_0.fw 04.26 NEW 61159_0.fp (SDLT) 00.04 60620_0.fp (SDL4T) 01.04 60620i0.fp (SDL4TExt.) 01.04 Change(s) 61320_0.fw, 61321_0.fw, 61322_0.fw, 61333_0.fw, 61334_0.fw, 61335_0.fw, 61336_0.fw, 61337_0.fw (MTCX Firmware): - Optimized internal power supply. - Optimized SDL link timing. - Optimized PowerOff/On/Standby handling for Hypervisor systems. - Support of alternative/new temperature sensors. ATTENTION! Possible upgrade problems and version dependency, see above. |
|||||
Версия | Язык | Операционная система | Дата | Размер | Тип | Загрузка |
1.12 | * | 15.12.2022 | 6 MB | ZIP | UPG_xPC3100_MTCX_V0112_EFI.zip | |
Описание |
xPC3100 Firmware Upgrade (MTCX, SDLT, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. 3. A Extended upgrade for the SDL4T Firmware is only necessary if an SDL4T firmware less than V01.00 is installed. 4. Starting with SDL4T Firmware V01.00, a downgrade to a version smaller then V01.00 is not possible. 5. Starting with SDL4T Firmware V01.00, a Automation Panel Firmware update for the SDL4R Firmware at least from V06.14 and HDBT Firmware at least from V01.00 is necessary. ---------------------------------------------------------------- Version 01.12 / 11/07/2022 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.12 NEW README.txt 01.12 NEW STARTUP.nsh 01.12 NEW MTCXxPC3100.nsh 01.00 SDLTxPC3100.nsh 01.09 MTCXSVC.efi 19.52 BRFSETUPD.efi 19.50 61320_0.fw 04.25 61321_0.fw 04.25 61322_0.fw 04.25 61333_0.fw 04.25 61334_0.fw 04.25 61335_0.fw 04.25 61336_0.fw 04.25 61337_0.fw 04.25 61159_0.fp (SDLT) 00.04 60620_0.fp (SDL4T) 01.04 NEW 60620i0.fp (SDL4TExt.) 01.04 NEW Change(s) 60620_0.fp (FPGA FW f. 5ACCLI02.SD40-000): - Updated HDBASET2 FW: A RFID reader was not recognized sporadically during a PowerOn using ARemb. After a warm start this behaviour could not be observed in ARemb. Also under GPOS operating systems, such as Windows 10 this behaviour could not be observed. 60620i0.fp (Extended FPGA FW f. 5ACCLI02.SD40-000): - Updated HDBASET2 FW: A RFID reader was not recognized sporadically during a PowerOn using ARemb. After a warm start this behaviour could not be observed in ARemb. Also under GPOS operating systems, such as Windows 10 this behaviour could not be observed. INFORMATION: This upgrade is only necessary if an SDL4T firmware less than V01.00 is installed. ATTENTION: Do not reset or switch off the device during the upgrade process! ATTENTION! Possible upgrade problems and version dependency, see above. |
|||||
Версия | Язык | Операционная система | Дата | Размер | Тип | Загрузка |
1.11 | * | 15.09.2022 | 6 MB | ZIP | UPG_xPC3100_MTCX_V0111_EFI.zip | |
Описание |
xPC3100 Firmware Upgrade (MTCX, SDLT, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. 3. A Extended upgrade for the SDL4T Firmware is only necessary if an SDL4T firmware less than V01.00 is installed. 4. Starting with SDL4T Firmware V01.00, a downgrade to a version smaller then V01.00 is not possible. 5. Starting with SDL4T Firmware V01.00, a Automation Panel Firmware update for the SDL4R Firmware at least from V06.14 and HDBT Firmware at least from V01.00 is necessary. ---------------------------------------------------------------- Version 01.11 / 08/18/2022 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.11 NEW README.txt 01.11 NEW STARTUP.nsh 01.11 NEW MTCXxPC3100.nsh 01.00 SDLTxPC3100.nsh 01.09 MTCXSVC.efi 19.52 NEW BRFSETUPD.efi 19.50 NEW 61320_0.fw 04.25 NEW 61321_0.fw 04.25 NEW 61322_0.fw 04.25 NEW 61333_0.fw 04.25 NEW 61334_0.fw 04.25 NEW 61335_0.fw 04.25 NEW 61336_0.fw 04.25 NEW 61337_0.fw 04.25 NEW 61159_0.fp (SDLT) 00.04 60620_0.fp (SDL4T) 01.02 60620i0.fp (SDL4TExt.) 01.02 Change(s) 61320_0.fw, 61321_0.fw, 61322_0.fw, 61333_0.fw, 61334_0.fw, 61335_0.fw, 61336_0.fw, 61337_0.fw (MTCX Firmware): - Optimized internal power supply. MTCXSVC: - Minor optimizations and bug fixes. ATTENTION! Possible upgrade problems and version dependency, see above. |
|||||
Версия | Язык | Операционная система | Дата | Размер | Тип | Загрузка |
1.10 | * | 17.05.2021 | 6 MB | ZIP | UPG_xPC3100_MTCX_V0110_EFI.zip | |
Описание |
xPC3100 Firmware Upgrade (MTCX, SDLT, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. 3. A Extended upgrade for the SDL4T Firmware is only necessary if an SDL4T firmware less than V01.00 is installed. 4. Starting with SDL4T Firmware V01.00, a downgrade to a version smaller then V01.00 is not possible. 5. Starting with SDL4T Firmware V01.00, a Automation Panel Firmware update for the SDL4R Firmware at least from V06.14 and HDBT Firmware at least from V01.00 is necessary. ---------------------------------------------------------------- Version 01.10 / 02/08/2021 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.10 NEW README.txt 01.10 NEW STARTUP.nsh 01.00 MTCXxPC3100.nsh 01.00 SDLTxPC3100.nsh 01.09 MTCXSVC.efi 19.40 61320_0.fw 04.24 61321_0.fw 04.24 61322_0.fw 04.24 61333_0.fw 04.24 61334_0.fw 04.24 61335_0.fw 04.24 61336_0.fw 04.24 61337_0.fw 04.24 61159_0.fp (SDLT) 00.04 60620_0.fp (SDL4T) 01.02 NEW 60620i0.fp (SDL4TExt.) 01.02 NEW Change(s) 60620_0.fp (FPGA FW f. 5ACCLI02.SD40-000): - Updated HDBASET2 FW: USB communication in combination with USB 3.0 devices optimized. 60620i0.fp (Extended FPGA FW f. 5ACCLI02.SD40-000): - Updated HDBASET2 FW: USB communication in combination with USB 3.0 devices optimized. INFORMATION: This upgrade is only necessary if an SDL4T firmware less than V01.00 is installed. ATTENTION: Do not reset or switch off the device during the upgrade process! ATTENTION! Possible upgrade problems and version dependency, see above. |
|||||
Версия | Язык | Операционная система | Дата | Размер | Тип | Загрузка |
1.09 | * | 17.09.2020 | 6 MB | ZIP | UPG_xPC3100_MTCX_V0109_EFI.zip | |
Описание |
xPC3100 Firmware Upgrade (MTCX, SDLT, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. 3. Starting with SDL4T Firmware V01.00, a Automation Panel Firmware update for the SDL4R Firmware at least from V06.14 and HDBT Firmware at least from V01.00 is necessary. ---------------------------------------------------------------- Version 01.09 / 07/16/2020 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.09 NEW README.txt 01.09 NEW STARTUP.nsh 01.00 MTCXxPC3100.nsh 01.00 SDLTxPC3100.nsh 01.09 NEW MTCXSVC.efi 19.40 NEW 61320_0.fw 04.24 61321_0.fw 04.24 61322_0.fw 04.24 61333_0.fw 04.24 61334_0.fw 04.24 61335_0.fw 04.24 61336_0.fw 04.24 61337_0.fw 04.24 61159_0.fp (SDLT) 00.04 60620_0.fp (SDL4T) 01.00 NEW 60620i0.fp (SDL4TExt.) 01.00 NEW Change(s) 60620_0.fp (FPGA FW f. 5ACCLI02.SD40-000): - Updated HDBASET2 FW: Necessary for the extensions of the B&R Hypervisor (USB on the Automation Panel) from AR A4.81. 60620i0.fp (Extended FPGA FW f. 5ACCLI02.SD40-000): - Updated HDBASET2 FW: Necessary for the extensions of the B&R Hypervisor (USB on the Automation Panel) from AR A4.81. INFORMATION: This upgrade is only necessary if an SDL4T firmware less than V01.00 is installed. ATTENTION: Do not reset or switch off the device during the upgrade process! MTCXSVC: - Support for SDL4T extended update (LINKIFILE). - Support for MPC3100 family. ATTENTION! Possible upgrade problems and version dependency, see above. |
|||||
Версия | Язык | Операционная система | Дата | Размер | Тип | Загрузка |
1.08 | * | 03.08.2020 | 4 MB | ZIP | UPG_xPC3100_MTCX_V0108_EFI.zip | |
Описание |
xPC3100 Firmware Upgrade (MTCX, SDLT, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. ---------------------------------------------------------------- Version 01.08 / 06/04/2020 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.08 NEW README.txt 01.08 NEW STARTUP.nsh 01.00 MTCXxPC3100.nsh 01.00 SDLTxPC3100.nsh 01.00 MTCXSVC.efi 17.90 61320_0.fw 04.24 NEW 61321_0.fw 04.24 NEW 61322_0.fw 04.24 NEW 61333_0.fw 04.24 NEW 61334_0.fw 04.24 NEW 61335_0.fw 04.24 NEW 61336_0.fw 04.24 NEW 61337_0.fw 04.24 NEW 61159_0.fp (SDLT) 00.04 NEW 60620_0.fp (SDL4T) 00.06 Change(s) 61320_0.fw, 61321_0.fw, 61322_0.fw, 61333_0.fw, 61334_0.fw, 61335_0.fw, 61336_0.fw, 61337_0.fw (MTCX Firmware): - Bugfix: in very rare cases, short sporadic display flickering can occur. Until now this effect is only seen on PPC3100. APC3100 system is not affected. - Optimization of the SDL interface in combination with DVI panels. 61159_0.fp (FPGA FW f. 5ACCLI02.SDL0-000): - Optimization of the SDL interface in combination with DVI panels. ATTENTION! Possible upgrade problems and version dependency, see above. |
|||||
Версия | Язык | Операционная система | Дата | Размер | Тип | Загрузка |
1.07 | * | 20.04.2020 | 4 MB | ZIP | UPG_xPC3100_MTCX_V0107_EFI.zip | |
Описание |
xPC3100 Firmware Upgrade (MTCX, SDLT, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. ---------------------------------------------------------------- Version 01.07 / 01/27/2020 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.07 NEW README.txt 01.07 NEW STARTUP.nsh 01.00 MTCXxPC3100.nsh 01.00 SDLTxPC3100.nsh 01.00 MTCXSVC.efi 17.90 NEW 61320_0.fw 04.22 NEW 61321_0.fw 04.22 NEW 61322_0.fw 04.22 NEW 61333_0.fw 04.22 NEW 61334_0.fw 04.22 NEW 61335_0.fw 04.22 NEW 61336_0.fw 04.22 NEW 61337_0.fw 04.22 NEW 61159_0.fp (SDLT) 00.02 60620_0.fp (SDL4T) 00.06 Change(s) 61320_0.fw, 61321_0.fw, 61322_0.fw, 61333_0.fw, 61334_0.fw, 61335_0.fw, 61336_0.fw, 61337_0.fw (MTCX Firmware): - Bugfix: Sporadically the CPU temperature showed invalid values. - Support for IF option 5ACCIF04.FPLK-000 implemented. MTCXSVC: - Support for MPC3100 family. ATTENTION! Possible upgrade problems and version dependency, see above. |
|||||
Версия | Язык | Операционная система | Дата | Размер | Тип | Загрузка |
1.06 | * | 26.04.2019 | 4 MB | ZIP | UPG_xPC3100_MTCX_V0106_EFI.zip | |
Описание |
xPC3100 Firmware Upgrade (MTCX, SDLT, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. ---------------------------------------------------------------- Version 01.06 / 03/14/2019 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.06 NEW README.txt 01.06 NEW STARTUP.nsh 01.00 MTCXxPC3100.nsh 01.00 SDLTxPC3100.nsh 01.00 MTCXSVC.efi 17.43 61320_0.fw 04.21 NEW 61321_0.fw 04.21 NEW 61322_0.fw 04.21 NEW 61333_0.fw 04.21 NEW 61334_0.fw 04.21 NEW 61335_0.fw 04.21 NEW 61336_0.fw 04.21 NEW 61337_0.fw 04.21 NEW 61159_0.fp (SDLT) 00.02 60620_0.fp (SDL4T) 00.06 Change(s) 61320_0.fw, 61321_0.fw, 61322_0.fw, 61333_0.fw, 61334_0.fw, 61335_0.fw, 61336_0.fw, 61337_0.fw (MTCX Firmware): - Optimized internal keyboard syncronization. - Optimized internal power supply syncronization. - Optimized MTCX IRQ support. - Optimized NMI syncronization. - Support for IF option 5ACCIF02.ISS0-000 implemented. ATTENTION! Possible upgrade problems and version dependency, see above. Possible upgrade problems and version dependency, see above. |
|||||
Версия | Язык | Операционная система | Дата | Размер | Тип | Загрузка |
1.05 | * | 20.11.2018 | 4 MB | ZIP | UPG_xPC3100_MTCX_V0105_EFI.zip | |
Описание |
xPC3100 Firmware Upgrade (MTCX, SDLT, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. ---------------------------------------------------------------- Version 01.05 / 10/05/2018 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.05 NEW README.txt 01.05 NEW STARTUP.nsh 01.00 MTCXxPC3100.nsh 01.00 SDLTxPC3100.nsh 01.00 MTCXSVC.efi 17.43 61320_0.fw 04.20 NEW 61321_0.fw 04.20 NEW 61322_0.fw 04.20 NEW 61333_0.fw 04.20 NEW 61334_0.fw 04.20 NEW 61335_0.fw 04.20 NEW 61336_0.fw 04.20 NEW 61337_0.fw 04.20 NEW 61159_0.fp (SDLT) 00.02 60620_0.fp (SDL4T) 00.06 Change(s) 61320_0.fw, 61321_0.fw, 61322_0.fw, 61333_0.fw, 61334_0.fw, 61335_0.fw, 61336_0.fw, 61337_0.fw (MTCX Firmware): - Bugfix: serial COMPort (FIFO). ATTENTION! Possible upgrade problems and version dependency, see above. |
|||||
Версия | Язык | Операционная система | Дата | Размер | Тип | Загрузка |
1.04 | * | 31.10.2018 | 4 MB | ZIP | UPG_xPC3100_MTCX_V0104_EFI.zip | |
Описание |
xPC3100 Firmware Upgrade (MTCX, SDLT, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. ---------------------------------------------------------------- Version 01.04 / 07/12/2018 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.04 NEW README.txt 01.04 NEW STARTUP.nsh 01.00 MTCXxPC3100.nsh 01.00 SDLTxPC3100.nsh 01.00 MTCXSVC.efi 17.43 NEW 61320_0.fw 04.19 NEW 61321_0.fw 04.19 NEW 61322_0.fw 04.19 NEW 61333_0.fw 04.19 NEW 61334_0.fw 04.19 NEW 61335_0.fw 04.19 NEW 61336_0.fw 04.19 NEW 61337_0.fw 04.19 NEW 61159_0.fp (SDLT) 00.02 60620_0.fp (SDL4T) 00.06 Change(s) 61320_0.fw, 61321_0.fw, 61322_0.fw, 61333_0.fw, 61334_0.fw, 61335_0.fw, 61336_0.fw, 61337_0.fw (MTCX Firmware): - Support for IF option 5AC901.I232-00 implemented. - Support for USB standby PowerOn switch implemented. - MTCX communication interface IRQ support implemented. MTCXSVC: - Bugfix: HV option in BIOSSET mode. ATTENTION! Possible upgrade problems and version dependency, see above. |
|||||
Версия | Язык | Операционная система | Дата | Размер | Тип | Загрузка |
1.03 | * | 29.06.2018 | 4 MB | ZIP | UPG_xPC3100_MTCX_V0103_EFI.zip | |
Описание |
xPC3100 Firmware Upgrade (MTCX, SDLT, SDL4T) ---------------------------------------------------------------- ATTENTION! Possible upgrade problems and version dependency ---------------------------------------------------------------- 1. Do not reset or switch off the device during the upgrade process !!! 2. If a UPS is connected to the system, the battery unit must be disconnected or the Power button must be pressed (to set the system in standby mode) after the upgrade is done, but before the required Power Off/On is done. Otherwise the firmware upgrade is not complete, because the UPS will provide the system with power. ---------------------------------------------------------------- Version 01.03 / 05/16/2018 / MIK !MANDATORY UPDATE! ---------------------------------------------------------------- Content LIESMICH.txt 01.03 NEW README.txt 01.03 NEW STARTUP.nsh 01.00 MTCXxPC3100.nsh 01.00 SDLTxPC3100.nsh 01.00 MTCXSVC.efi 17.42 NEW 61320_0.fw 04.18 NEW 61321_0.fw 04.18 NEW 61322_0.fw 04.18 NEW 61333_0.fw 04.18 NEW 61334_0.fw 04.18 NEW 61335_0.fw 04.18 NEW 61336_0.fw 04.18 NEW 61337_0.fw 04.18 NEW 61159_0.fp (SDLT) 00.02 60620_0.fp (SDL4T) 00.06 NEW Change(s) 61320_0.fw, 61321_0.fw, 61322_0.fw, 61333_0.fw, 61334_0.fw, 61335_0.fw, 61336_0.fw, 61337_0.fw (MTCX Firmware): - Enhancements for B&R Hypervisor. - Bugfix - Customer Panel Interface A. Inaccurate and jumping touch service. Problem only occurs in combination with a PPC3100 and a resistive single touch panel and MTCX V04.16. 60620_0.fp (FPGA FW f. 5ACCLI02.SD40-000): - Updated HDBASET2 FW. MTCXSVC: - Support for xPC2200 family. - Support for SDL4 converter. ATTENTION! Possible upgrade problems and version dependency, see above. |