General information
B&R ID code 0x2F54
System requirements
Automation Studio 4.6.1.x or later
Cooling and mounting type Wall mounting
Slots for plug-in modules 2
Certifications
CE Yes
UKCA Yes
Functional safety Yes
UL cULus E225616
Power conversion equipment
KC Yes
DC bus connection
Voltage
Nominal 750 VDC
Continuous power consumption 5.6 kW
Power dissipation depending on switching frequency
Switching frequency 5 kHz [0.6 * IM² + 1.3 * IM + 60] W
Switching frequency 10 kHz [0.97 * IM² + 0.5 * IM + 110] W
Switching frequency 20 kHz [1.7 * IM² - 0.7 * IM + 225] W
DC bus capacitance 165 µF
Variant ACOPOSmulti backplane
24 VDC power supply
Input voltage 25 VDC ±1.6%
Input capacitance 23.5 µF
Max. power consumption 12 W + PSLOT1 + PSLOT2 + P24 V Out + PHoldingBrake
Variant ACOPOSmulti backplane
24 VDC output
Quantity 2
Output voltage
DC bus voltage (UDC): 260 to 315 VDC 25 VDC * (UDC/315)
DC bus voltage (UDC): 315 to 800 VDC 24 VDC ±6%
Fuse protection 250 mA (slow-blow) electronic, automatic reset
Motor connection
Quantity 1
Continuous power per motor connection 5.5 kW
Continuous current per motor connection 7.6 Aeff
Reduction of continuous current depending on switching frequency
Switching frequency 5 kHz No reduction
Switching frequency 10 kHz 0.2 A/K (starting at 49°C)
Switching frequency 20 kHz 0.13 A/K (starting at 4°C)
Reduction of continuous current depending on installation elevation
Starting at 500 m above sea level 0.76 Aeff per 1000 m
Peak current 18.9 Aeff
Nominal switching frequency 5 kHz
Possible switching frequencies 5 / 10 / 20 kHz
Insulation stress of the connected motor per IEC TS 60034-25:2004 Limit value curve A
Protective measures
Overload protection Yes
Short-circuit and ground fault protection Yes
Max. output frequency 598 Hz
Variant
U, V, W, PE Connector
Shield connection Yes
Terminal connection cross section
Flexible and fine-stranded wires
With wire end sleeve 0.25 to 6 mm²
Approbation data
UL/C-UL-US 30 to 10 AWG
CSA 28 to 10 AWG
Terminal cable cross section dimension of shield connection 12 to 22 mm
Max. motor line length depending on switching frequency
Switching frequency 5 kHz 25 m
Switching frequency 10 kHz 25 m
Switching frequency 20 kHz 10 m
Motor holding brake connection
Quantity 1
Output voltage 24 VDC +5.8% / -0%
Continuous current per connection 1.1 A
Max. internal resistance 0.5 Ω
Extinction potential Approx. 30 V
Max. extinction energy per switching operation 1.5 Ws
Max. switching frequency 0.5 Hz
Protective measures
Overload and short-circuit protection Yes
Open-circuit monitoring Yes
Undervoltage monitoring Yes
Response threshold for open-circuit monitoring Approx. 0.25 A
Response threshold for undervoltage monitoring 24 VDC +0% / -4%
Enable inputs
Quantity 2
Circuit Sink
Electrical isolation
Input - Inverter module Yes
Input - Input Yes
Input voltage
Nominal 24 VDC
Maximum 30 VDC
Input current at nominal voltage Approx. 30 mA
Switching threshold
Low <5 V
High >15 V
Switching delay at nominal input voltage
Enable 1 → 0, PWM off Max. 20.5 ms
Enable 0 → 1, ready for PWM Max. 100 µs
Modulation compared to ground potential Max. ±38 V
OSSD signal connections Permitted
Max. test pulse length: 500 µs
Trigger inputs
Quantity 2
Circuit Sink
Electrical isolation
Input - Inverter module Yes
Input - Input Yes
Input voltage
Nominal 24 VDC
Maximum 30 VDC
Switching threshold
Low <5 V
High >15 V
Input current at nominal voltage Approx. 10 mA
Switching delay
Rising edge 52 µs ±0.5 µs (digitally filtered)
Falling edge 53 µs ±0.5 µs (digitally filtered)
Modulation compared to ground potential Max. ±38 V
Temperature sensor connection
Quantity 1
Resistance range 500 Ω to 5 kΩ
Support
Motion system
mapp Motion 5.24.1 and higher
ACP10/ARNC0 5.24.1 and higher
Electrical properties
Discharge capacitance 0.14 µF
Energy efficiency (IE classification)
Power dissipation relative to continuous apparent power IE2 (10,25) 2.5%
IE2 (50,25) 2.5%
IE2 (10,50) 2.7%
IE2 (50,50) 2.7%
IE2 (90,50) 2.7%
IE2 (10,100) 3.2%
IE2 (50,100) 3.2%
IE2 (90,100) 3.2%
Nominal losses in standby mode 8.5 W
Operating conditions
Permissible mounting orientations
Hanging vertically Yes
Horizontal, face up Yes
Standing horizontally No
Installation elevation above sea level
Nominal 0 to 500 m
Maximum 4000 m
Pollution degree per EN 61800-5-1 2 (non-conductive pollution)
Overvoltage category per EN 61800-5-1 III
Degree of protection per EN 60529 IP20
Ambient conditions
Temperature
Operation
Nominal 5 to 40°C
Maximum 55°C
Storage -25 to 55°C
Transport -25 to 70°C
Relative humidity
Operation 5 to 85%
Storage 5 to 95%
Transport Max. 95% at 40°C
Mechanical properties
Dimensions
Width 53 mm
Height 317 mm
Depth
Wall mounting 263 mm
Weight Approx. 2.7 kg
Module width 1
Référence produit:
8BVI0055HWS0.000-3
Description:
ACOPOSmulti3 inverter module, 7.6 A, AS, wall mounting, optimized for applications with decentralized, computationally intensive open-loop and closed-loop control requirements
Accessoires obligatoires
Terminal block sets
8BZVI0055S0.000-1A Jeu de borniers à vis pour modules ACOPOSmulti 8BVI00xxHxS0 : 1x 8TB3104.204G-11, 1x 8TB2104.203L-00, 1x 8TB2106.2010-00, 1x 8TB2108.2010-00
Accessoires optionnels
Accessory sets
8BXB000.0000-00 Kit d'accessoires ACOPOSmulti pour la mise en mémoire tampon de l'encodeur, composé de : 1x pile AA 3,6 V, 1x couvercle de protection pour le support de pile
Fan modules
8BXF001.0000-00 Module de ventilation ACOPOSmulti, ventilateur de remplacement pour les modules ACOPOSmulti (8BxP/8B0C/8BVI/8BVE/8B0K)
POWERLINK/Ethernet cables
X20CA0E61.00020 Câble de connexion POWERLINK/Ethernet, RJ45 à RJ45, 0,2 m
X20CA0E61.00025 POWERLINK/Ethernet connection cable, RJ45 to RJ45, 0.25 m
X20CA0E61.00030 POWERLINK/Ethernet connection cable, RJ45 to RJ45, 0.3 m
X20CA0E61.00035 POWERLINK/Ethernet connection cable, RJ45 to RJ45, 0.35 m
X20CA0E61.00050 Câble de connexion POWERLINK/Ethernet, RJ45 à RJ45, 0,5 m
X20CA0E61.00100 Câble de connexion POWERLINK/Ethernet, RJ45 à RJ45, 1 m
Plug-in modules
8BAC0120.000-1 Module enfichable ACOPOSmulti, Interface EnDat 2.1
8BAC0120.001-2 Module enfichable ACOPOSmulti, Interface EnDat 2.2
8BAC0121.000-1 Module d'extension ACOPOSmulti, Interface HIPERFACE
8BAC0122.000-1 Module enfichable ACOPOSmulti, interface résolveur 10 kHz
8BAC0123.000-1 Module enfichable ACOPOSmulti, codeur incrémental et interface codeur absolu SSI pour signaux RS422
8BAC0123.001-1 Module enfichable ACOPOSmulti, interface codeur incrémental pour 5 V asymétrique et 5 V différentiels
8BAC0123.002-1 Module enfichable ACOPOSmulti, interface codeur incrémental pour 24 V single-ended et 24 V différentiels
8BAC0124.000-1 Module d'extension ACOPOSmulti, Interface SinCos
8BAC0125.000-1 Module enfichable ACOPOSmulti, Interface SinCos EnDat 2.1/SSI/BiSS
8BAC0130.000-1 Module enfichable ACOPOSmulti, 2 sorties numériques, 50 mA, max. 62,5 kHz, 2 sorties numériques, 500 mA, max. 1,25 kHz, 2 entrées numériques 24 VDC
8BAC0130.001-1 Module enfichable ACOPOSmulti, 2 sorties numériques, 50 mA, max. 62,5 kHz, 4 sorties numériques, 500 mA, max 1,25 kHz
8BAC0132.000-1 Module enfichable ACOPOSmulti, 4 entrées analogiques ±10 V
8BAC0133.000-1 Module enfichable ACOPOSmulti, 3 sorties RS422 pour l'émulation de l'encodeur ABR, 1 MHz
Shield component sets
8SCS000.0000-00 Kit de composants pour bouclier ACOPOSmulti : 1x plaque de blindage 1x type 0, 1x collier de serrage, B 9 mm, D 12-22 mm
8SCS002.0000-00 Kit de composants pour bouclier ACOPOSmulti : 1x plaque de serrage, 2x pince D 4-13.5 mm, 2x vis
8SCS005.0000-00 Jeu de composants pour bouclier ACOPOSmulti : 1x couvercle de fente / plaque de blindage
8SCS009.0000-00 Kit de composants de blindage ACOPOSmulti : 1x plaque de maintien ACOPOSmulti SK8-14, 1x pince de connexion de blindage SK14
Terminal blocks
8TB2104.203L-00 Bornier à vis à 4 broches, 1 rangée, pas : 5,08 mm, étiquette 3 : T- T+ B- B+, codage L : 1010
8TB2106.2010-00 Bornier à vis à 6 broches, 1 rangée, pas : 5,08 mm, étiquette 1 : numérotée consécutivement
8TB2108.2010-00 Bornier à vis à 8 broches, 1 rangée, pas : 5,08 mm, étiquette 1 : numérotée consécutivement
8TB3104.204G-11 Bornier à vis à 4 broches, 1 rangée, pas : 7,62 mm, étiquette 4 : PE W V U, codage G : 0110

Veuillez sélectionner un pays et une langue

B&R Logo