General information
LEDs L1, L2, L3
B&R ID code 0xE53F
Certifications
CE Yes
UKCA Yes
UL cULus E115267
Industrial control equipment
HazLoc cULus HazLoc E180196
Industrial control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T4
DNV Temperature: B (0 - 55°C)
Humidity: B (up to 100%)
Vibration: A (0.7 g)
EMC: B (bridge and open deck)
LR ENV3
KR Yes
ABS Yes
BV EC31B
Temperature: 5 - 55°C
Vibration: 0.7 g
EMC: Bridge and open deck
EAC Product family certification
Controller
FRAM
Size 32 kB
Data retention 10 years
Read/Write endurance Min. 1012 times/byte
Remanent variables in power failure mode 32 kB
(for e.g. Automation Runtime, see Automation Help)
Interfaces
COM
Quantity 1
Type RS232, modem not supported, not galvanically isolated
Variant 10-pin, male
UART 16550-compatible, 16-byte FIFO buffer
Max. baud rate 115 kbit/s
POWERLINK
Quantity 1
Type Type 4
Variant RJ45, shielded
Transfer rate 100 Mbit/s
Transfer 100BASE-TX
Line length Max. 100 m between two stations (segment length)
CAN
Quantity 1
Variant 10-pin, male, not galvanically isolated
Transfer rate Max. 1 Mbit/s
Terminating resistor
Type Can be switched on and off with slide switch
Default setting Off
Electrical properties
Power consumption 1.75 W
Operating conditions
Pollution degree per EN 61131-2 Pollution degree 2
Ambient conditions
Temperature
Operation -20 to 55°C
Storage -20 to 60°C
Transport -20 to 60°C
Relative humidity
Operation 5 to 90%, non-condensing
Storage 5 to 95%, non-condensing
Transport 5 to 95%, non-condensing
Mechanical properties
Weight 25 g
Material number:
5ACCIF01.FPSC-000
Description:
  • 1x POWERLINK interface managing or controlled node
  • 1x CAN bus master interface
  • 1x RS232 interface
  • 32 kB FRAM
  • Compatible with APC2100/PPC2100 and APC2200/PPC2200

Interface option 5ACCIF01.FPSC-000 is equipped with a POWERLINK, RS232 and CAN bus master interface. In addition, 32 kB FRAM is installed.

Optional Accessories
Terminal blocks
0TB1210.3100 Connector 300 VDC - 10-pin female - Cage clamp terminal block - Protected against vibration by the screw flange
Automation Studio HW Upgrades Version (Date) Download
V4.0 HW Upgrade (5ACCIF01.FPSC-000) EXE / 643 KB
V4.1 HW Upgrade (5ACCIF01.FPSC-000) EXE / 904 KB
Certificates Version (Date) Download
DNV Type Approval Certificate - Automation PC 2100 PDF / 218 KB
Documentation Version (Date) Download
Automation PC 2100 Device number key PDF / 116 KB
Automation PC 2100 User's manual PDF / 28 MB
Automation PC 2200 User's manual PDF / 13 MB
Panel PC 2100 (AP5000) Swing arm devices user's manual PDF / 43 MB
Panel PC 2100 Built-in devices User's manual PDF / 40 MB
Panel PC 2100 Swing arm devices User´s Manual PDF / 14 MB
Panel PC 2200 (AP5000) swing arm devices user's manual PDF / 29 MB
Panel PC 2200 Panel mount devices User's manual PDF / 20 MB
E-CAD (Electro or EPLAN Templates) Version (Date) Download
APC EPLAN P8 from V2.4 EXE / 99 MB
Firmware Upgrades Version (Date) Download
APC2100 Firmware Upgrade (MTCX, SDLT, SDL3T) ZIP / 2 MB
PPC2100 Firmware Upgrade (MTCX) ZIP / 4 MB

Please choose country and language

B&R Logo