General information
B&R ID code | 0xA7A9 |
Status LED | Yes |
Electrical isolation | |
Mains input - Power output | Yes |
Mains input - 24 VDC | Yes |
Power output - 24 VDC | No |
X2X Link - Mains input | Yes |
X2X Link - Power output | Yes |
X2X Link - 24 VDC | Yes |
Connection type | Maximum 25 m line length to the power supply module |
Certifications | |
CE | Yes |
UKCA | Yes |
UL |
cULus E225616 Power conversion equipment |
EAC | Yes |
KC | Yes |
Mains input
Input voltage range | 3x 380 to 480 VAC ±10% |
Input current at full load |
3x 2.2 A at 400 VAC 3x 1.8 A at 480 VAC |
Frequency range of mains voltage | 50 to 60 Hz ±5% |
Phase failure detector | Yes |
Power failure bypass | 10 ms (at full load) |
Power factor (cos φ) |
0.72 @ 400 V 1 kW 0.69 @ 480 V 1 kW |
Leakage current to PE | <3.5 mA |
Protective circuit | Transient surge protection with varistor |
Fuse protection | |
Internal | Each phase internally fused (5 A) |
External | External fuse required for line protection |
Power output
24 VDC voltage output
Voltage range | 24 VDC ±10% |
Output current | Max. 2 A continuous current |
Output protection | Short-circuit, overload and no-load proof |
Parallel connection | No |
Chopper output
Response threshold for chopper activation | 29 to 95 VDC (adjustable) |
Overtemperature protection (chopper-internal) | Yes |
Output current / Output power | |
Continuous current / Continuous power | 30 A |
Maximum current / Maximum power | 40 A |
Interfaces
User interface | |
Variant | 10-pin terminal block |
Type | X2X Link |
Min. X2X Link cycle time | 250 µs |
Efficiency, reliability
Efficiency | >92% |
Power dissipation | |
Rated load | 90 W |
No-load operation | 30 W |
Operating conditions
Mounting orientation | |
Vertical | Yes |
Ventilation/Cooling | Internally controlled fan |
Degree of protection per EN 60529 | IP20 |
Ambient conditions
Temperature | |
Operation | 0 to 50°C |
Storage | -25 to 85°C |
Transport | -25 to 85°C |
Relative humidity | |
Operation | 5 to 95%, non-condensing |
Storage | 5 to 95%, non-condensing |
Transport | 5 to 95%, non-condensing |
Mechanical properties
Material | Robust metal housing |
Dimensions | |
Width | 67.5 mm |
Height | 257 mm |
Depth | 219 mm |
Weight | 3.75 kg |
Material number:
80PS080X3.10-01Description:
- Input: 3x 380 to 480 VAC ±10%
- Output voltage adjustable via X2X Link
- Status information readable via X2X Link
- Chopper output for connecting an external braking resistor
- 3-phase wide range input
- Closed metal housing
Mandatory Accessories
Terminal block sets
80XPS080X3.10-01A | Screw clamp terminal block set for 80PS080X3.10-01: 1x 0TB3104-7021, 1x 0TB3104-7022, 1x 0TB3102-7010, 1x 0TB1110.8010, 1x 0TB103.3 |
Optional Accessories
Braking resistor
80XBR0025.010-11 | Braking resistor for power supply module 80PS080X3.10-01 2.5 Ω 100 W |
Automation Studio HW Upgrades | Version (Date) | Download |
---|---|---|
V2.6 HW Upgrade (80PS080X3.10-01) | EXE / 3 MB | |
V3.0 HW Upgrade (80PS080X3.10-01) | EXE / 1 MB | |
V4.0 HW Upgrade (80PS080X3.10-01) | EXE / 2 MB |
Certificates | Version (Date) | Download |
---|---|---|
E225616 UL Certificate of Compliance ACOPOSmicro | PDF / 83 KB | |
EU Declaration ACOPOSmicro | PDF / 201 KB | |
UK Declaration ACOPOSmicro | PDF / 109 KB |
Documentation | Version (Date) | Download |
---|---|---|
ACOPOSmicro User's Manual | PDF / 66 MB | |
Data sheet 80PS080X3.10-01 | PDF / 10 MB |
E-CAD (Electro or EPLAN Templates) | Version (Date) | Download |
---|---|---|
Power supplies EPLAN P8 | EXE / 14 MB |
M-CAD (Mechan. Templates) | Version (Date) | Download |
---|---|---|
3D file STEP 80PS080X3.10-01 | ZIP / 373 KB |