General information
Support
Dynamic node allocation (DNA) Yes
Certifications
CE Yes
UKCA Yes
CRA (Cyber Resilience Act) In preparation
UL cULus E225616
Power conversion equipment
KC Yes
Note Integrated passive motor short circuit brake
B&R ID code 0xA987
Cooling and mounting type Cold plate or pass-through mounting
Mains connection
Max. chargeable DC bus capacitance depending on mains voltage
400 VAC 14.4 mF
480 VAC 10 mF
Variant
L1, L2, L3, PE Connector
PE M5 threaded bolt
Shield connection Yes
Terminal connection cross section
Flexible and fine-stranded wires
With wire end sleeve 0.5 to 16 mm²
Approbation data
UL/C-UL-US 20 to 6 AWG
CSA 20 to 6 AWG
Network configurations TT, TN-S, TN-C-S
Mains input voltage 3x 380 to 3x 500 VAC ±10%
Frequency 50 / 60 Hz ±4%
Installed load Max. 15.6 kVA
Power dissipation with continuous power Approx. 130 W
Inrush current at 400 VAC 10 A
Switch-on interval >120 s
Integrated line filter per EN 61800-3, category C3 No
Integrated regeneration choke No
Regenerative No
Power factor correction (PFC) No
Line fuse Max. 66 A (gG fuses per IEC 60269-1 or Class CC, J, T)
Max. 55 A (circuit breaker per EN 60947-2 or UL 489)
Terminal cable cross section dimension of shield connection 23 to 35 mm
DC bus connection
Voltage
Nominal 537 to 707 VDC
Reduction of continuous power depending on mains input voltage
Mains input voltage <3x 400 VAC 20 W/V * (400 V - Mains input voltage)
Reduction of continuous power depending on installation elevation
Starting at 500 m above sea level 0.8 kW per 1000 m
Protective measures
Overload protection Yes
Short-circuit and ground fault protection No
Continuous power 8 kW
Reduction of continuous power depending on cooling method In preparation
Peak power output (supply) 24 kW
Power dissipation with continuous power In preparation
DC bus capacitance 660 µF
Variant ACOPOSmulti backplane
24 VDC power supply
Input voltage 25 VDC ±1.6%
Input capacitance 23.5 µF
Max. power consumption 12 W
Variant ACOPOSmulti backplane
Motor holding brake connection
Terminal connection cross section
Flexible and fine-stranded wires
With wire end sleeve 0.5 to 6 mm²
Approbation data
UL/C-UL-US 20 to 6 AWG
CSA 20 to 6 AWG
Braking resistor
Variant
RB+, RB-, PE Connector
Shield connection Yes
Protective measures
Overload protection Yes
Short-circuit and ground fault protection Yes (with RB+ by externally replaceable melting fuse)
Peak power output 40 kW (max. 1 s)
Continuous power 3 kW
Min. braking resistance 12 Ω
Rated current of built-in fuse 30 A (fast-acting)
Terminal cable cross section dimension of shield connection 23 to 35 mm
Electrical properties
Energy efficiency (IE classification)
Power dissipation relative to continuous apparent power IE2 (10;25) 0.2%
IE2 (50;25) 0.3%
IE2 (10;50) 0.2%
IE2 (50;50) 0.3%
IE2 (90;50) 0.6%
IE2 (10;100) 0.3%
IE2 (50;100) 0.6%
IE2 (90;100) 1.3%
Nominal losses in standby mode 6 W
Discharge capacitance 0.9 µF
Operating conditions
Permissible mounting orientations
Hanging vertically Yes
Horizontal, face up Yes
Standing horizontally No
Installation elevation above sea level
Nominal 0 to 500 m
Maximum 4000 m
Pollution degree per EN 61800-5-1 2 (non-conductive pollution)
Overvoltage category per EN 61800-5-1 III
Degree of protection per EN 60529 IP20
Ambient conditions
Temperature
Operation
Nominal 5 to 40°C
Maximum 55°C
Storage -25 to 55°C
Transport -25 to 70°C
Relative humidity
Operation 5 to 85%
Storage 5 to 95%
Transport Max. 95% at 40°C
Mechanical properties
Dimensions
Depth
Cold plate 212 mm
Pass-through mounting 209 mm
Width 106.5 mm
Height 317 mm
Weight Approx. 4.7 kg
Module width 2
Material number:
8B0P0220HC00.001-1
Description:
  • Wide input voltage range
  • Integrated connection for external braking resistor
  • Passive motor short circuit brake
ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
Mandatory Accessories
Terminal block sets
8BZ0P044000.000-1A ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
Optional Accessories
Braking resistors
8B0W0045H000.001-1 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
8B0W0079H000.000-1 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
8B0W0079H000.001-1 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
Fan modules
8BXF001.0000-00 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
Fuse sets
8BXS003.0000-00 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
POWERLINK/Ethernet cables
X20CA0E61.00020 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
X20CA0E61.00025 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
X20CA0E61.00030 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
X20CA0E61.00035 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
X20CA0E61.00050 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
X20CA0E61.00100 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
Shield component sets
8SCS000.0000-00 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
8SCS002.0000-00 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
8SCS009.0000-00 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
8SCS010.0000-00 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
Terminal blocks
8TB2106.2010-00 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
8TB4103.202A-00 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
8TB4104.202L-10 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
Undefined
8B0W0045H000.000-1 ACOPOSmulti power supply module passive, 22 A, AS, cold plate or pass-through mounting, passive motor short circuit brake
Automation Studio HW Upgrades Version (Date) Download
V3.0 HW Upgrade (8B0PXXXXXXXX.XXX-X) EXE / 399 KB
V4.0 HW Upgrade (8B0P0220HC00.001-1) EXE / 306 KB
V4.0 HW Upgrade (8B0Pxxxxxxxx.xxx-1) EXE / 676 KB
V4.0 HW Upgrade (8B0Pxxxxxxxx.xxx-x) EXE / 517 KB
V6.0 HW Upgrade (8B0P0220HC00.001-1) EXE / 399 KB
V6.0 HW Upgrade (8B0Pxxxxxxxx.xxx-1) EXE / 399 KB
Certificates Version (Date) Download
ACOPOSmulti KC certificates ZIP / 3 MB
E225616 UL Certificate of Compliance ACOPOSmulti (UL 508C) PDF / 282 KB
E225616 UL Certificate of Compliance ACOPOSmulti (UL 61800-5-1) PDF / 183 KB
EU Declaration Servos ACOPOSmulti PDF / 219 KB
UK Declaration Servos ACOPOSmulti PDF / 109 KB
Documentation Version (Date) Download
ACOPOSmulti User´s Manual PDF / 308 MB
Datasheet 8B0P0220HC00.001-1 PDF / 4 MB
E-CAD (Electro or EPLAN Templates) Version (Date) Download
ACOPOSmulti EPLAN P8 from V2.4 EXE / 81 MB
M-CAD (Mechan. Templates) Version (Date) Download
3D file STEP 8B0P0xx0HC00.00x-1 ZIP / 139 KB

Please choose country and language

B&R Logo