Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.5.2.0 | * | 29/04/2024 | 6 MB | EXE | AS6_HW_X90CP174.24-00.exe | |
Description |
V6.0 HW Upgrade (X90CP174.24-00) Revision information X90CP174.24-00 Version 1.5.2.0: ID: 786545 Chapter "Configuration" added to documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60292_1.fp(32), 2\60292_1.fp(54) Version 1.5.1.0: ID: 785760 Enhancementsfor AS6/AR6 - configurable IpForwarding. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 785775 New datasheet version 2.50 Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\60292_1.fp(32), 2\60292_1.fp(54) Version 1.5.0.0: ID: 779245 Operating mode iCN on POWERLINK: spurious connection problem to the managerafter power fail corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 780590 Error in AB counter mode fixed. When a channel was configured as "Digital input source", the "Counter" Register was not reset to zero after reboot. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\60292_1.fp(32), 2\60292_1.fp(54) Version 1.4.6.0: ID: 762075 / Support ID: 400392864 X2X bus output cycle trigger error correction The X2X bus output cycle trigger was not started although it was configured. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.4.5.0: ID: 743060 / Support ID: 400368170 Broadcast channels missing in PLK interface Due to the change to Powerlink type 6, the broadcastchannels have to be included. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.4.4.0: ID: 729145 Support for POWERLINK type 6 The module now supports POWERLINK type 6 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 729200 / Support ID: 400352024 Support for 6 A current on parallel channels When two 6 A channels are used in parallel mode, a total current of 12 A isnow possible. Attention: When using 4 A and 6 A channels in parallel, each channel can only supply 4 A. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.4.3.0: ID: 714650 Module documentation revised Data sheet V2.30 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.4.0.0: ID: 684690 Module documentation revised Data sheet V2.21 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 685900 Module documentation revised Data sheet V2.21 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 703150 Enables second CPU core for I/O processing The I/O input processing can be assigned to the the second CPU core. This frees CPU processing power to be used by the application. Channeldescription changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.3.1.0: ID: 694790 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 694895 Support for automatic DNA configuration from AS 4.9.1 Networktype Powerlink added. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.3.0.0: ID: 693005 Enable TFTP server To enable a firmware update for mobile panels, theTFTP Server must be activated. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.2.4.0: ID: 673585 Description of "Total Current" changed to 0-45 A Channel descriptionchanged: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.2.3.0: ID: 668105 AS4.8 Enhancement CPU configuration: Loss of remanent data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.2.2.0: ID: 656135 Improved I/O Minimal requirements AS version 4.7.1 and AR 4.71 New functions: Analogue Channels Resistor measurement 0-50 kOhm Temperature measurement PT1000 Current measurement: 4-20 mA Digital Output Channels: Adjustable maximum current 0-4 A PWM Channels: H-Bridge mode Dithering Adjustable maximum current 0-4 A / 0-6A up to 4 kHz in PWM mode, up to 8 kHz im H-brigde mode Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.0.3.0: ID: 589275 / Support ID: 400249041 Help improved fordescription or register StatusSensorSupply Channel description changed: No Configuration description changed: No Firmware changed: No ID: 617585 / Support ID: 400261388 Corrupted CAN messages on IF9 (CAN3) With heavy load on the processor interface a "race condition" may existon the CAN control for IF9 (CAN3). As a result, the register access and the data access may interfere. For solving this "race condition" a locking mechanism hasbeen added, that allows data access to the CAN component only after the configuration via register accesses have been finished. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\60292_1.fp(24) Version 1.0.2.0: ID: 573915 Support X90CP174.24-00 Important Remark: To use the help, a minimum version 4.3.5.24 of the Automation Studio Main Help is required. Otherwise the upgrade is installed, but the help pages are empty. In case you installed the upgrade in the wrong order, you must first uninstall the Main Help using the Windows Control Panel, install the Main Help again and then apply the Module Upgrade. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60292_1.fp(23) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.5.0.0 | * | 01/02/2024 | 6 MB | EXE | AS6_HW_X90CP174.24-00.exe | |
Description |
V6.0 HW Upgrade (X90CP174.24-00) Revision information X90CP174.24-00 Version 1.5.0.0: ID: 779245 Operating mode iCN on POWERLINK: spurious connection problem to the managerafter power fail corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 780590 Error in AB counter mode fixed. When a channel was configured as "Digital input source", the "Counter"Register was not reset to zero after reboot. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\60292_1.fp(32), 2\60292_1.fp(54) Version 1.4.6.0: ID: 762075 / Support ID: 400392864 X2X bus output cycle trigger error correction The X2X bus output cycle trigger was not started although it was configured. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.4.5.0: ID: 743060 / Support ID: 400368170 Broadcast channels missing in PLK interface Due to the change toPowerlink type 6, the broadcast channels have to be included. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version1.4.4.0: ID: 729145 Support for POWERLINK type 6 The module now supports POWERLINK type 6 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 729200 / Support ID: 400352024 Support for 6 A current on parallel channels When two 6 A channels are used in parallel mode, a total current of 12 A isnow possible. Attention: When using 4 A and 6 A channels in parallel, each channel can only supply 4 A. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.4.3.0: ID: 714650 Module documentation revised Data sheet V2.30 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.4.0.0: ID: 684690 Module documentation revised Data sheet V2.21 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 685900 Module documentation revised Data sheet V2.21 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 703150 Enables second CPU core for I/O processing The I/O input processing can be assigned to the the second CPU core. This frees CPU processing power to be used by the application. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.3.1.0: ID: 694790 Supportdata point StorageWear, wear level of storage medium starting from AR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 694895 Support for automatic DNA configuration from AS 4.9.1 Networktype Powerlink added. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.3.0.0: ID: 693005 Enable TFTP server To enable a firmware update for mobile panels, the TFTP Server must be activated. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.2.4.0: ID: 673585 Description of "Total Current" changed to0-45 A Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.2.3.0: ID: 668105 AS4.8 Enhancement CPU configuration: Loss of remanent data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.2.2.0: ID: 656135 Improved I/O Minimal requirements AS version 4.7.1 and AR 4.71 New functions: Analogue Channels Resistor measurement 0-50 kOhm Temperature measurement PT1000 Current measurement: 4-20 mA Digital Output Channels: Adjustable maximum current 0-4A PWM Channels: H-Bridge mode Dithering Adjustable maximum current 0-4 A / 0-6 A up to 4 kHz in PWM mode, up to 8 kHz im H-brigde mode Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60292_1.fp(24), 2\60292_1.fp(50) Version 1.0.3.0: ID: 589275 / Support ID: 400249041 Help improved for description or register StatusSensorSupply Channel description changed: No Configuration description changed: No Firmware changed: No ID: 617585 / Support ID: 400261388 Corrupted CAN messages on IF9 (CAN3) With heavy load on the processor interface a "race condition" may exist on the CAN control for IF9 (CAN3). As a result, the register access and the data access may interfere. For solving this "race condition" a locking mechanism has been added, that allows data access to the CAN component only after the configuration via register accesses have been finished. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\60292_1.fp(24) Version 1.0.2.0: ID: 573915 Support X90CP174.24-00 Important Remark: To use the help, a minimum version 4.3.5.24 of the Automation Studio Main Help is required. Otherwise the upgrade is installed, but the help pages are empty. In case you installed the upgrade in the wrong order, you must first uninstall the Main Help using the Windows Control Panel, install the MainHelp again and then apply the Module Upgrade. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60292_1.fp(23) |