DWL@DWL10000774743
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.5.2.0 | * | 29/04/2024 | 6 MB | EXE | AS6_HW_X90CP172.48-00.exe | |
Description |
V6.0 HW Upgrade (X90CP172.48-00) Revision information X90CP172.48-00 Version 1.5.2.0: ID: 786540 Chapter "Configuration" added to documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(54) Version 1.5.1.0: ID: 785755 Enhancementsfor AS6/AR6 - configurable IpForwarding. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 785770 New datasheet version 2.10 Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(54) Version 1.5.0.0: ID: 780595 Error in AB counter mode fixed. When a channel was configured as "Digital input source", the "Counter" Register was not reset to zero after reboot. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\60333_1.fp(24), 2\60333_1.fp(54) Version 1.4.6.0: ID: 762070 / Support ID: 400392864 X2X bus output cycle trigger error correction The X2X bus outputcycle trigger was not started although it was configured. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.4.4.0: ID: 729195 / Support ID: 400352024 Support for 6 A current on parallel channels When two 6 A channels are used in parallel mode, a total current of 12 A isnow possible. Attention: When using 4 A and 6 A channels in parallel, each channel can only supply 4 A. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.4.3.0: ID: 714640 Module documentation revised Data sheet V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.4.0.0: ID: 703145 Enables second CPU core for I/O processing The I/O input processing can be assigned to the the second CPU core. This frees CPU processing power to be used by the application. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.3.1.0: ID: 694785 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 694890 Description of input channels 25-32 wrong (sink instead of source) Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.3.0.0: ID: 692919 Enable TFTP server To enable a firmware update for mobile panels, the TFTP Server must be activated. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.2.4.0: ID: 673580 Description of "Total Current" changed to 0-45 A Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.2.3.0: ID: 668100 AS4.8 Enhancement CPU configuration: Loss of remanent data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.2.2.0: ID: 656130 Improved I/O Minimal requirements ASversion 4.7.1 and AR 4.71 New functions: Analogue Channels Resistor measurement 0-50 kOhm Temperature measurement PT1000 Current measurement: 4-20 mA Digital Output Channels: Adjustable maximum current 0-4 A PWM Channels: H-Bridge mode Dithering Adjustable maximum current 0-4 A / 0-6 A up to 4 kHzin PWM mode, up to 8 kHz im H-brigde mode Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.0.3.0: ID: 589270 / Support ID: 400249041 Improve help on Sensor Supply status. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 616965 / Support ID: 400261388 Corrupted CAN messages on IF9 (CAN3) With heavy load on the processor interface a "race condition" may exist on the CAN control for IF9 (CAN3). As a result, the register access and the data access may interfere. For solving this "race condition" a locking mechanism has been added, that allows data access to the CAN component only after the configuration via register accesses have been finished. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 617580 / Support ID: 400261388 Corrupted CAN messages on IF9 (CAN3) With heavy load on the processor interface a "race condition" may exist on the CAN control for IF9 (CAN3). As a result, the register access and the data access may interfere. For solving this "race condition" a locking mechanism has been added, that allows data access to the CAN component only after the configuration via register accesses have been finished. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\60333_1.fp(24) Version 1.0.2.0: ID: 573920 Support X90CP172.48-00 Important Remark: To use the help, a minimum version 4.3.5.24 of theAutomation Studio Main Help is required. Otherwise the upgrade is installed, but thehelp pages are empty. In case you installed the upgrade in the wrong order, you must first uninstall the Main Help using the Windows Control Panel, installthe Main Help again and then apply the Module Upgrade. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60333_1.fp(23) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.5.0.0 | * | 01/02/2024 | 5 MB | EXE | AS6_HW_X90CP172.48-00.exe | |
Description |
V6.0 HW Upgrade (X90CP172.48-00) Revision information X90CP172.48-00 Version 1.5.0.0: ID: 780595 Error in AB counter mode fixed. When a channel was configured as "Digital input source", the "Counter" Register was not reset to zero after reboot. Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\60333_1.fp(24), 2\60333_1.fp(54) Version 1.4.6.0: ID: 762070 / Support ID: 400392864 X2X bus output cycle trigger error correction The X2X bus output cycle trigger was not started although it wasconfigured. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.4.4.0: ID: 729195 / Support ID: 400352024 Support for 6 A current on parallel channels When two 6 A channels are used in parallel mode, a total current of 12 A isnow possible. Attention: When using 4 A and 6 A channels in parallel, each channel can only supply 4A. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.4.3.0: ID: 714640 Module documentation revised Data sheet V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.4.0.0: ID: 703145 Enables second CPU core for I/O processing The I/O input processing can be assigned to the the second CPU core. This frees CPU processing power to be used by the application. Channel description changed: Yes Configurationdescription changed: Yes Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.3.1.0: ID: 694785 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 694890 Description of input channels 25-32 wrong (sink instead of source) Channel description changed:Yes Configuration description changed: No Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.3.0.0: ID: 692919 Enable TFTP server To enable a firmware update for mobile panels, the TFTP Server must be activated. Channel description changed:No Configuration description changed: Yes Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.2.4.0: ID: 673580 Description of "Total Current" changed to 0-45 A Channeldescription changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.2.3.0: ID: 668100 AS4.8 Enhancement CPU configuration: Loss of remanent data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.2.2.0: ID: 656130 Improved I/O Minimal requirements AS version 4.7.1 and AR 4.71 New functions: Analogue Channels Resistor measurement 0-50 kOhm Temperature measurement PT1000 Current measurement: 4-20 mA Digital Output Channels: Adjustable maximum current 0-4 A PWM Channels: H-Bridge mode Dithering Adjustable maximum current0-4 A / 0-6 A up to 4 kHz in PWM mode, up to 8 kHz im H-brigde mode Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60333_1.fp(24), 2\60333_1.fp(50) Version 1.0.3.0: ID: 589270 / Support ID: 400249041 Improve help on Sensor Supply status. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 616965 / Support ID: 400261388 Corrupted CAN messages on IF9 (CAN3) Withheavy load on the processor interface a "race condition" may exist on the CANcontrol for IF9 (CAN3). As a result, the register access and the data access may interfere. For solving this "race condition" a locking mechanism has been added, that allows data access to the CAN component only after the configuration via register accesses have been finished. Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 617580 / Support ID: 400261388 Corrupted CAN messages on IF9 (CAN3) With heavy load on the processor interface a "race condition" may exist on the CAN control for IF9 (CAN3). As a result, the register access and thedata access may interfere. For solving this "race condition" a locking mechanism hasbeen added, that allows data access to the CAN component only after the configuration via register accesses have been finished. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\60333_1.fp(24) Version 1.0.2.0: ID: 573920 Support X90CP172.48-00 Important Remark: To use the help, aminimum version 4.3.5.24 of the Automation Studio Main Help is required. Otherwise the upgrade is installed, but thehelp pages are empty. In case you installed the upgrade in the wrong order, you must first uninstall the Main Help using the Windows Control Panel, installthe Main Help again and then apply theModule Upgrade. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60333_1.fp(23) |