2.4.1.1 * 17/08/2022 2 Mo EXE AS4_HW_X20SRT842.exe
Description V4.6 HW Upgrade (X20SRT842)

Revision information X20SRT842

Version 2.4.1.1:

ID: 747215 / Support ID: 400371454
Readback value of the channels are now available.
Readback value "PhysicalStateOutputxx" of the channel is now available for all channels in SafeDESIGNER.
Channeldescription changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 10\59225_1.fw(575)

Version 2.4.1.0:

ID: 744630
Hardware error evaluation if release is constantly true.
The hardware errors are now also evaluated if Release signal is constantly true.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 744640
New data sheet V2.11
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59225_1.fw(575)

Version 2.4.0.0:

ID: 715270
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 726635
The power calculation of the modules is supported
The data for the power calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 727145
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59225_1.fw(574)

Version 2.3.0.1:

ID: 692360
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 692405
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 696580
New data sheet V2.08
For changes see chapter "Version history" in thedata sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59225_1.fw(573)

Version 2.2.0.1:

ID: 668610
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688760 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though theparametrized "safe data duration"is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689710
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689900
Increased delay of external feedback error detection
Increased delay of external feedback error detection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689945
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690005
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690090
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59225_1.fw(571)

Version 2.1.0.0:

ID: 644265
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\59225_1.fw(570)

Version 1.10.9.1:

ID: 643160
data sheetV1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59225_1.fw(330)

Version 1.10.9.0:

ID: 618280
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59225_1.fw(330)

Version 1.10.2.2:

ID: 537515 / Support ID: 400220092
Show consumed SRT cycle time
Show consumed SRT cycle time
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 541770
New default values
Default values for discrepancytime ans filter on changed
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 542350 / Support ID: 400221738
Correction of the Feedback evaluation
Correction in the evaluation of the SO-feedbacks.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 552365
User configurable Toff filter, new default value
Toff filter is now configurable to 0us. A "filter on" value of less than 1000us in combination with "Pulse Mode internal" can lead to unintended deactivation or troggling of the safe input. For existing projects this has to be verified.
Default value changed to 1000us.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 554670 / Support ID: 400228406
ChannelOk reset with OSSD-Signals near the SRT-Cycletime
OSSD-signals similar to the SRT-cycletime cause channel errors. With the change the ChannelOk remains high andfilters can be applied.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 557005 / Support ID: 400230951
Fix the output channel in combined SRT- and SC-mode
Fix the out channel if an output is set by the SRT and the SC-part of the module
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 558620
Correction of theparameter download
Correction of the parameter download to the SRT-module
Channel description changed: No
Configuration description changed:No
Firmware changed: Yes
Firmware: 1\59225_1.fw(327)

Version1.10.1.0:

ID: 530020
first official release
first officialrelease
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59225_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.4.1.0 * 16/03/2022 2 Mo EXE AS4_HW_X20SRT842.exe
Description V4.6 HW Upgrade (X20SRT842)

Revision information X20SRT842

Version 2.4.1.0:

ID: 744630
Hardware error evaluation if release is constantly true.
The hardware errors are now also evaluated if Release signal is constantly true.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 744640
New data sheet V2.11
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59372_1.fw(575)

Version 2.4.0.0:

ID: 715270
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 726635
The power calculation of the modules is supported
The data for the power calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 727145
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59372_1.fw(574)

Version 2.3.0.1:

ID: 692360
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 692405
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 696580
New data sheet V2.08
For changes see chapter "Versionhistory" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59372_1.fw(573)

Version 2.2.0.1:

ID: 668610
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688760 / Support ID: 400299371
Loss of safety connection
Loss of safety connection,even though the parametrized "safe data duration"is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689710
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689900
Increased delay of external feedback error detection
Increased delay of external feedback error detection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689945
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed:No
Firmware changed: Yes

ID: 690005
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690090
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59372_1.fw(571)

Version 2.1.0.0:

ID: 644265
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\59372_1.fw(570)

Version 1.10.9.1:

ID: 643160
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmwarechanged: No
Firmware: 1\59372_1.fw(330)

Version 1.10.9.0:

ID: 618280
logger entry 112174, 108078
Logger entry 112174, 108078could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59372_1.fw(330)

Version 1.10.2.2:

ID: 537515 /Support ID: 400220092
Show consumed SRT cycle time
Show consumed SRT cycle time
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 541770
New default values
Default values for discrepancytime ans filter on changed
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 542350 / Support ID: 400221738
Correction of the Feedback evaluation
Correction in the evaluation of the SO-feedbacks.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 552365
User configurable Toff filter, new default value
Toff filter is now configurable to 0us. A "filter on" value of less than 1000us in combination with "Pulse Mode internal" can lead to unintended deactivation or troggling of the safe input. For existing projects this has to be verified.
Default value changed to 1000us.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 554670 / Support ID: 400228406
ChannelOk reset with OSSD-Signals near the SRT-Cycletime
OSSD-signals similar to the SRT-cycletime cause channel errors. With the change the ChannelOk remains high and filters can be applied.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 557005 / Support ID: 400230951
Fix the output channel in combined SRT- and SC-mode
Fix the out channel if an output is set by the SRT and theSC-part of the module
Channel description changed: No
Configurationdescription changed: No
Firmware changed: Yes

ID: 558620
Correction of the parameter download
Correction of the parameter download to the SRT-module
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59372_1.fw(327)

Version 1.10.1.0:

ID: 530020
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59372_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.4.0.0 * 09/06/2021 2 Mo EXE AS4_HW_X20SRT842.exe
Description V4.6 HW Upgrade (X20SRT842)

Revision information X20SRT842

Version 2.4.0.0:

ID: 715270
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data"
Channel description changed: No
Configurationdescription changed: No
Firmware changed: Yes

ID: 726635
The power calculation of the modules is supported
The data for the power calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 727145
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59372_1.fw(574)

Version 2.3.0.1:

ID: 692360
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 692405
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 696580
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59372_1.fw(573)

Version 2.2.0.1:

ID: 668610
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688760 / Support ID:400299371
Loss of safety connection
Loss of safety connection, eventhough the parametrized "safe data duration"is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689710
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689900
Increased delay of external feedback error detection
Increased delay of external feedback error detection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689945
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690005
Improvement of the feedbackdiagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690090
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59372_1.fw(571)

Version 2.1.0.0:

ID: 644265
major (even incompatible) changes for mapp Safety
First upgradefor mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\59372_1.fw(570)

Version 1.10.9.1:

ID: 643160
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59372_1.fw(330)

Version 1.10.9.0:

ID:618280
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59372_1.fw(330)

Version 1.10.2.2:

ID: 537515 / Support ID: 400220092
Show consumed SRT cycle time
Show consumed SRT cycle time
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 541770
New default values
Default values for discrepancytime ans filter on changed
Channeldescription changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 542350 / Support ID: 400221738
Correction of the Feedback evaluation
Correction in the evaluation of the SO-feedbacks.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 552365
User configurable Toff filter, new default value
Toff filter is now configurable to 0us. A "filter on" value of less than 1000us in combination with "Pulse Mode internal" can lead to unintended deactivation or troggling of the safe input. For existing projects this has to be verified.
Default value changed to 1000us.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 554670 / Support ID: 400228406
ChannelOk reset with OSSD-Signals near the SRT-Cycletime
OSSD-signals similar to the SRT-cycletime cause channel errors. With the change the ChannelOk remains high and filters can be applied.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 557005 / Support ID: 400230951
Fix the output channel in combined SRT- and SC-mode
Fix the out channel if an output is set by the SRT and the SC-part of the module
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 558620
Correction of the parameter download
Correction of the parameter download to the SRT-module
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59372_1.fw(327)

Version 1.10.1.0:

ID: 530020
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59372_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.3.0.1 * 01/12/2020 2 Mo EXE AS4_HW_X20SRT842.exe
Description V4.6 HW Upgrade (X20SRT842)

Revision information X20SRT402

Version 2.3.0.1:

ID: 692360
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed:Yes

ID: 692405
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 696580
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59372_1.fw(573)

Version 2.2.0.1:

ID: 668610
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmwarechanged: No

ID: 688760 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689710
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689900
Increased delay of external feedback error detection
Increaseddelay of external feedback error detection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689945
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690005
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690090
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configurationdescription changed: No
Firmware changed: No
Firmware: 10\59372_1.fw(571)

Version 2.1.0.0:

ID: 644265
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety"in help!
Channel description changed: Yes
Configuration descriptionchanged: Yes
Firmware changed: Yes
Firmware: 10\59372_1.fw(570)

Version 1.10.9.1:

ID: 643160
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59372_1.fw(330)

Version 1.10.9.0:

ID: 618280
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with largeprojects.
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes
Firmware: 1\59372_1.fw(330)

Version 1.10.2.2:

ID: 537515 / Support ID: 400220092
Show consumed SRT cycle time
Show consumed SRT cycle time
Channel descriptionchanged: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 541770
New default values
Default values for discrepancytime ans filter on changed
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 542350 / Support ID: 400221738
Correction of the Feedback evaluation
Correction in the evaluation of the SO-feedbacks.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 552365
User configurable Toff filter, new default value
Toff filter is now configurable to 0us. A "filter on" value of less than 1000us in combination with "Pulse Mode internal" can lead to unintended deactivation or troggling of the safe input. For existing projects this has to be verified.
Default value changed to 1000us.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 554670 / Support ID: 400228406
ChannelOk reset with OSSD-Signals near the SRT-Cycletime
OSSD-signals similar to the SRT-cycletime cause channel errors. With the change the ChannelOk remains high and filters can be applied.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 557005 / Support ID: 400230951
Fix the output channel in combined SRT- and SC-mode
Fix the out channel if an output is set by the SRT and the SC-part of the module
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 558620
Correction of the parameter download
Correction of the parameter download to the SRT-module
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59372_1.fw(327)

Version 1.10.1.0:

ID: 530020
first official release
first official release
Channeldescription changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59372_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.2.0.1 * 21/07/2020 2 Mo EXE AS4_HW_X20SRT842.exe
Description V4.6 HW Upgrade (X20SRT842)

Revision information X20SRT402

Version 2.2.0.1:

ID: 668610
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688760 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689710
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689900
Increased delay of external feedback error detection
Increased delay of external feedback error detection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689945
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690005
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690090
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware:10\59372_1.fw(571)

Version 2.1.0.0:

ID: 644265
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching tomapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\59372_1.fw(570)

Version 1.10.9.1:

ID: 643160
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59372_1.fw(330)

Version 1.10.9.0:

ID: 618280
loggerentry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59372_1.fw(330)

Version 1.10.2.2:

ID: 537515 / Support ID: 400220092
Show consumed SRT cycle time
Show consumed SRT cycle time
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 541770
New default values
Default values for discrepancytime ans filter on changed
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 542350 / Support ID: 400221738
Correction of the Feedback evaluation
Correction in the evaluation of the SO-feedbacks.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 552365
User configurable Toff filter, new default value
Toff filter is now configurable to 0us. A "filter on" value of less than 1000us in combination with "Pulse Mode internal" can lead to unintended deactivation or troggling of the safe input. For existing projects this hasto be verified.
Default value changed to 1000us.
Channel description changed: No
Configuration description changed: Yes
Firmware changed:Yes

ID: 554670 / Support ID: 400228406
ChannelOk reset with OSSD-Signals near the SRT-Cycletime
OSSD-signals similar to the SRT-cycletime cause channel errors. With the change the ChannelOk remains high and filterscan be applied.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 557005 / Support ID: 400230951
Fix the output channel in combined SRT- and SC-mode
Fix the out channel if an output is set by the SRT and the SC-part of the module
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 558620
Correction of the parameter download
Correction of the parameter download to the SRT-module
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59372_1.fw(327)

Version 1.10.1.0:

ID: 530020
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59372_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.1.0.0 * 05/07/2019 2 Mo EXE AS4_HW_X20SRT842.exe
Description V4.6 HW Upgrade (X20SRT842)

Revision information X20SRT402

Version 2.1.0.0:

ID: 644265
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\59372_1.fw(570)

Version 1.10.9.1:

ID: 643160
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59372_1.fw(330)

Version 1.10.9.0:

ID: 618280
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59372_1.fw(330)

Version 1.10.2.2:

ID: 537515 / Support ID: 400220092
Show consumed SRT cycle time
Show consumed SRT cycle time
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID:541770
New default values
Default values for discrepancytime ans filter on changed
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 542350 / Support ID:400221738
Correction of the Feedback evaluation
Correction in the evaluation of the SO-feedbacks.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 552365
User configurable Toff filter, new default value
Toff filter is now configurable to 0us. A "filter on" value of less than 1000us in combination with "Pulse Mode internal" can lead to unintended deactivation or troggling ofthe safe input. For existing projects this has to be verified.
Default value changed to 1000us.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 554670 / Support ID: 400228406
ChannelOk reset with OSSD-Signals near the SRT-Cycletime
OSSD-signals similar to the SRT-cycletime cause channel errors. With the change the ChannelOk remains high and filters can be applied.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 557005 / Support ID: 400230951
Fix the outputchannel in combined SRT- and SC-mode
Fix the out channel if an output isset by the SRT and the SC-part of the module
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 558620
Correction of the parameter download
Correction of the parameter download to the SRT-module
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59372_1.fw(327)

Version 1.10.1.0:

ID: 530020
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59372_1.fw(320)