2.6.0.1 * 05/03/2024 4 MB EXE AS4_HW_X20SLX811.exe
Description V4.6 HW Upgrade (X20SLX811)

Revision information X20SLX811

Version 2.6.0.1:

ID: 780985
Correction of the input filter with set "Filter off".
Correction of the input filter, if a "Filter off" is set and a channel error is detected.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 780990 / Support ID: 400412437
Configuration for Power Calculation available
The Configuration for Power Calculation is now available in Automation Studio
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 780995
New data sheet V2.20
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(593), 11\59223_1.fw(593)

Version 2.4.3.0:

ID: 765145
SafeDomain to SafeDomain communication with differing "Process data transfer rate" setting
SafeDomain to SafeDomain communication could not be established if "Processdata transfer rate"setting differed between Managing and Connected SafeDomain.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59223_1.fw(592), 11\59223_1.fw(592)

Version 2.4.2.0:

ID: 754870
data sheet V2.15
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:No

ID: 756470
online project compare
Activation of SafeDESIGNER option "Download project source to SL (online project compare)" didn't have any effect (requires mappSafety 5.15).
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 756475
logger messages "Inconsistent UDID files" / "Set-to-operational for unacknowledged UDID"
Fix -1073552872 "Inconsistent UDID files" /-1073552680 "Set-to-operational for unacknowledged UDID" (fix available for AR >= B4.92)
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 756480
"CLEAR DATA" Safe Commissioning Options
"CLEAR DATA" did not delete the data for Safe Commissioning Options with data types SAFEINT, SAFEDINT and SAFEDWORD (fix available for AR >= B4.92).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 756485
Safe Commissioning Options without SAFEBOOL
Logger message "external machine options discrepancy" was triggered by mistake when Safe Commissioning Options where used without using any channel SafeCommissioningOptionsBITxxx
(fix available for AR >= B4.92)
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(591), 11\59223_1.fw(591)

Version 2.4.1.1:

ID: 731365
data sheet V2.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 731370
The power calculation of the modules is supported
The data for the power calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(590)

Version 2.4.0.0:

ID: 707765
data sheet V2.08
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 707770
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707775
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707780
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 707785
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707790
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes

ID: 707795
Variable status issue
Having Variable status active for a long time could lead to SLX failsafe state with certain projects (logger entries 110337/114433 respectively -1073561855/-1073565951).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707800
SafeDOMAIN-to-SafeDOMAIN communication: Connected SafeDOMAIN
Provide a Connected SafeDOMAIN (required minimum versions: Automation Runtime A4.90, mappSafety 5.13, X20(c)SL81xx V2.3.0.0)
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 707810
Technical data: "Communication with each other": Generalized statement regarding the CPU used
Technical data: "Communication with eachother": Generalized statement regarding the CPU used
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:No
Firmware: 10\59223_1.fw(590)

Version 2.2.0.0:

ID: 674115
Safe Commissioning Options
support additional data types
ATTENTION:
- requires AR E4.71 or A4.72 and mappSafety 5.8 or higher
- at least one Safe Commissioning Option with data type BOOL must be used also
- use SafeKEY FORMAT to remove Safe Commissioning Options with data types other than BOOL from target
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 677590
SafeDOMAIN-to-SafeDOMAIN communication
Support SafeDOMAIN-to-SafeDOMAINcommunication between SafeLOGIC and SafeLOGIC-X (requires mappSafety 5.10 or higher)
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 677595
data sheet V2.05
Channel description changed: No
Configuration description changed:No
Firmware changed: No
Firmware: 10\59223_1.fw(580)

Version2.1.0.4:

ID: 668575
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(570)

Version 2.1.0.3:

ID: 637415
new AR targets
support new AR targets X20CPx68x and xPC22xx
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(570)

Version 2.1.0.1:

ID: 541680
major (even incompatible) changes for mapp Safety

First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!

Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 628070
safety response time

The check of the network transmission time of cyclic data tolerated values up to 12ms higher than configuredby the parameters "safe data duration"/"additional tolerated packet loss".
This could lead to an increased safety response time.

Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 644585
Setup Mode signaling
Setup Mode is now signaled with "S" and "E" LED.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59223_1.fw(570)

Version 1.10.10.3:

ID: 626170
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 637425
fix logger entry 123622
SLX didn't enter RUN state and logger number 123622 was entered when using 10 other safety modules.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.10.1:

ID: 637415
new AR targets
support new AR targets X20CPx68x and xPC22xx
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 637425
fix logger entry 123622
SLX didn't enter RUN state and logger number123622 was entered when using 10 other safety modules.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.10.0:

ID: 626170
safety response time
The check of the network transmission time of cyclic data tolerated values up to 12ms higher than configured by the parameters "safe data duration"/"additional tolerated packet loss".
This could lead to an increased safety response time.
Channel description changed:No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.9.0:

ID: 618245
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(330)

Version 1.10.5.0:

ID: 582825
logger message 106773
Fix for logger message 106773 "Parameter checksum sizes do not match".
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(326)

Version 1.10.4.1:

ID: 577400
Increase the tolerance of the voltagemonitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 598860
extended operating temperature range
Firmware preparation for hardware revisions that allow operating temperature range down to -40°C.
Channel description changed: No
Configuration description changed: No
Firmwarechanged: Yes

ID: 598875 / Support ID: 400208127
channel error when wired to +24V
Temporary channel errors (logger entry 115011) are reported if If channels are wired to +24V during module bootup.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598885 / Support ID: 400208284, 400210471
logger message 110356
Logger message 110356 was generated by mistake during bootup.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598895
fix CLEAR DATA
Not all relevant data has been deleted upon command "CLEAR DATA"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598905 / Support ID: 400229868, 400229876
logger entry 123432
fixed logger entry 123432 when using setup mode in combination with machineoptions
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598910 / Support ID: 400221412, 400225768
bootup time
increase of bootup time with Upgrade V1.10.2.9
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598915
increased tolerance against asynchronous communication problems
Problems in asynchronous communication to safety modules now cause the modules to be rated as "missing" not until the "Node Guarding Timeout" has expired(instead of after a few seconds)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598920
additional parameters
Support additonal parameters (AsSafety FBK safeDownloadData_V2.Type=safeDATA_TYPE_ADDPARA); requires AR >= A04.41 !
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(326)

Version 1.10.3.2:

ID: 550480 / Support ID: 400225917
Correction of SLX download frame
Correction of SLX download frame
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(324)

Version 1.10.3.1:

ID: 538795
logger message 110367 with external maschine options
SLX did not boot correctly when using external machine options with upgradeV1.10.2.9 (logger message 110367 and others).
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 538800
logger message 123416 when aknowledging a firmware mismatch
The command for firmware acknowledgement was accepted although there was still a SCAN in progress. This could lead to a failure with logger message 123416.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(324)

Version 1.10.2.9:

ID: 523075
fixes for parameters in SafeDESIGNER
Minor text corrections.
Remove obsolete parameter "Cycle time".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 523080
Adapt filter algorithm to eliminate dependencies betweenTON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 523085
warn about invalid two channel processing mode
SafeDESIGNER generates a warning during compile if a two-channel evaluationchannel is used but the according parameter "Two Channel Processing Mode" is "none".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 523090
support lower "Safe Data Duration" values
Internal optimizations lead to support of lower values for "Safe Data Duration"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 523095
support Acopos P3
support all variants of Acopos P3
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 524895
Setup Mode and automated acknowledgements
- Setup Mode is supported (requires SafeDESIGNER 4.3 and AutomationRuntime B4.26 or higher)
- new parameters for automated acknowledgement of SafeKEY and firmware exchange.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 524900
Error while downloading big SafeDESIGNER applications to the SLX.
Download was aborted and the message "File Unlock Status: Error while writing unlock status!" was shown.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 528965
SafeOS Status in SafeDESIGNER Remote Control
It is a known issue that the SafeOS status in SafeDESIGNER remote control is not shown correctlywhen using certain versions.
SafeDESIGNER SafePLC window or AsSafety can be used instead.
This affects a set of following versions:
SLX Upgrade >=V1.10.2.x, Safety Release 1.10, SafeDESIGNER >=V4.2.3
and AR B4.26 toC4.26 or C4.33 to E4.33
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 529975
Update Online Help
Update Online Help V1.110
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(324)

Version 1.10.1.2:

ID: 495585
Update online help to V1.103
Update online help to V1.103
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 499055
Improve SLX cycle time
Performance optimization for improvement of internal SLX cycle time.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 499060
SLXbootState 54
SLXbootState never reached value 54 "SafeRUN" although SLX booted correctly.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(322)

Version 1.10.0.0:

ID: 485265
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.4.3.0 * 01/03/2023 4 MB EXE AS4_HW_X20SLX811.exe
Description V4.6 HW Upgrade (X20SLX811)

Revision information X20SLX811

Version 2.4.3.0:

ID: 765145
SafeDomain to SafeDomain communication with differing "Process data transfer rate" setting
SafeDomain to SafeDomain communication could not be established if "Processdata transfer rate" setting differed between Managing and Connected SafeDomain.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59223_1.fw(592), 11\59223_1.fw(592)

Version 2.4.2.0:

ID: 754870
data sheet V2.15
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 756470
online project compare
Activation of SafeDESIGNERoption "Download project source to SL (online project compare)" didn't have any effect (requires mappSafety 5.15).
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 756475
logger messages "Inconsistent UDID files" / "Set-to-operational for unacknowledged UDID"
Fix -1073552872 "Inconsistent UDID files" / -1073552680 "Set-to-operationalfor unacknowledged UDID" (fix available for AR >= B4.92)
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 756480
"CLEAR DATA" Safe Commissioning Options
"CLEAR DATA" did not delete the data for Safe Commissioning Options with data types SAFEINT, SAFEDINT and SAFEDWORD (fix available for AR >= B4.92).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 756485
Safe Commissioning Options without SAFEBOOL
Logger message "external machine options discrepancy" was triggered by mistake when Safe Commissioning Options where used without using any channel SafeCommissioningOptionsBITxxx
(fix available for AR >= B4.92)
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(591), 11\59223_1.fw(591)

Version 2.4.1.1:

ID: 731365
data sheet V2.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 731370
The power calculation of the modules is supported
The data for the powercalculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(590)

Version 2.4.0.0:

ID: 707765
data sheet V2.08
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 707770
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707775
The OSDD signal at the pulse outputis corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707780
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration descriptionchanged: Yes
Firmware changed: Yes

ID: 707785
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707790
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707795
Variable status issue
Having Variable status active for a long time could lead to SLX failsafe state with certain projects (logger entries 110337/114433 respectively -1073561855/-1073565951).
Channel description changed: No
Configurationdescription changed: No
Firmware changed: Yes

ID: 707800
SafeDOMAIN-to-SafeDOMAIN communication: Connected SafeDOMAIN
Provide a Connected SafeDOMAIN (required minimum versions: Automation Runtime A4.90, mappSafety 5.13, X20(c)SL81xx V2.3.0.0)
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 707810
Technical data: "Communication with each other": Generalized statement regarding the CPU used
Technical data: "Communication with each other": Generalized statement regarding the CPU used
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(590)

Version 2.2.0.0:

ID: 674115
Safe Commissioning Options
support additional data types
ATTENTION:
- requires AR E4.71 or A4.72 and mappSafety 5.8 or higher
- at leastone Safe Commissioning Option with data type BOOL must be used also
- useSafeKEY FORMAT to remove Safe Commissioning Options with data types other than BOOL from target
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 677590
SafeDOMAIN-to-SafeDOMAIN communication
Support SafeDOMAIN-to-SafeDOMAIN communication between SafeLOGIC and SafeLOGIC-X (requires mappSafety 5.10 or higher)
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 677595
data sheet V2.05
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(580)

Version 2.1.0.4:

ID: 668575
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(570)

Version 2.1.0.3:

ID: 637415
new AR targets
support new AR targets X20CPx68x and xPC22xx
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(570)

Version 2.1.0.1:

ID: 541680
major (even incompatible) changes for mapp Safety

First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!

Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 628070
safety response time

The check of the network transmission time of cyclic data tolerated values up to 12ms higher than configured by the parameters "safe data duration"/"additional tolerated packet loss".
This could lead to an increased safety response time.

Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 644585
Setup Mode signaling
Setup Mode is now signaled with "S" and "E" LED.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59223_1.fw(570)

Version 1.10.10.3:

ID: 626170
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 637425
fix logger entry 123622
SLX didn't enter RUN state and logger number 123622 was entered when using 10 other safety modules.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.10.1:

ID: 637415
new AR targets
support new AR targets X20CPx68x and xPC22xx
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 637425
fix logger entry 123622
SLX didn't enter RUN state and logger number 123622 was entered when using 10 other safety modules.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.10.0:

ID: 626170
safety response time
The check of the network transmission time ofcyclic data tolerated values up to 12ms higher than configured by the parameters "safe data duration"/"additional tolerated packet loss".
This could lead to an increased safety response time.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.9.0:

ID: 618245
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(330)

Version 1.10.5.0:

ID: 582825
logger message 106773
Fix for logger message 106773 "Parameter checksum sizes do not match".
Channel description changed: No
Configuration description changed:No
Firmware changed: Yes
Firmware: 1\59223_1.fw(326)

Version1.10.4.1:

ID: 577400
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 598860
extended operating temperature range
Firmware preparation for hardware revisions that allow operating temperature range down to -40°C.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598875 / Support ID: 400208127
channel error when wired to +24V
Temporary channel errors (logger entry 115011) are reported if If channels are wired to +24V during module bootup.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598885 / Support ID: 400208284, 400210471
logger message 110356
Logger message 110356 was generated by mistake during bootup.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598895
fix CLEAR DATA
Not all relevant data has been deleted upon command "CLEAR DATA"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598905 / Support ID: 400229868, 400229876
logger entry 123432
fixed logger entry 123432 when using setup mode in combination with machineoptions
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598910 / Support ID: 400221412, 400225768
bootup time
increase of bootup time with Upgrade V1.10.2.9
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598915
increased tolerance against asynchronous communication problems
Problems in asynchronous communication to safety modules now cause the modules to be ratedas "missing" not until the "Node Guarding Timeout" has expired (instead of after a few seconds)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598920
additional parameters
Support additonal parameters (AsSafety FBK safeDownloadData_V2.Type=safeDATA_TYPE_ADDPARA); requires AR >= A04.41 !
Channel description changed: No
Configuration description changed: No
Firmwarechanged: Yes
Firmware: 1\59223_1.fw(326)

Version 1.10.3.2:

ID: 550480 / Support ID: 400225917
Correction of SLX download frame
Correction of SLX download frame
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware:1\59223_1.fw(324)

Version 1.10.3.1:

ID: 538795
logger message 110367 with external maschine options
SLX did not boot correctly when using external machine options with upgradeV1.10.2.9 (logger message 110367 and others).
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 538800
logger message 123416 when aknowledging a firmware mismatch
The command for firmware acknowledgement was accepted although there was still a SCAN in progress. This could lead to a failure with logger message 123416.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(324)

Version 1.10.2.9:

ID: 523075
fixes for parameters in SafeDESIGNER
Minor text corrections.
Remove obsolete parameter "Cycle time".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 523080
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 523085
warn about invalid two channel processing mode
SafeDESIGNER generates a warning during compile if a two-channel evaluationchannel is used but the according parameter "Two Channel Processing Mode" is "none".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 523090
support lower "Safe Data Duration" values
Internal optimizations lead to support of lowervalues for "Safe Data Duration"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 523095
support Acopos P3
support all variants of Acopos P3
Channeldescription changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 524895
Setup Mode and automated acknowledgements
- Setup Mode is supported (requires SafeDESIGNER 4.3 and AutomationRuntime B4.26 or higher)
- new parameters for automated acknowledgement ofSafeKEY and firmware exchange.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 524900
Error while downloading big SafeDESIGNER applications to the SLX.
Download was aborted and the message "File Unlock Status: Error while writing unlock status!" was shown.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 528965
SafeOS Status in SafeDESIGNER Remote Control
It is a known issue that the SafeOS status in SafeDESIGNER remote control is not shown correctly whenusing certain versions.
SafeDESIGNER SafePLC window or AsSafety can be used instead.
This affects a set of following versions:
SLX Upgrade >=V1.10.2.x, Safety Release 1.10, SafeDESIGNER >=V4.2.3
and AR B4.26 to C4.26 or C4.33 to E4.33
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 529975
Update Online Help
Update Online Help V1.110
Channel description changed:No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(324)

Version 1.10.1.2:

ID: 495585
Update online help to V1.103
Update online help to V1.103
Channel description changed: No
Configuration description changed: No
Firmwarechanged: No

ID: 499055
Improve SLX cycle time
Performance optimization for improvement of internal SLX cycle time.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 499060
SLXbootState 54
SLXbootState never reached value 54 "SafeRUN" although SLX booted correctly.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(322)

Version 1.10.0.0:

ID: 485265
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.4.2.0 * 08/09/2022 4 MB EXE AS4_HW_X20SLX811.exe
Description V4.6 HW Upgrade (X20SLX811)

Revision information X20SLX811

Version 2.4.2.0:

ID: 754870
data sheet V2.15
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 756470
online project compare
Activation of SafeDESIGNER option "Download project source to SL (online project compare)" didn't have any effect (requires mappSafety 5.15).
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 756475
logger messages "Inconsistent UDID files" / "Set-to-operational for unacknowledged UDID"
Fix -1073552872 "Inconsistent UDID files" / -1073552680 "Set-to-operationalfor unacknowledged UDID" (fix available for AR >= B4.92)
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 756480
"CLEAR DATA" Safe Commissioning Options
"CLEAR DATA" did not delete the data for Safe Commissioning Options with data types SAFEINT, SAFEDINT and SAFEDWORD (fixavailable for AR >= B4.92).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 756485
Safe Commissioning Options without SAFEBOOL
Logger message "external machine options discrepancy" was triggered by mistake when Safe Commissioning Options where used without using any channel SafeCommissioningOptionsBITxxx
(fix available for AR >= B4.92)
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(591), 11\59223_1.fw(591)

Version 2.4.1.1:

ID: 731365
data sheet V2.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 731370
The power calculation of the modules is supported
The data for thepower calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(590)

Version 2.4.0.0:

ID: 707765
data sheet V2.08
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 707770
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707775
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707780
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 707785
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis ofthe output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707790
Improvementof the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707795
Variable status issue
Having Variable status active for a long time could lead to SLXfailsafe state with certain projects (logger entries 110337/114433 respectively -1073561855/-1073565951).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707800
SafeDOMAIN-to-SafeDOMAIN communication: Connected SafeDOMAIN
Providea Connected SafeDOMAIN (required minimum versions: Automation Runtime A4.90, mappSafety 5.13, X20(c)SL81xx V2.3.0.0)
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 707810
Technical data: "Communication with each other": Generalizedstatement regarding the CPU used
Technical data: "Communication with each other": Generalized statement regarding the CPU used
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(590)

Version 2.2.0.0:

ID: 674115
Safe Commissioning Options
support additional data types
ATTENTION:
- requires AR E4.71 or A4.72 and mappSafety 5.8 or higher
- atleast one Safe Commissioning Option with data type BOOL must be used also
- use SafeKEY FORMAT to remove Safe Commissioning Options with data types other than BOOL from target
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 677590
SafeDOMAIN-to-SafeDOMAIN communication
Support SafeDOMAIN-to-SafeDOMAIN communication between SafeLOGIC and SafeLOGIC-X (requires mappSafety 5.10 orhigher)
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 677595
data sheet V2.05
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(580)

Version 2.1.0.4:

ID: 668575
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(570)

Version 2.1.0.3:

ID: 637415
new AR targets
support new AR targets X20CPx68x and xPC22xx
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(570)

Version 2.1.0.1:

ID: 541680
major (even incompatible) changes for mapp Safety

First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching tomapp Safety" in help!

Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 628070
safety response time

The check of the network transmission time of cyclic data tolerated values up to 12ms higher than configured by the parameters "safe data duration"/"additional tolerated packet loss".
This could lead to an increased safety response time.

Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 644585
Setup Mode signaling
Setup Mode is now signaled with "S" and "E" LED.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59223_1.fw(570)

Version 1.10.10.3:

ID: 626170
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 637425
fix logger entry 123622
SLX didn't enter RUN state and logger number 123622 was entered when using 10 other safetymodules.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.10.1:

ID: 637415
new AR targets
support new ARtargets X20CPx68x and xPC22xx
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 637425
fix logger entry 123622
SLX didn't enter RUN state and logger number 123622 was entered when using 10 other safety modules.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.10.0:

ID:626170
safety response time
The check of the network transmission time of cyclic data tolerated values up to 12ms higher than configured by the parameters "safe data duration"/"additional tolerated packet loss".
This could lead to an increased safety response time.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.9.0:

ID: 618245
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(330)

Version 1.10.5.0:

ID: 582825
logger message 106773
Fix for logger message 106773 "Parameter checksum sizes do not match".
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(326)

Version 1.10.4.1:

ID: 577400
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 598860
extended operating temperature range
Firmware preparation for hardware revisions that allow operating temperature range down to -40°C.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598875 / Support ID: 400208127
channel error when wired to +24V
Temporary channel errors (logger entry 115011) are reported if If channels are wired to +24V during module bootup.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598885 / Support ID: 400208284, 400210471
loggermessage 110356
Logger message 110356 was generated by mistake during bootup.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598895
fix CLEAR DATA
Not all relevant data has been deleted upon command "CLEAR DATA"
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598905 / Support ID: 400229868, 400229876
logger entry 123432
fixed logger entry 123432 when using setup mode in combination with machineoptions
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598910/ Support ID: 400221412, 400225768
bootup time
increase of bootup time with Upgrade V1.10.2.9
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598915
increased tolerance against asynchronous communication problems
Problems in asynchronous communication to safety modules now cause the modules to berated as "missing" not until the "Node Guarding Timeout" has expired (insteadof after a few seconds)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598920
additional parameters
Support additonal parameters (AsSafety FBK safeDownloadData_V2.Type=safeDATA_TYPE_ADDPARA); requires AR >= A04.41 !
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(326)

Version 1.10.3.2:

ID: 550480 / Support ID: 400225917
Correction of SLX download frame
Correction of SLX download frame
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(324)

Version 1.10.3.1:

ID: 538795
logger message 110367 with external maschine options
SLX did not boot correctly when using external machine options with upgradeV1.10.2.9 (logger message110367 and others).
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 538800
logger message 123416 when aknowledging a firmware mismatch
The command for firmware acknowledgement was accepted although there was still a SCAN in progress. This could lead to a failure with logger message 123416.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(324)

Version 1.10.2.9:

ID: 523075
fixes for parameters in SafeDESIGNER
Minor text corrections.
Remove obsolete parameter "Cycle time".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 523080
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 523085
warn about invalid two channel processing mode
SafeDESIGNER generates a warning during compile if a two-channel evaluationchannel is used but the according parameter "Two Channel Processing Mode" is "none".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 523090
support lower "Safe Data Duration" values
Internal optimizations lead to support oflower values for "Safe Data Duration"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 523095
support Acopos P3
support all variants of Acopos P3
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 524895
Setup Mode and automated acknowledgements
- Setup Mode is supported (requires SafeDESIGNER 4.3 and AutomationRuntime B4.26 or higher)
- new parameters for automated acknowledgement of SafeKEY and firmware exchange.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 524900
Error while downloading big SafeDESIGNER applications to the SLX.
Download was aborted and the message "File Unlock Status: Error while writing unlock status!" was shown.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 528965
SafeOS Status in SafeDESIGNER Remote Control
It is a known issue that the SafeOS status in SafeDESIGNER remote control is not shown correctly when using certain versions.
SafeDESIGNER SafePLC window or AsSafety can be used instead.
This affects a set of following versions:
SLX Upgrade >=V1.10.2.x, Safety Release 1.10, SafeDESIGNER >=V4.2.3
and AR B4.26 to C4.26 or C4.33 to E4.33
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 529975
Update Online Help
Update Online Help V1.110
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(324)

Version 1.10.1.2:

ID: 495585
Update online help to V1.103
Update online help to V1.103
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 499055
Improve SLX cycle time
Performance optimization for improvement of internal SLX cycle time.
Channel description changed: No
Configuration description changed: No
Firmwarechanged: Yes

ID: 499060
SLXbootState 54
SLXbootState neverreached value 54 "SafeRUN" although SLX booted correctly.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(322)

Version 1.10.0.0:

ID: 485265
first official release
first official release
Channeldescription changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.4.1.1 * 18/08/2021 3 MB EXE AS4_HW_X20SLX811.exe
Description V4.6 HW Upgrade (X20SLX811)

Revision information X20SLX811

Version 2.4.1.1:

ID: 731365
data sheet V2.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 731370
The power calculation of the modules is supported
The data for the power calculation of the data sheet is included in theHWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(590)

Version 2.4.0.0:

ID: 707765
data sheet V2.08
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 707770
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707775
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707780
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 707785
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707790
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707795
Variable status issue
Having Variable status active for a longtime could lead to SLX failsafe state with certain projects (logger entries 110337/114433 respectively -1073561855/-1073565951).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707800
SafeDOMAIN-to-SafeDOMAIN communication: Connected SafeDOMAIN
Provide a Connected SafeDOMAIN (required minimum versions: Automation Runtime A4.90, mappSafety 5.13, X20(c)SL81xx V2.3.0.0)
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 707810
Technical data: "Communication with each other": Generalized statement regarding the CPU used
Technical data: "Communication with each other": Generalized statement regarding the CPU used
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(590)

Version 2.2.0.0:

ID: 674115
Safe Commissioning Options
support additional data types
ATTENTION:
- requires AR E4.71 or A4.72 and mappSafety5.8 or higher
- at least one Safe Commissioning Option with data type BOOL must be used also
- use SafeKEY FORMAT to remove Safe Commissioning Options with data types other than BOOL from target
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 677590
SafeDOMAIN-to-SafeDOMAIN communication
Support SafeDOMAIN-to-SafeDOMAIN communication between SafeLOGIC and SafeLOGIC-X (requires mappSafety 5.10 or higher)
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 677595
data sheet V2.05
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(580)

Version 2.1.0.4:

ID: 668575
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(570)

Version 2.1.0.3:

ID: 637415
new AR targets
support new AR targets X20CPx68x and xPC22xx
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(570)

Version 2.1.0.1:

ID: 541680
major (even incompatible) changes for mapp Safety

First upgrade formapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!

Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 628070
safety response time

The check of the network transmission time of cyclic data tolerated values up to 12ms higher than configured by the parameters "safe data duration"/"additional tolerated packet loss".
This could lead to an increased safety response time.

Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 644585
SetupMode signaling
Setup Mode is now signaled with "S" and "E" LED.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59223_1.fw(570)

Version 1.10.10.3:

ID: 626170
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 637425
fix logger entry 123622
SLX didn't enter RUN state and logger number 123622 was entered when using 10 other safety modules.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.10.1:

ID: 637415
new AR targets
support new AR targets X20CPx68x and xPC22xx
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:No

ID: 637425
fix logger entry 123622
SLX didn't enter RUNstate and logger number 123622 was entered when using 10 other safety modules.
Channel description changed: No
Configuration description changed:No
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.10.0:

ID: 626170
safety response time
The check of thenetwork transmission time of cyclic data tolerated values up to 12ms higher than configured by the parameters "safe data duration"/"additional tolerated packet loss".
This could lead to an increased safety response time.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.9.0:

ID: 618245
logger entry 112174, 108078
Logger entry 112174,108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(330)

Version 1.10.5.0:

ID: 582825
logger message 106773
Fix for logger message 106773 "Parameterchecksum sizes do not match".
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(326)

Version 1.10.4.1:

ID: 577400
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor wasincreased to prevent sporadic falseerrors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 598860
extended operating temperature range
Firmware preparation for hardware revisions that allow operating temperature range down to -40°C.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598875 / Support ID: 400208127
channel error when wired to +24V
Temporary channel errors (logger entry 115011) are reported if If channels are wired to +24V during module bootup.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598885 / Support ID: 400208284, 400210471
logger message 110356
Logger message 110356 was generated by mistake during bootup.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598895
fix CLEAR DATA
Not all relevant data has been deleted upon command "CLEAR DATA"
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes

ID: 598905 / Support ID: 400229868, 400229876
logger entry 123432
fixed logger entry 123432 when using setup mode in combination with machineoptions
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598910 / Support ID: 400221412, 400225768
bootup time
increase of bootup time with Upgrade V1.10.2.9
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598915
increased tolerance against asynchronous communication problems
Problems in asynchronous communication to safety modules now cause the modules to be rated as "missing" not until the "Node Guarding Timeout" has expired(instead of after a few seconds)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598920
additional parameters
Support additonal parameters (AsSafety FBK safeDownloadData_V2.Type=safeDATA_TYPE_ADDPARA); requires AR >= A04.41 !
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(326)

Version 1.10.3.2:

ID: 550480 / Support ID: 400225917
Correction of SLX download frame
Correction of SLX download frame
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(324)

Version 1.10.3.1:

ID: 538795
logger message 110367 with external maschine options
SLX did not boot correctly when using external machine options with upgradeV1.10.2.9 (logger message 110367 and others).
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 538800
logger message 123416 when aknowledging a firmware mismatch
The command for firmware acknowledgement was accepted although there wasstill a SCAN in progress. This could lead to a failure with logger message 123416.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(324)

Version 1.10.2.9:

ID: 523075
fixes for parameters in SafeDESIGNER
Minor text corrections.
Remove obsolete parameter "Cycle time".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 523080
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 523085
warn about invalid two channel processing mode
SafeDESIGNER generates a warning during compile if a two-channel evaluationchannel is used but the according parameter "TwoChannel Processing Mode" is "none".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID:523090
support lower "Safe Data Duration" values
Internal optimizations lead to support of lower values for "Safe Data Duration"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 523095
support Acopos P3
support all variants of Acopos P3
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 524895
Setup Mode and automated acknowledgements
- Setup Mode is supported (requires SafeDESIGNER 4.3 and AutomationRuntime B4.26 or higher)
- new parameters forautomated acknowledgement of SafeKEY and firmware exchange.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 524900
Error while downloading big SafeDESIGNERapplications to the SLX.
Download was aborted and the message "File Unlock Status: Error while writing unlock status!" was shown.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 528965
SafeOS Status in SafeDESIGNER Remote Control
It is a known issue that the SafeOS status in SafeDESIGNER remote control is not shown correctly when using certain versions.
SafeDESIGNER SafePLC window or AsSafety can be used instead.
This affects a set of following versions:
SLX Upgrade >=V1.10.2.x, Safety Release 1.10, SafeDESIGNER >=V4.2.3
and AR B4.26 to C4.26 or C4.33 to E4.33
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 529975
Update Online Help
Update Online Help V1.110
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(324)

Version 1.10.1.2:

ID: 495585
Update online help to V1.103
Update online help to V1.103
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 499055
Improve SLXcycle time
Performance optimization for improvement of internal SLX cycle time.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 499060
SLXbootState 54
SLXbootState never reached value 54 "SafeRUN" although SLX booted correctly.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(322)

Version 1.10.0.0:

ID: 485265
first official release
first official release
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: No
Firmware: 1\59223_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.4.0.0 * 01/12/2020 3 MB EXE AS4_HW_X20SLX811.exe
Description V4.6 HW Upgrade (X20SLX811)

Revision information X20SLX811

Version 2.4.0.0:

ID: 707765
data sheet V2.08
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 707770
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than thenetwork failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707775
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707780
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 707785
Improvement of the feedback diagnosis.
Improvement of thefeedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707790
Improvement of the internal voltage monitoring.
Improvement ofthe internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707795
Variable status issue
Having Variable status active for a long time could lead to SLX failsafe state with certain projects (logger entries 110337/114433 respectively -1073561855/-1073565951).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 707800
SafeDOMAIN-to-SafeDOMAIN communication: Connected SafeDOMAIN
Provide a Connected SafeDOMAIN (required minimum versions: Automation Runtime A4.90, mappSafety 5.13, X20(c)SL81xx V2.3.0.0)
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 707810
Technical data: "Communication with each other": Generalized statement regarding the CPU used
Technical data: "Communication with each other": Generalized statement regarding the CPU used
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(590)

Version 2.2.0.0:

ID: 674115
Safe Commissioning Options
support additional data types
ATTENTION:
- requires AR E4.71 or A4.72 and mappSafety 5.8 or higher
- at least one Safe Commissioning Option with data type BOOLmust be used also
- use SafeKEY FORMAT to remove Safe Commissioning Options with data types other than BOOL from target
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 677590
SafeDOMAIN-to-SafeDOMAIN communication
Support SafeDOMAIN-to-SafeDOMAIN communication between SafeLOGIC and SafeLOGIC-X (requires mappSafety 5.10 or higher)
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 677595
data sheet V2.05
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(580)

Version 2.1.0.4:

ID: 668575
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(570)

Version 2.1.0.3:

ID: 637415
new AR targets
supportnew AR targets X20CPx68x and xPC22xx
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(570)

Version 2.1.0.1:

ID: 541680
major (even incompatible) changes for mapp Safety

First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - seechapter "Switching to mapp Safety" in help!

Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 628070
safety response time

The check of the network transmission time of cyclic data tolerated values up to 12mshigher than configured by the parameters "safe data duration"/"additional tolerated packet loss".
This could lead to an increased safety response time.

Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 644585
Setup Mode signaling
Setup Mode is now signaled with "S" and "E" LED.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59223_1.fw(570)

Version 1.10.10.3:

ID: 626170
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 637425
fix logger entry 123622
SLX didn't enter RUN state and logger number 123622 was entered whenusing 10 other safety modules.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.10.1:

ID: 637415
new AR targets
support new AR targets X20CPx68x and xPC22xx
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 637425
fix logger entry 123622
SLX didn't enter RUN state and logger number 123622 was entered when using 10 other safety modules.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.10.0:

ID: 626170
safety response time
The check of the network transmission time of cyclic data tolerated values up to 12ms higher than configured by the parameters "safe data duration"/"additional tolerated packet loss".
This could lead to an increased safety response time.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.9.0:

ID: 618245
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes
Firmware: 1\59223_1.fw(330)

Version 1.10.5.0:

ID: 582825
logger message 106773
Fix for logger message 106773 "Parameter checksum sizes do not match".
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(326)

Version 1.10.4.1:

ID: 577400
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 598860
extended operating temperature range
Firmware preparation for hardware revisions that allow operating temperature range down to-40°C.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598875 / Support ID: 400208127
channel error when wired to +24V
Temporary channel errors (loggerentry 115011) are reported if If channels are wired to +24V during module bootup.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598885 / Support ID: 400208284,400210471
logger message 110356
Logger message 110356 was generatedby mistake during bootup.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598895
fix CLEAR DATA
Not all relevant data has been deleted upon command "CLEAR DATA"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598905 / Support ID: 400229868, 400229876
logger entry 123432
fixed logger entry 123432 when using setup mode in combination with machineoptions
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598910 / Support ID: 400221412, 400225768
bootup time
increase of bootup time with Upgrade V1.10.2.9
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598915
increased tolerance against asynchronous communication problems
Problems in asynchronous communication to safety modules now cause the modules to be rated as "missing" not until the "Node Guarding Timeout" has expired(instead of after a few seconds)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598920
additional parameters
Support additonal parameters(AsSafety FBK safeDownloadData_V2.Type=safeDATA_TYPE_ADDPARA); requires AR >= A04.41 !
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(326)

Version 1.10.3.2:

ID: 550480 / Support ID: 400225917
Correction of SLX download frame
Correction of SLX download frame
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(324)

Version 1.10.3.1:

ID: 538795
logger message 110367 with external maschine options
SLX did not boot correctly when using external machine options with upgradeV1.10.2.9 (logger message 110367 and others).
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 538800
logger message 123416 when aknowledging a firmware mismatch
The command for firmware acknowledgement was accepted although there was still a SCAN in progress. This could lead to a failure with logger message 123416.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(324)

Version 1.10.2.9:

ID: 523075
fixes for parameters in SafeDESIGNER
Minor text corrections.
Remove obsolete parameter "Cycle time".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 523080
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 523085
warn about invalid two channel processing mode
SafeDESIGNER generates a warning during compileif a two-channel evaluation channel is used but the according parameter "Two Channel Processing Mode" is "none".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 523090
support lower "Safe Data Duration" values
Internal optimizations lead to support of lower values for "Safe Data Duration"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 523095
support Acopos P3
support all variants of Acopos P3
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 524895
Setup Mode and automated acknowledgements
- Setup Mode is supported (requires SafeDESIGNER 4.3 and AutomationRuntime B4.26 or higher)
- new parameters for automated acknowledgement of SafeKEY and firmware exchange.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 524900
Error while downloading big SafeDESIGNER applications to the SLX.
Download was aborted and the message "File Unlock Status: Error while writing unlock status!" was shown.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 528965
SafeOS Status in SafeDESIGNER Remote Control
It is a known issue that the SafeOS status in SafeDESIGNER remote controlisnot shown correctly when using certain versions.
SafeDESIGNER SafePLC window or AsSafety can be used instead.
This affects a set of following versions:
SLX Upgrade >=V1.10.2.x, Safety Release 1.10, SafeDESIGNER >=V4.2.3
and AR B4.26 to C4.26 or C4.33 to E4.33
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 529975
Update Online Help
Update Online Help V1.110
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(324)

Version 1.10.1.2:

ID: 495585
Update online help to V1.103
Update online help to V1.103
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 499055
Improve SLX cycle time
Performance optimization for improvement of internal SLX cycletime.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 499060
SLXbootState 54
SLXbootState never reached value 54 "SafeRUN" although SLX booted correctly.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(322)

Version 1.10.0.0:

ID: 485265
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.2.0.0 * 05/03/2020 3 MB EXE AS4_HW_X20SLX811.exe
Description V4.6 HW Upgrade (X20SLX811)

Revision information X20SLX811

Version 2.2.0.0:

ID: 674115
Safe Commissioning Options
support additional data types
ATTENTION:
- requires AR E4.71 or A4.72 and mappSafety 5.8 or higher
- at least one Safe Commissioning Option with data type BOOL must be used also
- use SafeKEY FORMAT to remove Safe CommissioningOptions with data types other than BOOL from target
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 677590
SafeDOMAIN-to-SafeDOMAIN communication
Support SafeDOMAIN-to-SafeDOMAIN communication between SafeLOGIC and SafeLOGIC-X (requires mappSafety 5.10 or higher)
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 677595
data sheet V2.05
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(580)

Version 2.1.0.4:

ID: 668575
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(570)

Version 2.1.0.3:

ID: 637415
new AR targets
support new AR targets X20CPx68x and xPC22xx
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59223_1.fw(570)

Version 2.1.0.1:

ID: 541680
major (even incompatible) changes for mapp Safety

First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted- see chapter "Switching to mapp Safety" in help!

Channel description changed: Yes
Configuration description changed: Yes
Firmwarechanged: Yes

ID: 628070
safety response time

The check of the network transmission time of cyclic data tolerated values up to 12ms higher than configured by the parameters "safe data duration"/"additional tolerated packet loss".
This could lead to an increased safety response time.

Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 644585
Setup Mode signaling
Setup Mode is now signaled with "S" and "E" LED.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59223_1.fw(570)

Version 1.10.10.3:

ID: 626170
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 637425
fix logger entry 123622
SLX didn't enter RUN state and logger number 123622 was entered when using 10 other safety modules.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.10.1:

ID: 637415
new ARtargets
support new AR targets X20CPx68x and xPC22xx
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 637425
fix logger entry 123622
SLX didn't enter RUN state and logger number 123622 was entered when using 10 other safety modules.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.10.0:

ID: 626170
safety response time
The check of the network transmission time of cyclic data tolerated values up to 12ms higher than configured by the parameters "safe data duration"/"additional tolerated packet loss".
This could lead to an increased safety response time.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59223_1.fw(330)

Version 1.10.9.0:

ID: 618245
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(330)

Version 1.10.5.0:

ID: 582825
logger message 106773
Fix for logger message 106773 "Parameter checksum sizes do not match".
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(326)

Version 1.10.4.1:

ID: 577400
Increasethe tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 598860
extended operating temperature range
Firmware preparation for hardware revisions that allow operating temperature range down to -40°C.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598875 / Support ID: 400208127
channel error when wired to +24V
Temporary channel errors (logger entry 115011) are reported if If channels are wired to +24V during module bootup.
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes

ID: 598885 / Support ID: 400208284, 400210471
logger message 110356
Logger message 110356 was generated by mistake during bootup.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598895
fix CLEAR DATA
Not all relevant data has been deleted upon command "CLEAR DATA"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598905 / Support ID:400229868, 400229876
logger entry 123432
fixed logger entry 123432 when using setup mode in combination with machineoptions
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598910 / Support ID: 400221412, 400225768
bootup time
increase of bootup time with Upgrade V1.10.2.9
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598915
increased tolerance against asynchronous communication problems
Problems in asynchronous communication to safety modulesnow cause the modules to be rated as "missing" not until the "Node Guarding Timeout" has expired (instead of after a few seconds)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 598920
additional parameters
Support additonal parameters (AsSafety FBK safeDownloadData_V2.Type=safeDATA_TYPE_ADDPARA); requiresAR >= A04.41 !
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(326)

Version 1.10.3.2:

ID: 550480 / Support ID: 400225917
Correction of SLX download frame
Correction of SLX download frame
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(324)

Version 1.10.3.1:

ID: 538795
logger message 110367 with external maschine options
SLX did not boot correctly when using external machine options with upgradeV1.10.2.9 (logger message 110367 and others).
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 538800
logger message 123416 when aknowledging a firmware mismatch
The command for firmware acknowledgement was accepted although there was still a SCAN in progress. This could lead to a failure with logger message 123416.
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: No
Firmware: 1\59223_1.fw(324)

Version 1.10.2.9:

ID: 523075
fixes for parameters in SafeDESIGNER
Minor text corrections.
Remove obsolete parameter "Cycle time".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 523080
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 523085
warn about invalid two channel processing mode
SafeDESIGNER generates a warning during compile if a two-channel evaluationchannel is used but the according parameter"Two Channel Processing Mode" is "none".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 523090
support lower "Safe Data Duration" values
Internal optimizations lead to support of lower values for "Safe Data Duration"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 523095
support Acopos P3
support all variants of Acopos P3
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 524895
Setup Mode and automated acknowledgements
- Setup Mode is supported (requires SafeDESIGNER 4.3 and AutomationRuntime B4.26 or higher)
- new parameters for automated acknowledgement of SafeKEY and firmware exchange.
Channeldescription changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 524900
Error while downloading big SafeDESIGNER applications to the SLX.
Download was aborted and the message "FileUnlock Status: Error while writing unlock status!" was shown.
Channel description changed: No
Configuration description changed: No
Firmwarechanged: Yes

ID: 528965
SafeOS Status in SafeDESIGNER Remote Control
It is a known issue that the SafeOS status in SafeDESIGNER remote control is not shown correctly when using certain versions.
SafeDESIGNER SafePLC window or AsSafety can be used instead.
This affects a set of following versions:
SLX Upgrade >=V1.10.2.x, Safety Release 1.10, SafeDESIGNER >=V4.2.3
and AR B4.26 to C4.26 or C4.33 to E4.33
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:No

ID: 529975
Update Online Help
Update Online Help V1.110
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(324)

Version 1.10.1.2:

ID: 495585
Update online help to V1.103
Update online help to V1.103
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 499055
Improve SLX cycle time
Performance optimization for improvement of internal SLXcycle time.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 499060
SLXbootState 54
SLXbootState never reached value 54 "SafeRUN" although SLX booted correctly.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59223_1.fw(322)

Version 1.10.0.0:

ID: 485265
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59223_1.fw(320)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.1.0.3 * 05/07/2019 3 MB EXE AS4_HW_X20SLX811.exe
Description V4.6 HW Upgrade (X20SLX811)

Revision information X20cSLX410

Version 2.1.0.3:

ID: 637415
new AR targets
support new AR targets X20CPx68x and xPC22xx
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\57992_1.fw(570)

Version 2.1.0.1:

ID: 541680
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 628070
safety response time
The check of the network transmission time of cyclic data tolerated values up to 12ms higher than configured by the parameters "safe data duration"/"additional tolerated packet loss".
This could lead to an increased safety response time.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 644585
Setup Mode signaling
Setup Mode is now signaled with "S" and "E" LED.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\57992_1.fw(570)

Version 1.10.10.3:

ID: 626170
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 637425
fix logger entry 123622
SLX didn't enter RUN state and logger number 123622 was entered when using 10 other safety modules.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 4\57992_1.fw(313), 5\57992_1.fw(330)

Version 1.10.10.1:

ID:637415
new AR targets
support new AR targets X20CPx68x and xPC22xx
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 637425
fix logger entry 123622
SLX didn't enter RUN state and logger number 123622 was entered when using10 other safety modules.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 4\57992_1.fw(313), 5\57992_1.fw(330)

Version 1.10.10.0:

ID: 626170
safety response time
The check of the network transmission time of cyclic data tolerated values up to 12ms higher than configured by the parameters "safe data duration"/"additional tolerated packet loss".
This could lead to an increased safety response time.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 4\57992_1.fw(313), 5\57992_1.fw(330)

Version 1.10.9.0:

ID: 618245
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 4\57992_1.fw(313), 5\57992_1.fw(330)

Version 1.10.5.0:

ID: 582825
logger message 106773
Fix for logger message 106773 "Parameter checksum sizes do not match".
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 4\57992_1.fw(313), 5\57992_1.fw(326)

Version 1.10.4.1:

ID: 585670
channel error when wired to +24V
Temporary channel errors (logger entry 115011) are reported if If channels are wired to +24V during module bootup.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 589970
additional parameters
Support additonal parameters (AsSafety FBK safeDownloadData_V2.Type=safeDATA_TYPE_ADDPARA); requires AR >= A04.41 !
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 589975
fix CLEAR DATA
Not all relevant data has been deleted upon command "CLEAR DATA"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 589980
logger entry 123432
fixed logger entry 123432 when using setup mode in combination with machineoptions
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 589985
bootup time
increase of bootup time with Upgrade V1.10.2.9
Channel description changed: No
Configuration description changed:No
Firmware changed: Yes

ID: 589990
increased tolerance against asynchronous communication problems
Problems in asynchronous communication to safety modules now cause the modules to be rated as "missing" not until the "Node Guarding Timeout" has expired(instead of after a few seconds)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 589995
extended operating temperature range
Firmware preparation for hardware revisions that allow operating temperature range down to -40°C.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 4\57992_1.fw(313), 5\57992_1.fw(326)

Version 1.10.3.2:

ID:549110 / Support ID: 400225917
Correction of SLX download frame
Correction of SLX download frame
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 4\57992_1.fw(313), 5\57992_1.fw(324)

Version 1.10.3.1:

ID: 537600
logger message 110367 with external maschine options
SLX did not bootcorrectly when using external machine options with upgrade V1.10.2.9 (logger message 110367 and others).
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 537605
logger message 123416 when aknowledging a firmware mismatch
The command for firmware acknowledgement was accepted although there was still a SCAN inprogress. This could lead to a failure with logger message 123416.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 4\57992_1.fw(313), 5\57992_1.fw(324)

Version 1.10.2.9:

ID: 381670 / Support ID: 400132230
X20(c)SLX910: warn about invalid two channel processing mode
X20(c)SLX910: SafeDESIGNER generates a warning during compile if a two-channel evaluation channel is used but the according parameter "Two Channel Processing Mode" is "none".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 481780 / Support ID: 400199480
errormessage about incompatible AR version
Error message during AutomationStudio compile when trying to use Safety Release 1.10 with an AR version that is too old.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 494085
Improve SLX cycle time
Performance optimization for improvement of internal SLX cycle time.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 494095
online help V1.103
Update online help to V1.103
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 502230
support Acopos P3 (X20SLX210 and X20SLX410 only)
X20SLX210 and X20SLX410 support all variants of Acopos P3 (X20SLX910 supports 1 axis only)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 513925 / Support ID: 400193973, 400206803
SLXbootState 54
SLXbootState never reached value 54 "SafeRUN" although SLX booted correctly.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 516045
fixes for parameters in SafeDESIGNER
Minor text corrections.
Remove obsolete parameter "Cycle time".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 521125
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 522940
Error while downloading big SafeDESIGNER applications to the SLX.
Download was aborted and the message "File Unlock Status: Error while writing unlock status!" was shown.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 522945
Setup Mode and automated acknowledgements
- Setup Mode is supported (requires SafeDESIGNER 4.3 and AutomationRuntime B4.26 or higher)
- new parameters for automated acknowledgement of SafeKEY and firmware exchange.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 528960
SafeOS Status in SafeDESIGNER Remote Control
It is a known issue that the SafeOS statusin SafeDESIGNER remote control isnot shown correctly when using certain versions.
SafeDESIGNER SafePLC window or AsSafety can be used instead.
This affects a set of following versions:
SLX Upgrade >=V1.10.2.x, Safety Release 1.10, SafeDESIGNER >=V4.2.3
and AR B4.26 to C4.26 or C4.33 to E4.33
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 4\57992_1.fw(313), 5\57992_1.fw(324)

Version 1.10.0.0:

ID: 374990 / Support ID: 400129134
SafeDESIGNER communication Variable status
Frequent activating/deactivating of SafeDESIGNER variable status could leadto failure of SLX communication.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 390095 / Support ID: 400137073
informations about actual application
CRC and timestamp of the SafeDESIGNER application that is actually stored on the SLX can be read via asynchronousdata points.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 411790
Support of release 1.10 including openSAFETY 1.5
Support of release 1.10 includingopenSAFETY 1.5 with easier parametrizationof timing parameters
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 426855 / Support ID: 400151377
Optional modules no longer reported missing via SLX LEDs
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 440400 / Support ID: 400147709, 400160605, 400165854, 400175456
Input checksum data error
In rare cases it could happen sporadically thatthe SLX entered failsafe state with "Input checksum data error" (logger messages 69648, 73744, 69655 und 73751)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 448715
application download
Performance optimization of application download to SLX.
Some sequences have been changes for this which omitted some of the values ofSLXbootState.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 448980 / Support ID: 400162839, 400168358
limit of max 1 SLX per CPU / line integration
If there are more then one SLX in the AS hardware tree, only one of them may be enabled.
On the other hand now it is allowed to downloada SafeDESIGNER application that doesn't match the SafeLOGIC-ID of the AS hardware tree.
Channel description changed: No
Configuration descriptionchanged: Yes
Firmware changed: Yes
Firmware: 4\57992_1.fw(313), 5\57992_1.fw(320)

Version 1.9.2.0:

ID: 450785 / Support ID: 400137924
SafeLOGIC-X with Panal PC
SafeLOGIC-X didn't work with some Panal PCs (e.g. 5PC901 and 5PPC2100)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 4\57992_1.fw(313)

Version 1.9.1.0:

ID: 425385
change of input filter
The behaviour of the input filter has changed.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 425390
Update Online Help
Update Online Help V1.91
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: No

ID: 425395
fw valid from SafetyRelease 1.8 on
The firmware is used for all SafetyReleases from 1.8on.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 425400
Default values changed
Default values of Cycle_Time_typical_us and Default_Max_X2X_CycleTime_us changed
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 4\57992_1.fw(313)

Version 1.9.0.0:

ID: 419950
The module also supports SafetyRelease 1.9
Starting with this version, the module also supports SafetyRelease 1.9
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 419955
Update Online Help
Update Online Help V1.90
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 2\57992_1.fw(311)

Version 1.8.0.3:

ID: 393855
first officialrelease
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 2\57992_1.fw(311)