2.11.0.0 * 31/01/2020 2 Mo EXE AS3.0_HW_X20BC8084.exe
Description V3.0 HW Upgrade (X20BC8084)

Revision information X20BC8084

Version 2.11.0.0:

ID: 664370
DNA: Hub of PLK BC active until first IDENT_REQUEST
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 664375
Adaptationsfor Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 665750
ModuleOk of IO module FALSE after warm restart even though the module is working as expected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 665835
Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 666195
Module documentation revised
Data sheet V2.38
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9844_1.fw(430), 1\9844_2.fw(430), 1\9844_3.fw(430), 1\9844_4.fw(430), 1\9844_5.fw(430), 1\9844_6.fw(430), 1\9844_7.fw(430)

Version 2.10.0.0:

ID: 647935
Optimization of the firmware update process
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(428), 1\9844_2.fw(428), 1\9844_3.fw(428), 1\9844_4.fw(428), 1\9844_5.fw(428), 1\9844_6.fw(428), 1\9844_7.fw(428)

Version 2.9.0.0:

ID: 624085
Optimization of hub behavior
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629010
Ring redundancy: Cannot address the CN that closes the ring
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629075
DNA: BC as head-end station switching hub off again
Channel description changed: No
Configuration description changed:No
Firmware changed: Yes

ID: 629160
Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(427), 1\9844_2.fw(427), 1\9844_3.fw(427), 1\9844_4.fw(427), 1\9844_5.fw(427), 1\9844_6.fw(427)

Version 2.8.0.0:

ID: 619145 / Support ID: 400257683
DNA: PLK hub forwarding for the next node not enabled in rare cases
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 619180 / Support ID: 400262159
Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(426), 1\9844_2.fw(426), 1\9844_3.fw(426), 1\9844_4.fw(426), 1\9844_5.fw(426), 1\9844_6.fw(426)

Version 2.7.0.0:

ID: 586760 / Support ID: 400241376
Temporary toggling of data point ModuleOk if I/O module fails
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(424), 1\9844_2.fw(424), 1\9844_3.fw(424), 1\9844_4.fw(424), 1\9844_5.fw(424), 1\9844_6.fw(424)

Version 2.6.0.0:

ID: 574935
Optimization of boot procedure for hardware variant 5 und 6
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(423), 1\9844_2.fw(423), 1\9844_3.fw(423), 1\9844_4.fw(423), 1\9844_5.fw(423), 1\9844_6.fw(423)

Version 2.5.6.0:

ID: 565090
Optimization the boot up for hardware variant 5
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(422), 1\9844_2.fw(422), 1\9844_3.fw(422), 1\9844_4.fw(422), 1\9844_5.fw(422)

Version 2.5.5.0:

ID: 551120
Startup time optimizations
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes
Firmware: 1\9844_1.fw(421), 1\9844_2.fw(421), 1\9844_3.fw(421), 1\9844_4.fw(421), 1\9844_5.fw(421)

Version 2.5.4.0:

ID: 540315 / Support ID: 400202320
BC sporadically not going into Operational due to X2X-bus problems at startup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(419), 1\9844_2.fw(419), 1\9844_3.fw(419), 1\9844_4.fw(419)

Version 2.5.3.0:

ID: 523470 / Support ID: 400205694
safety modules not switching to operational state
SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(417), 1\9844_2.fw(417), 1\9844_3.fw(417), 1\9844_4.fw(417)

Version 2.5.2.0:

ID: 493885 / Support ID: 400103115, 400101850, 400154063, 400190752
First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(415), 1\9844_2.fw(415), 1\9844_3.fw(415), 1\9844_4.fw(415)

Version 2.5.0.0:

ID: 468060 / Support ID: 400178654
Safetymodules in connection with PLK BCs, with only input datapoints, are not initialized.by SL
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468065
optimization of X2X FW updates
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468070 / SupportID: 400177243
X2X FW update of several X2X modules is not working
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468530
CiR support
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\9844_1.fw(413), 1\9844_2.fw(413), 1\9844_3.fw(413)

Version 2.3.0.0:

ID: 454760
AS, System Designer support:cable redundancy
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 460105 / Support ID: 400168329
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 460225 / Support ID: 400150525
Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 466675
Module documentation revised
Data sheet V 2.32
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: No
Firmware: 1\9844_1.fw(411), 1\9844_2.fw(411), 1\9844_3.fw(411)

Version 2.2.1.0:

ID: 449590
Error when running X20BC8084 (Rev. < G0) in base module X20BB80
Correction with new firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(401), 1\9844_2.fw(401), 1\9844_3.fw(401)

Version 2.2.0.0:

ID: 439100 / Support ID: 400150496
I/O modules behind POWERLINK bus controllersno longer achieving Operationalmode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 439205 / Support ID: 400128436
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode aftermultiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(400), 1\9844_2.fw(400), 1\9844_3.fw(400)

Version 2.1.0.0:

ID: 404490
X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed.
When empty backplanes are plugged or unpluggedon the end of the X2XLink thediagnostic data point "StationAtBusEnd" die notchange.
The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(300), 1\9844_2.fw(300), 1\9844_3.fw(300)

Version 2.0.0.0:

ID: 390280 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(210), 1\9844_2.fw(210), 1\9844_3.fw(210)

Version 1.3.7.0:

ID: 376980
With specialconstructions it could be that stations will be lost.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(174), 1\9844_2.fw(174), 1\9844_3.fw(174)

Version 1.3.6.0:

ID: 326655
Link-Selektor funktion upgraded
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(169), 1\9844_2.fw(169),1\9844_3.fw(169)

Version 1.3.5.0:

ID: 310790 / Support ID: 400097674
POWERLINK V1: Bug-fix for Up/Downgrade
POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 311025 / Support ID: 400051206
Expansion: Link- selector flag
New datapoints:&lt;br/&gt;- RedundancyFirstLinkState&lt;br/&gt;- RedundancySecondLinkState
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\9844_1.fw(168), 1\9844_2.fw(168), 1\9844_3.fw(168)

Version 1.3.4.0:

ID: 305155 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(167), 1\9844_2.fw(167), 1\9844_3.fw(167)

Version 1.3.3.0:

ID: 298990 / Support ID: 400090781
Problem with FW-Update of IO modules on Powerlink buscontrollers
The firmware update of IO modules does not work in certain configurations.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(165), 1\9844_2.fw(165), 1\9844_3.fw(165)

Version 1.3.2.0:

ID: 289020
Certain X2X configurations don't work
In very rare I/O constellations, the X2X modules don't start
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 291455
Upgrade 1.3.1.0 on X20BC8084 to revision E0 may cause problems
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(164), 1\9844_2.fw(164), 1\9844_3.fw(164)

Version 1.3.0.0:

ID: 271200
Upgraded Kabelredundanz
support Hardwarevariant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277180
Support of 'Multiple AsynchronousSend'
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277750
New X2X datapoints
- NettimeOffsetX2X and NettimeX2X
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\9844_1.fw(160), 1\9844_2.fw(160), 1\9844_3.fw(160)

Version 1.2.1.0:

ID: 271200
Upgraded Kabelredundanz
support Hardwarevariant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(154), 1\9844_2.fw(154)

Version 1.2.0.0:

ID: 265540
Optimation of Kabelredundancy (Link Selector) ; Update behavior on X2X bus improved
- optimation of Kabelredundancy (Link Selector)
- faster updating of modules with big FW files on the X2X bus of the BC
- new objects: 20A3h, 2000h/9 and20F0h/31
Channel description changed: Yes
Configuration descriptionchanged: Yes
Firmware changed: Yes
Firmware: 1\9844_2.fw(146)

Version 1.0.9.0:

ID: 220450
Extensions and Bugfixes
- Combination of PollResponse-Chaining and PollRequest-Synchronization did not workcorrectly (A&P 218765)
- Network-Failure-Detection did not work when BC_RedundancyTxMode_U8 = 1
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_2.fw(146)

Version 1.0.8.0:

ID: 218545
Extensions and Bugfixes
- Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1
- Support of PollResponse-Chaining
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(145)

Version 1.0.4.0:

ID: 183390
New info-/diagnostic data points, new FW 1.39 for signal filter and corrections
New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9844_1.fw(141)

Version 1.0.3.0:

ID: 173290
First version of the buscontroller with cable redundancy
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:No
Firmware: 1\9844_1.fw(138)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.10.0.0 * 10/07/2019 2 Mo EXE AS3.0_HW_X20BC8084.exe
Description V3.0 HW Upgrade (X20BC8084)

Revision information X20BC8084

Version 2.10.0.0:

ID: 647935
Optimization of the firmware update process
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(428), 1\9844_2.fw(428), 1\9844_3.fw(428), 1\9844_4.fw(428), 1\9844_5.fw(428), 1\9844_6.fw(428),1\9844_7.fw(428)

Version 2.9.0.0:

ID: 624085
Optimization of hub behavior
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629010
Ring redundancy: Cannot address the CN that closes the ring
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes

ID: 629075
DNA: BC as head-end station switching hub off again
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629160
Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(427), 1\9844_2.fw(427), 1\9844_3.fw(427), 1\9844_4.fw(427), 1\9844_5.fw(427), 1\9844_6.fw(427)

Version 2.8.0.0:

ID: 619145 / Support ID: 400257683
DNA: PLK hub forwarding for the next node not enabled in rare cases
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 619180 / Support ID: 400262159
Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(426), 1\9844_2.fw(426), 1\9844_3.fw(426), 1\9844_4.fw(426), 1\9844_5.fw(426), 1\9844_6.fw(426)

Version 2.7.0.0:

ID: 586760 / Support ID: 400241376
Temporary toggling ofdata point ModuleOk if I/O module fails
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(424), 1\9844_2.fw(424), 1\9844_3.fw(424), 1\9844_4.fw(424),1\9844_5.fw(424), 1\9844_6.fw(424)

Version 2.6.0.0:

ID: 574935
Optimization of boot procedure for hardware variant 5 und 6
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(423), 1\9844_2.fw(423), 1\9844_3.fw(423), 1\9844_4.fw(423), 1\9844_5.fw(423), 1\9844_6.fw(423)

Version 2.5.6.0:

ID: 565090
Optimization the boot up for hardware variant5
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(422), 1\9844_2.fw(422), 1\9844_3.fw(422), 1\9844_4.fw(422), 1\9844_5.fw(422)

Version 2.5.5.0:

ID: 551120
Startup time optimizations
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(421), 1\9844_2.fw(421), 1\9844_3.fw(421), 1\9844_4.fw(421), 1\9844_5.fw(421)

Version 2.5.4.0:

ID: 540315 /Support ID: 400202320
BC sporadically not going into Operational due to X2X-bus problems at startup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(419), 1\9844_2.fw(419), 1\9844_3.fw(419), 1\9844_4.fw(419)

Version 2.5.3.0:

ID: 523470 / Support ID: 400205694
safety modules notswitching to operational state
SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(417), 1\9844_2.fw(417), 1\9844_3.fw(417), 1\9844_4.fw(417)

Version 2.5.2.0:

ID: 493885 / Support ID:400103115, 400101850, 400154063, 400190752
First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(415), 1\9844_2.fw(415), 1\9844_3.fw(415), 1\9844_4.fw(415)

Version 2.5.0.0:

ID: 468060 / Support ID: 400178654
Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468065
optimization of X2X FW updates
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468070 / Support ID: 400177243
X2X FW update of several X2X modules is not working
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468530
CiR support
Channel description changed: No
Configuration description changed: Yes
Firmwarechanged: No
Firmware: 1\9844_1.fw(413), 1\9844_2.fw(413), 1\9844_3.fw(413)

Version 2.3.0.0:

ID: 454760
AS, System Designer support: cable redundancy
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 460105 / Support ID: 400168329
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes

ID: 460225 / Support ID: 400150525
Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC
Channel description changed: No
Configuration description changed: No
Firmwarechanged: Yes

ID: 466675
Module documentation revised
Data sheet V 2.32
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9844_1.fw(411), 1\9844_2.fw(411), 1\9844_3.fw(411)

Version 2.2.1.0:

ID: 449590
Error when running X20BC8084 (Rev. < G0) in base module X20BB80
Correction with new firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(401), 1\9844_2.fw(401), 1\9844_3.fw(401)

Version 2.2.0.0:

ID: 439100 / Support ID: 400150496
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 439205 / Support ID: 400128436
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(400), 1\9844_2.fw(400), 1\9844_3.fw(400)

Version 2.1.0.0:

ID: 404490
X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed.
When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change.
The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(300), 1\9844_2.fw(300), 1\9844_3.fw(300)

Version 2.0.0.0:

ID: 390280 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(210), 1\9844_2.fw(210), 1\9844_3.fw(210)

Version 1.3.7.0:

ID: 376980
With special constructions it could be that stations will be lost.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(174), 1\9844_2.fw(174), 1\9844_3.fw(174)

Version 1.3.6.0:

ID: 326655
Link-Selektor funktion upgraded
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(169), 1\9844_2.fw(169), 1\9844_3.fw(169)

Version 1.3.5.0:

ID: 310790 / Support ID: 400097674
POWERLINK V1: Bug-fix for Up/Downgrade
POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 311025 / Support ID: 400051206
Expansion: Link- selector flag
New datapoints:&lt;br/&gt;- RedundancyFirstLinkState&lt;br/&gt;- RedundancySecondLinkState
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\9844_1.fw(168), 1\9844_2.fw(168), 1\9844_3.fw(168)

Version 1.3.4.0:

ID: 305155 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a highload on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronouscommunication caused the safety-IO to stop.
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(167), 1\9844_2.fw(167), 1\9844_3.fw(167)

Version1.3.3.0:

ID: 298990 / Support ID: 400090781
Problem with FW-Update of IO modules on Powerlink buscontrollers
The firmware update of IO modules does not work in certain configurations.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(165), 1\9844_2.fw(165), 1\9844_3.fw(165)

Version 1.3.2.0:

ID: 289020
Certain X2X configurations don't work
In very rare I/O constellations, the X2X modules don't start
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 291455
Upgrade 1.3.1.0 on X20BC8084 to revision E0 may cause problems
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(164), 1\9844_2.fw(164), 1\9844_3.fw(164)

Version 1.3.0.0:

ID: 271200
Upgraded Kabelredundanz
support Hardwarevariant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277180
Support of 'Multiple Asynchronous Send'
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277750
New X2X datapoints
- NettimeOffsetX2X and NettimeX2X
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\9844_1.fw(160), 1\9844_2.fw(160), 1\9844_3.fw(160)

Version1.2.1.0:

ID: 271200
Upgraded Kabelredundanz
support Hardwarevariant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(154), 1\9844_2.fw(154)

Version 1.2.0.0:

ID: 265540
Optimation of Kabelredundancy (Link Selector) ; Update behavior on X2X bus improved
- optimation of Kabelredundancy (Link Selector)
- faster updating of modules with big FW files on the X2X bus of the BC
- new objects: 20A3h, 2000h/9 and 20F0h/31
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\9844_2.fw(146)

Version 1.0.9.0:

ID: 220450
Extensions and Bugfixes
- Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765)
- Network-Failure-Detection did not work when BC_RedundancyTxMode_U8 = 1
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_2.fw(146)

Version 1.0.8.0:

ID: 218545
Extensions and Bugfixes
- Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1
- Support of PollResponse-Chaining
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(145)

Version 1.0.4.0:

ID: 183390
New info-/diagnostic data points, new FW 1.39 for signal filter and corrections
New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9844_1.fw(141)

Version 1.0.3.0:

ID: 173290
First version of the buscontroller with cable redundancy
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9844_1.fw(138)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.9.0.0 * 01/03/2019 2 Mo EXE AS3.0_HW_X20BC8084.exe
Description V3.0 HW Upgrade (X20BC8084)

Revision information X20BC8084

Version 2.9.0.0:

ID: 624085
Optimization of hub behavior
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629010
Ring redundancy: Cannot address theCN that closes the ring
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629075
DNA: BC as head-end station switching hub off again
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629160
Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(427), 1\9844_2.fw(427), 1\9844_3.fw(427), 1\9844_4.fw(427), 1\9844_5.fw(427), 1\9844_6.fw(427)

Version 2.8.0.0:

ID: 619145 / Support ID: 400257683
DNA: PLK hub forwarding for the next node not enabled in rare cases
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes

ID: 619180 / Support ID: 400262159
Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(426), 1\9844_2.fw(426), 1\9844_3.fw(426), 1\9844_4.fw(426), 1\9844_5.fw(426), 1\9844_6.fw(426)

Version 2.7.0.0:

ID: 586760 /Support ID: 400241376
Temporary toggling of data point ModuleOk if I/O module fails
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(424), 1\9844_2.fw(424), 1\9844_3.fw(424), 1\9844_4.fw(424), 1\9844_5.fw(424), 1\9844_6.fw(424)

Version 2.6.0.0:

ID: 574935
Optimization of boot procedure for hardware variant 5 und 6
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(423), 1\9844_2.fw(423), 1\9844_3.fw(423), 1\9844_4.fw(423), 1\9844_5.fw(423), 1\9844_6.fw(423)

Version 2.5.6.0:

ID: 565090
Optimization the boot up for hardware variant 5
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(422), 1\9844_2.fw(422), 1\9844_3.fw(422), 1\9844_4.fw(422), 1\9844_5.fw(422)

Version 2.5.5.0:

ID: 551120
Startup time optimizations
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(421), 1\9844_2.fw(421), 1\9844_3.fw(421), 1\9844_4.fw(421), 1\9844_5.fw(421)

Version 2.5.4.0:

ID: 540315 / Support ID: 400202320
BC sporadically not going into Operational due to X2X-bus problems at startup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(419), 1\9844_2.fw(419),1\9844_3.fw(419), 1\9844_4.fw(419)

Version 2.5.3.0:

ID: 523470 / Support ID: 400205694
safety modules not switching to operational state
SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(417), 1\9844_2.fw(417), 1\9844_3.fw(417), 1\9844_4.fw(417)

Version 2.5.2.0:

ID: 493885 / Support ID: 400103115, 400101850, 400154063, 400190752
First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(415), 1\9844_2.fw(415), 1\9844_3.fw(415), 1\9844_4.fw(415)

Version 2.5.0.0:

ID: 468060 / Support ID: 400178654
Safety modules in connection withPLK BCs, with only input datapoints, are not initialized.by SL
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468065
optimization of X2X FW updates
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468070 / Support ID: 400177243
X2X FW update of several X2X modules is not working
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes

ID: 468530
CiR support
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\9844_1.fw(413), 1\9844_2.fw(413), 1\9844_3.fw(413)

Version 2.3.0.0:

ID: 454760
AS, System Designer support: cable redundancy
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 460105 / Support ID: 400168329
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 460225 / Support ID: 400150525
Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 466675
Module documentation revised
Data sheet V 2.32
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9844_1.fw(411), 1\9844_2.fw(411), 1\9844_3.fw(411)

Version 2.2.1.0:

ID: 449590
Error when running X20BC8084 (Rev. < G0) in base module X20BB80
Correction with new firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(401), 1\9844_2.fw(401), 1\9844_3.fw(401)

Version 2.2.0.0:

ID: 439100 / Support ID: 400150496
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 439205 / Support ID: 400128436
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(400), 1\9844_2.fw(400),1\9844_3.fw(400)

Version 2.1.0.0:

ID: 404490
X2XLink-BC:StationAtBusEnd does not change, when empty backplanes are addedor removed.
When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change.
The data pointdie change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is suppliedwith power, but the supply for the IO is missing.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(300), 1\9844_2.fw(300), 1\9844_3.fw(300)

Version 2.0.0.0:

ID: 390280 / Support ID: 400129274
Uncommon X2Xsettings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(210), 1\9844_2.fw(210), 1\9844_3.fw(210)

Version 1.3.7.0:

ID: 376980
With special constructions it could be that stations will be lost.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(174), 1\9844_2.fw(174), 1\9844_3.fw(174)

Version 1.3.6.0:

ID: 326655
Link-Selektor funktion upgraded
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(169), 1\9844_2.fw(169), 1\9844_3.fw(169)

Version 1.3.5.0:

ID: 310790 / Support ID: 400097674
POWERLINK V1: Bug-fix for Up/Downgrade
POWERLINK V1 FW upgrade problem could be accoredafter PowerOn beginning with HW- Upgrade Version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 311025 / Support ID: 400051206
Expansion: Link- selector flag
New datapoints:&lt;br/&gt;- RedundancyFirstLinkState&lt;br/&gt;- RedundancySecondLinkState
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\9844_1.fw(168), 1\9844_2.fw(168), 1\9844_3.fw(168)

Version 1.3.4.0:

ID: 305155 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(167), 1\9844_2.fw(167), 1\9844_3.fw(167)

Version 1.3.3.0:

ID: 298990/ Support ID: 400090781
Problem with FW-Update of IO modules on Powerlink buscontrollers
The firmware update of IO modules does not work in certain configurations.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(165), 1\9844_2.fw(165), 1\9844_3.fw(165)

Version 1.3.2.0:

ID: 289020
Certain X2X configurations don't work
In very rare I/O constellations, the X2X modules don't start
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 291455
Upgrade 1.3.1.0 on X20BC8084 to revision E0 may cause problems
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(164), 1\9844_2.fw(164), 1\9844_3.fw(164)

Version 1.3.0.0:

ID: 271200
Upgraded Kabelredundanz
support Hardwarevariant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277180
Support of 'Multiple Asynchronous Send'
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277750
New X2X datapoints
- NettimeOffsetX2X and NettimeX2X
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\9844_1.fw(160), 1\9844_2.fw(160), 1\9844_3.fw(160)

Version 1.2.1.0:

ID: 271200
Upgraded Kabelredundanz
support Hardwarevariant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(154), 1\9844_2.fw(154)

Version 1.2.0.0:

ID: 265540
Optimation of Kabelredundancy (Link Selector); Update behavior on X2X bus improved
- optimation of Kabelredundancy (Link Selector)
- faster updating of modules with big FW files on the X2X bus of the BC
- new objects: 20A3h, 2000h/9 and 20F0h/31
Channel description changed: Yes
Configuration description changed: Yes
Firmwarechanged: Yes
Firmware: 1\9844_2.fw(146)

Version 1.0.9.0:

ID: 220450
Extensions and Bugfixes
- Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765)
- Network-Failure-Detection did not work when BC_RedundancyTxMode_U8 = 1
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_2.fw(146)

Version 1.0.8.0:

ID: 218545
Extensions and Bugfixes
- Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1
- Support of PollResponse-Chaining
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(145)

Version 1.0.4.0:

ID: 183390
New info-/diagnostic data points, new FW 1.39 for signal filter and corrections
New info-/diagnostic data points in HWC, new FW 1.39 for signal filterand corrections
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9844_1.fw(141)

Version 1.0.3.0:

ID: 173290
First version of the buscontroller with cable redundancy
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9844_1.fw(138)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.8.0.0 * 05/12/2018 2 Mo EXE AS3.0_HW_X20BC8084.exe
Description V3.0 HW Upgrade (X20BC8084)

Revision information X20BC8084

Version 2.8.0.0:

ID: 619145 / Support ID: 400257683
DNA: PLK hub forwarding for the next node not enabled in rare cases
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 619180 / Support ID: 400262159
Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(426), 1\9844_2.fw(426), 1\9844_3.fw(426), 1\9844_4.fw(426), 1\9844_5.fw(426), 1\9844_6.fw(426)

Version 2.7.0.0:

ID: 586760 / Support ID: 400241376
Temporarytoggling of data point ModuleOk if I/O module fails
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(424), 1\9844_2.fw(424), 1\9844_3.fw(424), 1\9844_4.fw(424), 1\9844_5.fw(424), 1\9844_6.fw(424)

Version 2.6.0.0:

ID: 574935
Optimization of boot procedure for hardware variant 5 und 6
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(423), 1\9844_2.fw(423), 1\9844_3.fw(423), 1\9844_4.fw(423), 1\9844_5.fw(423), 1\9844_6.fw(423)

Version 2.5.6.0:

ID: 565090
Optimization the boot up for hardware variant 5
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(422), 1\9844_2.fw(422), 1\9844_3.fw(422), 1\9844_4.fw(422), 1\9844_5.fw(422)

Version 2.5.5.0:

ID: 551120
Startup time optimizations
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(421), 1\9844_2.fw(421), 1\9844_3.fw(421), 1\9844_4.fw(421), 1\9844_5.fw(421)

Version 2.5.4.0:

ID: 540315 / Support ID: 400202320
BC sporadically not going into Operational due to X2X-bus problems at startup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(419), 1\9844_2.fw(419), 1\9844_3.fw(419), 1\9844_4.fw(419)

Version 2.5.3.0:

ID: 523470 / Support ID: 400205694
safetymodules not switching to operational state
SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(417), 1\9844_2.fw(417), 1\9844_3.fw(417), 1\9844_4.fw(417)

Version 2.5.2.0:

ID: 493885 /Support ID: 400103115, 400101850, 400154063, 400190752
First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s.
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes
Firmware: 1\9844_1.fw(415), 1\9844_2.fw(415), 1\9844_3.fw(415), 1\9844_4.fw(415)

Version 2.5.0.0:

ID: 468060 / Support ID: 400178654
Safety modules in connection with PLK BCs, with only input datapoints,are not initialized.by SL
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468065
optimization of X2X FW updates
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468070 / Support ID: 400177243
X2X FW update of several X2X modules is not working
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468530
CiR support
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\9844_1.fw(413), 1\9844_2.fw(413), 1\9844_3.fw(413)

Version 2.3.0.0:

ID: 454760
AS, System Designer support: cable redundancy
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 460105 / Support ID: 400168329
I/O modules behind POWERLINK bus controllers nolonger achieving Operationalmode after multiple power-on cycles
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 460225 / Support ID: 400150525
Error 114834"Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLXhinter BC
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 466675
Module documentation revised
Data sheet V 2.32
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9844_1.fw(411), 1\9844_2.fw(411), 1\9844_3.fw(411)

Version 2.2.1.0:

ID: 449590
Error when running X20BC8084 (Rev. < G0) in base module X20BB80
Correction with new firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(401), 1\9844_2.fw(401), 1\9844_3.fw(401)

Version 2.2.0.0:

ID: 439100 / Support ID: 400150496
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 439205 / Support ID: 400128436
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(400), 1\9844_2.fw(400), 1\9844_3.fw(400)

Version 2.1.0.0:

ID: 404490
X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed.
When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change.
The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(300), 1\9844_2.fw(300), 1\9844_3.fw(300)

Version 2.0.0.0:

ID: 390280 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of buscontroller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(210), 1\9844_2.fw(210), 1\9844_3.fw(210)

Version 1.3.7.0:

ID: 376980
With special constructions it could be that stations will be lost.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(174), 1\9844_2.fw(174), 1\9844_3.fw(174)

Version 1.3.6.0:

ID: 326655
Link-Selektor funktion upgraded
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(169), 1\9844_2.fw(169), 1\9844_3.fw(169)

Version 1.3.5.0:

ID: 310790 / Support ID: 400097674
POWERLINK V1: Bug-fix for Up/Downgrade
POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 311025 / Support ID: 400051206
Expansion: Link- selector flag
New datapoints:&lt;br/&gt;- RedundancyFirstLinkState&lt;br/&gt;- RedundancySecondLinkState
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\9844_1.fw(168), 1\9844_2.fw(168), 1\9844_3.fw(168)

Version 1.3.4.0:

ID: 305155 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(167), 1\9844_2.fw(167), 1\9844_3.fw(167)

Version 1.3.3.0:

ID: 298990 / Support ID: 400090781
Problemwith FW-Update of IO modules on Powerlink buscontrollers
The firmware update of IO modules does not work in certain configurations.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(165), 1\9844_2.fw(165), 1\9844_3.fw(165)

Version 1.3.2.0:

ID: 289020
Certain X2X configurations don't work
In very rare I/O constellations, the X2X modules don't start
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 291455
Upgrade 1.3.1.0 on X20BC8084 to revision E0 may cause problems
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(164), 1\9844_2.fw(164), 1\9844_3.fw(164)

Version 1.3.0.0:

ID: 271200
Upgraded Kabelredundanz
support Hardwarevariant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277180
Support of 'Multiple Asynchronous Send'
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277750
NewX2X datapoints
- NettimeOffsetX2X and NettimeX2X
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\9844_1.fw(160), 1\9844_2.fw(160), 1\9844_3.fw(160)

Version 1.2.1.0:

ID: 271200
Upgraded Kabelredundanz
support Hardwarevariant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(154), 1\9844_2.fw(154)

Version 1.2.0.0:

ID: 265540
Optimation of Kabelredundancy (Link Selector) ; Update behavior on X2X bus improved
- optimation of Kabelredundancy (Link Selector)
- faster updating of modules with big FW files on the X2X bus of the BC
- new objects: 20A3h, 2000h/9 and 20F0h/31
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\9844_2.fw(146)

Version 1.0.9.0:

ID: 220450
Extensions and Bugfixes
- Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765)
- Network-Failure-Detection did notwork when BC_RedundancyTxMode_U8 = 1
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_2.fw(146)

Version 1.0.8.0:

ID: 218545
Extensions and Bugfixes
- Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1
- Support of PollResponse-Chaining
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(145)

Version 1.0.4.0:

ID: 183390
New info-/diagnostic data points, new FW 1.39 for signal filter and corrections
New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9844_1.fw(141)

Version 1.0.3.0:

ID: 173290
First version of the buscontroller with cable redundancy
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9844_1.fw(138)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.7.0.0 * 17/04/2018 2 Mo EXE AS3.0_HW_X20BC8084.exe
Description V3.0 HW Upgrade (X20BC8084)

Revision information X20BC8084

Version 2.7.0.0:

ID: 586760 / Support ID: 400241376
Temporary toggling of data point ModuleOk if I/O module fails
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(424), 1\9844_2.fw(424), 1\9844_3.fw(424), 1\9844_4.fw(424), 1\9844_5.fw(424), 1\9844_6.fw(424)

Version 2.6.0.0:

ID: 574935
Optimization of boot procedure for hardware variant 5 und 6
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(423), 1\9844_2.fw(423), 1\9844_3.fw(423), 1\9844_4.fw(423), 1\9844_5.fw(423), 1\9844_6.fw(423)

Version 2.5.6.0:

ID: 565090
Optimization the boot up for hardware variant 5
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(422), 1\9844_2.fw(422), 1\9844_3.fw(422), 1\9844_4.fw(422), 1\9844_5.fw(422)

Version 2.5.5.0:

ID: 551120
Startup time optimizations
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(421), 1\9844_2.fw(421), 1\9844_3.fw(421), 1\9844_4.fw(421), 1\9844_5.fw(421)

Version 2.5.4.0:

ID: 540315 / Support ID: 400202320
BC sporadically not going into Operational due to X2X-bus problems at startup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(419), 1\9844_2.fw(419), 1\9844_3.fw(419), 1\9844_4.fw(419)

Version 2.5.3.0:

ID: 523470 / Support ID: 400205694
safety modules not switching to operational state
SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(417), 1\9844_2.fw(417), 1\9844_3.fw(417), 1\9844_4.fw(417)

Version 2.5.2.0:

ID: 493885 / Support ID: 400103115, 400101850, 400154063, 400190752
First POWERLINK UDP ASndSDO transfert after long time takes up to 5s.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(415), 1\9844_2.fw(415), 1\9844_3.fw(415), 1\9844_4.fw(415)

Version 2.5.0.0:

ID: 468060 / Support ID: 400178654
Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468065
optimization of X2X FW updates
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468070 / Support ID: 400177243
X2X FW update of several X2X modules is not working
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468530
CiR support
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\9844_1.fw(413), 1\9844_2.fw(413), 1\9844_3.fw(413)

Version 2.3.0.0:

ID: 454760
AS, System Designer support: cable redundancy
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 460105 / Support ID: 400168329
I/O modules behind POWERLINK bus controllers no longerachieving Operationalmode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 460225 / Support ID: 400150525
Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 466675
Module documentation revised
Data sheet V 2.32
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9844_1.fw(411),1\9844_2.fw(411), 1\9844_3.fw(411)

Version 2.2.1.0:

ID: 449590
Error when running X20BC8084 (Rev. < G0) in base module X20BB80
Correction with new firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(401), 1\9844_2.fw(401), 1\9844_3.fw(401)

Version 2.2.0.0:

ID: 439100 / Support ID: 400150496
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 439205 / Support ID: 400128436
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(400), 1\9844_2.fw(400), 1\9844_3.fw(400)

Version 2.1.0.0:

ID: 404490
X2XLink-BC: StationAtBusEnd does not change, when emptybackplanes are addedor removed.
When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change.
The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implementedto update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(300), 1\9844_2.fw(300), 1\9844_3.fw(300)

Version 2.0.0.0:

ID: 390280 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(210), 1\9844_2.fw(210), 1\9844_3.fw(210)

Version 1.3.7.0:

ID: 376980
With special constructions it could be that stations will be lost.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(174), 1\9844_2.fw(174), 1\9844_3.fw(174)

Version 1.3.6.0:

ID: 326655
Link-Selektor funktion upgraded
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(169), 1\9844_2.fw(169), 1\9844_3.fw(169)

Version 1.3.5.0:

ID: 310790 / SupportID: 400097674
POWERLINK V1: Bug-fix for Up/Downgrade
POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 311025 / Support ID: 400051206
Expansion: Link- selector flag
New datapoints:&lt;br/&gt;- RedundancyFirstLinkState&lt;br/&gt;- RedundancySecondLinkState
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\9844_1.fw(168), 1\9844_2.fw(168), 1\9844_3.fw(168)

Version 1.3.4.0:

ID: 305155 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was ahigh load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(167), 1\9844_2.fw(167), 1\9844_3.fw(167)

Version 1.3.3.0:

ID: 298990 / Support ID: 400090781
Problem with FW-Update of IO modules on Powerlink buscontrollers
The firmware update ofIO modules does not work in certain configurations.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(165), 1\9844_2.fw(165), 1\9844_3.fw(165)

Version 1.3.2.0:

ID: 289020
Certain X2X configurations don't work
In very rare I/O constellations, the X2X modules don't start
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 291455
Upgrade 1.3.1.0 on X20BC8084 to revision E0 may cause problems
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(164), 1\9844_2.fw(164), 1\9844_3.fw(164)

Version 1.3.0.0:

ID: 271200
Upgraded Kabelredundanz
support Hardwarevariant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277180
Support of 'Multiple Asynchronous Send'
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277750
New X2X datapoints
- NettimeOffsetX2X and NettimeX2X
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\9844_1.fw(160), 1\9844_2.fw(160), 1\9844_3.fw(160)

Version 1.2.1.0:

ID: 271200
Upgraded Kabelredundanz
support Hardwarevariant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(154),1\9844_2.fw(154)

Version 1.2.0.0:

ID: 265540
Optimation of Kabelredundancy (Link Selector) ; Update behavior on X2X bus improved
- optimation of Kabelredundancy (Link Selector)
- faster updating of modules with big FW files on the X2X bus of the BC
- new objects: 20A3h, 2000h/9 and 20F0h/31
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\9844_2.fw(146)

Version 1.0.9.0:

ID: 220450
Extensions and Bugfixes
- Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765)
- Network-Failure-Detection did not work when BC_RedundancyTxMode_U8 = 1
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_2.fw(146)

Version 1.0.8.0:

ID: 218545
Extensions and Bugfixes
- Firmware-Version is transferred via IdentResponse in the first4 bytes of the field VendorSpecificExt1
- Support of PollResponse-Chaining
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(145)

Version1.0.4.0:

ID: 183390
New info-/diagnostic data points, new FW 1.39 for signal filter and corrections
New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9844_1.fw(141)

Version 1.0.3.0:

ID: 173290
First version of the buscontroller with cable redundancy
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9844_1.fw(138)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.6.0.0 * 02/02/2018 2 Mo EXE AS3.0_HW_X20BC8084.exe
Description V3.0 HW Upgrade (X20BC8084)

Revision information X20BC8084

Version 2.6.0.0:

ID: 574935
Optimization of boot procedure for hardware variant 5 und 6
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(423), 1\9844_2.fw(423), 1\9844_3.fw(423), 1\9844_4.fw(423), 1\9844_5.fw(423), 1\9844_6.fw(423)

Version 2.5.6.0:

ID: 565090
Optimization the boot up for hardware variant 5
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(422), 1\9844_2.fw(422), 1\9844_3.fw(422), 1\9844_4.fw(422), 1\9844_5.fw(422)

Version 2.5.5.0:

ID: 551120
Startup time optimizations
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(421), 1\9844_2.fw(421), 1\9844_3.fw(421), 1\9844_4.fw(421), 1\9844_5.fw(421)

Version2.5.4.0:

ID: 540315 / Support ID: 400202320
BC sporadically notgoing into Operational due to X2X-bus problems at startup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(419), 1\9844_2.fw(419), 1\9844_3.fw(419),1\9844_4.fw(419)

Version 2.5.3.0:

ID: 523470 / Support ID: 400205694
safety modules not switching to operational state
SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(417), 1\9844_2.fw(417), 1\9844_3.fw(417), 1\9844_4.fw(417)

Version 2.5.2.0:

ID: 493885 / Support ID: 400103115, 400101850, 400154063, 400190752
First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(415), 1\9844_2.fw(415), 1\9844_3.fw(415), 1\9844_4.fw(415)

Version 2.5.0.0:

ID: 468060 / Support ID: 400178654
Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468065
optimization of X2X FW updates
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468070 / Support ID: 400177243
X2X FW update of several X2X modules is not working
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468530
CiR support
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\9844_1.fw(413), 1\9844_2.fw(413), 1\9844_3.fw(413)

Version 2.3.0.0:

ID: 454760
AS, System Designer support: cable redundancy
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 460105 / Support ID: 400168329
I/O modules behind POWERLINKbus controllers no longer achieving Operationalmode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 460225 / Support ID: 400150525
Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 466675
Module documentation revised
Data sheet V 2.32
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9844_1.fw(411), 1\9844_2.fw(411), 1\9844_3.fw(411)

Version 2.2.1.0:

ID: 449590
Error when running X20BC8084 (Rev. < G0) in base module X20BB80
Correction with new firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(401), 1\9844_2.fw(401), 1\9844_3.fw(401)

Version 2.2.0.0:

ID: 439100 / Support ID: 400150496
I/O modulesbehind POWERLINK bus controllers no longer achieving Operationalmode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 439205 / Support ID: 400128436
I/O modules behind POWERLINK bus controllers no longerachieving Operationalmode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(400), 1\9844_2.fw(400), 1\9844_3.fw(400)

Version 2.1.0.0:

ID: 404490
X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed.
When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change.
The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(300), 1\9844_2.fw(300), 1\9844_3.fw(300)

Version 2.0.0.0:

ID: 390280 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(210), 1\9844_2.fw(210), 1\9844_3.fw(210)

Version 1.3.7.0:

ID: 376980
With special constructions it could be that stations willbe lost.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(174), 1\9844_2.fw(174), 1\9844_3.fw(174)

Version 1.3.6.0:

ID: 326655
Link-Selektor funktion upgraded
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(169), 1\9844_2.fw(169), 1\9844_3.fw(169)

Version 1.3.5.0:

ID: 310790 / Support ID: 400097674
POWERLINK V1: Bug-fix for Up/Downgrade
POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 311025 / Support ID: 400051206
Expansion: Link- selector flag
New datapoints:&lt;br/&gt;- RedundancyFirstLinkState&lt;br/&gt;- RedundancySecondLinkState
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\9844_1.fw(168), 1\9844_2.fw(168), 1\9844_3.fw(168)

Version 1.3.4.0:

ID: 305155 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication tothe buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(167), 1\9844_2.fw(167), 1\9844_3.fw(167)

Version 1.3.3.0:

ID: 298990 / Support ID: 400090781
Problem with FW-Update of IO modules on Powerlink buscontrollers
The firmware update of IO modules does not work in certain configurations.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(165), 1\9844_2.fw(165), 1\9844_3.fw(165)

Version 1.3.2.0:

ID: 289020
Certain X2X configurations don't work
In very rare I/O constellations, the X2X modules don't start
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 291455
Upgrade1.3.1.0 on X20BC8084 to revision E0 may cause problems
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(164), 1\9844_2.fw(164), 1\9844_3.fw(164)

Version 1.3.0.0:

ID: 271200
Upgraded Kabelredundanz
support Hardwarevariant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277180
Support of 'Multiple Asynchronous Send'
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277750
New X2X datapoints
- NettimeOffsetX2X and NettimeX2X
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\9844_1.fw(160), 1\9844_2.fw(160), 1\9844_3.fw(160)

Version 1.2.1.0:

ID: 271200
Upgraded Kabelredundanz
support Hardwarevariant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(154), 1\9844_2.fw(154)

Version 1.2.0.0:

ID: 265540
Optimation of Kabelredundancy (Link Selector) ; Update behavioron X2X bus improved
- optimation of Kabelredundancy (Link Selector)
- faster updating of modules with big FW files on the X2X bus of the BC
- new objects: 20A3h, 2000h/9 and 20F0h/31
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\9844_2.fw(146)

Version 1.0.9.0:

ID: 220450
Extensions and Bugfixes
- Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765)
- Network-Failure-Detection did not work when BC_RedundancyTxMode_U8 = 1
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_2.fw(146)

Version 1.0.8.0:

ID: 218545
Extensions and Bugfixes
- Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1
- Support of PollResponse-Chaining
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9844_1.fw(145)

Version 1.0.4.0:

ID: 183390
New info-/diagnostic data points, new FW 1.39 for signal filter and corrections
New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9844_1.fw(141)

Version 1.0.3.0:

ID: 173290
First version of the buscontroller with cable redundancy
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9844_1.fw(138)