DWL@DWL10000104724

Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.1.0.0 * 24/03/2016 1 Mo EXE AS2.6_HW_80SD100XD.C044-01.exe
Description V2.7 HW Upgrade (80SD100XD.C044-01)

Revision information 80SD100XD.C044-01

Version 2.1.0.0:

ID: 469720
Error correction in order to guard motor outputs against short to ground
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42881_1.fw(106), 1\42881_2.fw(106), 1\42881_3.fw(106), 1\42881_4.fw(106), 1\42881_5.fw(106)

Version 2.0.0.0:

ID: 438760 / Support ID: 400157866
Drive is running in the function model motion in full-step mode
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42881_1.fw(104), 1\42881_2.fw(104), 1\42881_3.fw(104), 1\42881_4.fw(104)

Version 1.9.0.0:

ID: 400835
Cycle time of MPGen edjustable
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 400890
Function model Ramp: new mode
Mode -120: Set home position
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 400970
Corrected a problem in HWX file
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 434705 / Support ID: 400133806
Corrected HWC entry
Channel description changed:No
Configuration description changed: No
Firmware changed: No

ID: 434710
Insert in SG3 and CAN coupler is no longer possible
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42881_1.fw(101), 1\42881_2.fw(101), 1\42881_3.fw(101), 1\42881_4.fw(101)

Version 1.7.0.0:

ID: 288430 / Support ID: 400084530
Encoder position should be displayed at PosVal03,if SDC information is set to "on"
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 318995
Module bootup timeout configured
Channel description changed:No
Configuration description changed: Yes
Firmware changed: No

ID: 320765
Accelerated firmware update.
Allows reliable firmware update behind CANIO bus controllers.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42881_1.fw(14), 1\42881_2.fw(14), 1\42881_3.fw(14)

Version 1.6.3.0:

ID: 296365 / Support ID: 400087355
80SD100XD.C044-01: Erroneous Detection of Short Circuit between Motor-Phaseand Ground
Due to a Firmware-Error the activation of the Controller could be blocked under certain circumstances because of a wrongly assumed Short Circuit to Ground
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 298080
Support for HW-Variant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42881_1.fw(13), 1\42881_2.fw(13), 1\42881_3.fw(13)

Version 1.6.2.0:

ID: 290350 / Support ID: 400082483
In rare cases ACOPOSmicro generated an erroneous status indication (UZKStatus = not OK).
Also high motor currents in conjunction with tolerances of electronic components could lead to module internal disturbances which in consequence could generate error messages.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42881_1.fw(12), 1\42881_2.fw(12)

Version 1.6.1.0:

ID: 272340
Problem with the endswitch-reset at ramp mode.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42881_1.fw(11), 1\42881_2.fw(11)

Version 1.5.2.1:

ID: 243225
Customer-specific expansion of hardware description file
This upgrade has no impact on the Automation Studio and the standard version of the FieldbusDESIGNER
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42881_1.fw(8), 1\42881_2.fw(9)

Version 1.5.2.0:

ID: 232150/ Support ID: 400046062
Reference pulse on channel two doesn't work
Short circuit protection implemented
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42881_1.fw(8), 1\42881_2.fw(9)

Version 1.1.0.1:

ID: 204430
Support for buscontroller 80SD100XD.C044-01
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed:Yes
Firmware: 1\42881_1.fw(4), 1\42881_2.fw(4)

Version 1.0.0.0:

ID: 198950
Support for teh module 80SD100XD.C044-01
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42881_1.fw(2)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.7.0.0 * 07/07/2015 1,002 Ko EXE AS2.6_HW_80SD100XD.C044-01.exe
Description V2.7 HW Upgrade (80SD100XD.C044-01)

Revision information 80SD100XD.C044-01

Version 1.7.0.0:

ID: 288430 / Support ID: 400084530
Encoder position should be displayed at PosVal03, if SDC information is setto "on"
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 318995
Module bootup timeout configured
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID:320765
Accelerated firmware update.
Allows reliable firmware update behind CANIO bus controllers.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42881_1.fw(14), 1\42881_2.fw(14), 1\42881_3.fw(14)

Version 1.6.3.0:

ID: 296365 / Support ID: 400087355
80SD100XD.C044-01: Erroneous Detection of Short Circuit between Motor-Phaseand Ground
Due to a Firmware-Error the activation of the Controller could be blockedunder certain circumstances because of a wrongly assumed Short Circuit to Ground
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 298080
Support for HW-Variant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42881_1.fw(13), 1\42881_2.fw(13), 1\42881_3.fw(13)

Version 1.6.2.0:

ID: 290350 / Support ID: 400082483
In rare cases ACOPOSmicro generated an erroneous status indication (UZKStatus = not OK).
Also high motor currents in conjunction with tolerances of electronic components could lead to module internal disturbances which in consequence could generate error messages.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42881_1.fw(12), 1\42881_2.fw(12)

Version 1.6.1.0:

ID: 272340
Problem with the endswitch-reset at ramp mode.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42881_1.fw(11), 1\42881_2.fw(11)

Version 1.5.2.1:

ID: 243225
Customer-specific expansion of hardware description file
This upgrade has no impact on the Automation Studio and the standard version of theFieldbusDESIGNER
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42881_1.fw(8), 1\42881_2.fw(9)

Version 1.5.2.0:

ID: 232150 / Support ID: 400046062
Reference pulse onchannel two doesn't work
Shortcircuit protection implemented
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42881_1.fw(8), 1\42881_2.fw(9)

Version 1.1.0.1:

ID: 204430
Support for buscontroller 80SD100XD.C044-01
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\42881_1.fw(4), 1\42881_2.fw(4)

Version 1.0.0.0:

ID: 198950
Support for teh module 80SD100XD.C044-01
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42881_1.fw(2)
Loading
Retour à la liste

Veuillez sélectionner un pays et une langue

B&R Logo