DWL@DWL10000302970
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
2.5.4.0 | * | 05/07/2017 | 1 Mo | EXE | AS2.6_HW_X67BC8321-1.exe | |
Description |
V2.6 HW Upgrade (X67BC8321-1) Revision information X67BC8321-1 Version 2.5.4.0: ID: 540345 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(419), 1\7735_3.fw(419), 1\7735_4.fw(210), 1\7735_5.fw(419) Version 2.5.3.0: ID: 523560 / SupportID: 400205694 safety modules not switching to operational state SDOstreaming connection via UDP is not always established when PLC and SafeLogicare booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(417), 1\7735_3.fw(417), 1\7735_4.fw(210), 1\7735_5.fw(417) Version 2.5.2.0: ID: 493910 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\7735_1.fw(415), 1\7735_3.fw(415), 1\7735_4.fw(210), 1\7735_5.fw(415) Version 2.5.0.0: ID: 468175 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468180 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468185 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468570 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7735_1.fw(413), 1\7735_3.fw(413), 1\7735_4.fw(210), 1\7735_5.fw(413) Version 2.2.1.0: ID: 463210 hwx adaption Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(411), 1\7735_3.fw(411), 1\7735_4.fw(210), 1\7735_5.fw(411) Version 2.2.0.0: ID: 460135 / Support ID: 400168329 I/Omodules behind POWERLINK bus controllers no longer achieving Operationalmodeafter multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460255 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(411), 1\7735_3.fw(411), 1\7735_4.fw(210), 1\7735_5.fw(411) Version 2.1.0.0: ID: 433395 New hardware variant Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439130 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439235 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(400), 1\7735_3.fw(400), 1\7735_4.fw(210), 1\7735_5.fw(400) Version 2.0.1.0: ID: 433395 New hardware variant Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(210), 1\7735_3.fw(210), 1\7735_4.fw(210), 1\7735_5.fw(310) Version 2.0.0.0: ID: 355460 / Support ID: 400118600 Input Latch funktion works Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 390300 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(210), 1\7735_3.fw(210), 1\7735_4.fw(210) Version 1.3.4.0: ID: 310810 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311030 / Support ID: 400051206 Expansion: Link- selector flag New datapoints: RedundancyFirstLinkState and RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\7735_1.fw(168), 1\7735_3.fw(168) Version 1.3.3.0: ID: 305170 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost Whenthere was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(167), 1\7735_3.fw(167) Version 1.3.2.0: ID: 298995 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(165), 1\7735_3.fw(165) Version 1.3.1.0: ID: 289025 Certain X2X configurations don't work In very rare I/Oconstellations, the X2X modules don't start Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(163), 1\7735_3.fw(163) Version 1.3.0.0: ID: 277185 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277755 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7735_1.fw(160), 1\7735_3.fw(160) Version 1.2.0.0: ID: 246660 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic NodeAllocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 - support for Simulation device added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7735_1.fw(152),1\7735_3.fw(152) Version 1.0.8.0: ID: 218510 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(145) Version 1.0.7.0: ID: 214300 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(144) Version 1.0.6.1: ID: 214050 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart(A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configurationentries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(144) Version 1.0.6.0: ID: 210935 Extensions and Bugfixes - Error correction for operation in Powerlink V1networks (A&P 210765) Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\7735_1.fw(143) Version 1.0.5.0: ID: 209590 Extensions and Bugfixes - New ASICS will be set to 3mA output current (A&P 182905) - Optimization of SDO communication (unnecessary acknowledges removed) - Support of commands ReadMultipleParameter / WriteMultipleParameter - NodeID assignment by digital inputs supported (NodeId 241 and 242) - Minor corrections certification - ASnd frames with unknown ServiceID could disturb the BC(only possible with 3rd party MN) - Access to not existing objects in ODcould cause firmware crash - When running X2X cycle times <200 us the X2X Bus was not working correctly (A&P 190630) - When in state PREOP_2 no SoC is received for 10sec the BC will fall back in PREOP_1 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(142) Version 1.0.4.0: ID: 160527 New info-/diagnostic data points, new FW 1.41 for signal filter andcorrections New info-/diagnostic data points in HWC, new FW 1.41 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(141) Version 1.0.3.0: ID: 173300 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857 und 171987) - Optimizations for operation in 200us networks - 2 nodes with the same node number generated disturbance on the network (A&P 166040) - Functions for a new firmware download mechanism implemented (A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(138) Version 1.0.2.0: ID: 164670 Extensions - Extensions for operation with Safety Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7735_1.fw(136) |