General information
Support
Dynamic node allocation (DNA) Yes
Certifications
CE Yes
UKCA Yes
CRA (Cyber Resilience Act) Evaluation ongoing
Functional safety Yes
UL cULus E225616
Power conversion equipment
KC Yes
B&R ID code 0xA8E4
Cooling and mounting type Cold plate or pass-through mounting
Slots for plug-in modules 2
DC bus connection
Voltage
Nominal 750 VDC
Power dissipation depending on switching frequency
Switching frequency 5 kHz [0.65 * IM² - 0.35 * IM+ 64] W
Switching frequency 10 kHz [2.16 * IM² - 10.912 * IM+ 190] W
Continuous power consumption 32.37 kW
DC bus capacitance 1320 µF
Variant ACOPOSmulti backplane
24 VDC power supply
Input voltage 25 VDC ±1.6%
Input capacitance 23.5 µF
Max. power consumption 21 W + PSLOT1 + PSLOT2 + P24 V Out + PHoldingBrake(s)
Variant ACOPOSmulti backplane
24 VDC output
Output voltage
DC bus voltage (UDC): 260 to 315 VDC 25 VDC * (UDC/315)
DC bus voltage (UDC): 315 to 800 VDC 24 VDC ±6%
Quantity 2
Fuse protection 250 mA (slow-blow) electronic, automatic reset
Motor connection
Reduction of continuous current depending on switching frequency and mounting type
Switching frequency 5 kHz
Cold plate mounting 0.99 A/K (starting at 40°C)
Pass-through mounting 0.52 A/K (starting at 40°C)
Switching frequency 10 kHz
Cold plate mounting 0.29 A/K (starting at 10°C)
Pass-through mounting 0.23 A/K (starting at 0°C)
Reduction of continuous current depending on installation elevation
Starting at 500 m above sea level 2.2 Aeff per 1000 m
Protective measures
Overload protection Yes
Short-circuit and ground fault protection Yes
Variant
U, V, W, PE Connector
Shield connection Yes
Terminal connection cross section
Flexible and fine-stranded wires
With wire end sleeve 0.25 to 6 mm²
Approbation data
UL/C-UL-US 30 to 10 AWG
CSA 28 to 10 AWG
Max. motor line length depending on switching frequency
Switching frequency 5 kHz 25 m
Switching frequency 10 kHz 25 m
Quantity 2
Continuous power per motor connection 16 kW
Continuous current per motor connection 22 Aeff
Peak current per motor connection 55 Aeff
Nominal switching frequency 5 kHz
Possible switching frequencies 5 / 10 kHz
Insulation stress of the connected motor per IEC TS 60034-25:2004 Limit value curve A
Max. output frequency 598 Hz
Terminal cable cross section dimension of shield connection 12 to 22 mm
Motor holding brake connection
Protective measures
Overload and short-circuit protection Yes
Open-circuit monitoring Yes
Undervoltage monitoring Yes
Quantity 2
Output voltage 24 VDC +5.8% / -0%
Continuous current per connection 2.1 A
Max. internal resistance 0.3 Ω
Extinction potential Approx. 30 V
Max. extinction energy per switching operation 3 Ws
Max. switching frequency 0.5 Hz
Response threshold for open-circuit monitoring Approx. 0.5 A
Response threshold for undervoltage monitoring 24 VDC +0% / -4%
Enable inputs
Electrical isolation
Input - Inverter module Yes
Input - Input Yes
Input voltage
Nominal 24 VDC
Maximum 30 VDC
Switching threshold
Low <5 V
High >15 V
Switching delay at nominal input voltage
Enable 1 → 0, PWM off Max. 20.5 ms
Enable 0 → 1, ready for PWM Max. 100 µs
Quantity 4 (2 per axis)
Circuit Sink
Input current at nominal voltage Approx. 30 mA
Modulation compared to ground potential Max. ±38 V
OSSD signal connections Permitted
Max. test pulse length: 500 µs
Trigger inputs
Electrical isolation
Input - Inverter module Yes
Input - Input Yes
Input voltage
Nominal 24 VDC
Maximum 30 VDC
Switching threshold
Low <5 V
High >15 V
Switching delay
Rising edge 52 µs ±0.5 µs (digitally filtered)
Falling edge 53 µs ±0.5 µs (digitally filtered)
Quantity 2
Circuit Sink
Input current at nominal voltage Approx. 10 mA
Modulation compared to ground potential Max. ±38 V
Temperature sensor connection
Quantity 2
Resistance range 500 Ω to 5 kΩ
Electrical properties
Energy efficiency (IE classification)
Power dissipation relative to continuous apparent power IE2 (10,25) 1.1%
IE2 (50,25) 1.1%
IE2 (10,50) 1.3%
IE2 (50,50) 1.4%
IE2 (90,50) 1.4%
IE2 (10,100) 2%
IE2 (50,100) 2%
IE2 (90,100) 2%
Nominal losses in standby mode 10 W
Discharge capacitance 0.44 µF
Operating conditions
Permissible mounting orientations
Hanging vertically Yes
Horizontal, face up Yes
Standing horizontally No
Installation elevation above sea level
Nominal 0 to 500 m
Maximum 4000 m
Pollution degree per EN 61800-5-1 2 (non-conductive pollution)
Overvoltage category per EN 61800-5-1 III
Degree of protection per EN 60529 IP20
Ambient conditions
Temperature
Operation
Nominal 5 to 40°C
Maximum 55°C
Storage -25 to 55°C
Transport -25 to 70°C
Relative humidity
Operation 5 to 85%
Storage 5 to 95%
Transport Max. 95% at 40°C
Mechanical properties
Dimensions
Depth
Cold plate 212 mm
Pass-through mounting 209 mm
Width 106.5 mm
Height 317 mm
Weight Approx. 4.4 kg
Module width 2
Materiaalnummer:
8BVI0220HCD0.000-1
Omschrijving:
  • Integrated uncontrolled standstill and safe stop
  • Integrated connection for motor holding brake and temperature sensor
  • 2 slots for ACOPOSmulti plug-in modules
  • Two fully independent power inverters in one inverter module contained in 2-axis modules
ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
Vereiste toebehoren
Terminal block sets
8BZVI0220D0.000-1A ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
Optionele toebehoren
Accessory sets
8BXB000.0000-00 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
Fan modules
8BXF001.0000-00 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
POWERLINK/Ethernet cables
X20CA0E61.00020 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
X20CA0E61.00025 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
X20CA0E61.00030 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
X20CA0E61.00035 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
X20CA0E61.00050 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
X20CA0E61.00100 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
Plug-in modules
8BAC0120.000-1 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8BAC0120.001-2 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8BAC0121.000-1 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8BAC0122.000-1 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8BAC0123.000-1 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8BAC0123.001-1 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8BAC0123.002-1 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8BAC0124.000-1 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8BAC0125.000-1 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8BAC0130.000-1 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8BAC0130.001-1 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8BAC0132.000-1 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8BAC0133.000-1 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
Shield component sets
8SCS000.0000-00 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8SCS002.0000-00 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8SCS005.0000-00 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8SCS009.0000-00 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
Terminal blocks
8TB2104.203F-00 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8TB2104.203L-00 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8TB2108.2010-00 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8TB2112.2010-00 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8TB3104.204G-11 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
8TB3104.204K-11 ACOPOSmulti inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes
Automation Studio HW Upgrades Versie (Datum) Download
V3.0 HW Upgrade (8BVIxxxxxxDx.xxx-x) EXE / 396 KB
V4.0 HW Upgrade (8BVI0220HCD0.000-1) EXE / 291 KB
V4.0 HW Upgrade (8BVIxxxxxxDx.xxx-1) EXE / 582 KB
V4.0 HW Upgrade (8BVIxxxxxxDx.xxx-x) EXE / 383 KB
V6.0 HW Upgrade (8BVI0220HCD0.000-1) EXE / 364 KB
V6.0 HW Upgrade (8BVIxxxxxxDx.xxx-1) EXE / 306 KB
V6.0 HW Upgrade (8BVIxxxxxxDx.xxx-x) EXE / 306 KB
Certificaten Versie (Datum) Download
ACOPOSmulti KC certificates ZIP / 3 MB
E225616 UL Certificate of Compliance ACOPOSmulti (UL 508C) PDF / 282 KB
E225616 UL Certificate of Compliance ACOPOSmulti (UL 61800-5-1) PDF / 183 KB
EU Declaration FS Servos ACOPOSmulti PDF / 986 KB
EU Declaration Servos ACOPOSmulti PDF / 963 KB
TÜV-certificate - function "Safe Pulse Disabling" for ACOPOSmulti PDF / 1 MB
UK Declaration FS Servos ACOPOSmulti PDF / 341 KB
UK Declaration Servos ACOPOSmulti PDF / 337 KB
Documentatie Versie (Datum) Download
ACOPOSmulti User´s Manual PDF / 308 MB
Datasheet 8BVI0220HCD0.000-1 PDF / 2 MB
E-CAD (Electro of EPLAN Templates) Versie (Datum) Download
ACOPOSmulti EPLAN P8 from V2.4 EXE / 81 MB
M-CAD (Mechan. Templates) Versie (Datum) Download
3D file STEP 8BVI0220HCDx.000-x ZIP / 169 KB

Graag land en taal kiezen