DWL@DWL10000878227

仕様版 言語
オペレーティングシステム
日付
サイズ
タイプ ダウンロード
1.2.3.1 * 2026/10/07 777 KB EXE AS6_HW_X20DO4623.exe
説明 V6.0 HW Upgrade (X20DO4623)

Revision information X20DO4623

Version 1.2.3.1:

ID:
Firmware signature enables automatic verification of the authenticity on the target system
The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source.
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.2.2.0:

ID: 767195
Modul enabled for operation on X2X+
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\9852_5.fw(801)

Version 1.2.1.0:

ID: 734695
Adaptations for Automation Studio 4.11
Description of AC power supply corrected
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\9852_5.fw(801)

Version 1.2.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.1.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.0.4.0:

ID: 639305
Module documentation revised
Data sheet V3.22
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9852_5.fw(801)

Version 1.0.3.1:

ID: 395475
Enhancements packed data point for outputs
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID:396645
Enhancement online-help files
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9852_5.fw(801)

Version 1.0.3.0:

ID: 387010
Signaltypes for APROL corrected
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\9852_5.fw(801)

Version 1.0.1.1:

ID: 345045
Correction of autoconnect function
In Automation Studio 4, the X20DO4623 will be inserted with X20BM12 (red) instead of X20BM11 (gray).
Channel description changed:No
Configuration description changed: No
Firmware changed: No
Firmware: 1\9852_5.fw(801)

Version 1.0.1.0:

ID: 217495
Adaptation UART Re-Init
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\9852_5.fw(801)
Loading