DWL@DWL10000878111
| 仕様版 | 言語 | オペレーティングシステム | 日付 | サイズ | タイプ | ダウンロード |
|---|---|---|---|---|---|---|
| 1.9.2.1 | * | 2026/10/06 | 1 MB | EXE | AS6_HW_X20cIF2181-2.exe | |
| 説明 |
V6.0 HW Upgrade (X20cIF2181-2) Revision information X20cIF2181-2 Version 1.9.2.1: ID: Firmware signature enables automatic verification of the authenticity on the target system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source. Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.9.2.0: ID: 705170 Not possible to use both connectors on X20IF2181-2 when is used as Ethernetdevice Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57914_0.pci(59148), 1\57914_1.pci(59138), 1\57914a0.epl(231), 1\57914a1.epl(231) Version 1.9.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.8.0.0: ID: 695380 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operated in operating mode "Ethernet" and connected to a POWERLINK network in this mode, the interface could fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57914_0.pci(59148), 1\57914_1.pci(59138), 1\57914a0.epl(231), 1\57914a1.epl(231) Version 1.7.1.0: ID: 698365 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57914_0.pci(58636), 1\57914_1.pci(58625), 1\57914a0.epl(229), 1\57914a1.epl(229) Version 1.7.0.0: ID: 679535 Support HW-variant 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57914_0.pci(58636), 1\57914_1.pci(58625), 1\57914a0.epl(229), 1\57914a1.epl(229) Version 1.6.0.0: ID: 675065 CPURED: Bus controller shows ModuleOK = FALSE during CPU redundancy switchover Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57914_0.pci(58636), 1\57914a0.epl(229) Version 1.5.0.0: ID: 629335 Module documentation revised Data sheet V1.15 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 629355 Controller redundancy and ring redundancy: When using controller redundancy and ring redundancy, the redundancy switchover or the opening or closing of the ring could lead to the failure of CNs, especially with larger network expansions. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57914_0.pci(58124), 1\57914a0.epl(227) Version 1.4.0.0: ID: 573850 Support HW-Revision DO Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57914_0.pci(56586), 1\57914a0.epl(221) Version 1.3.3.0: ID: 542400 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmwareit could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57914_0.pci(56330), 1\57914a0.epl(220) Version 1.3.2.0: ID: 518145 Controller redundancy + ring redundancy: When the ring is broken, the "Switchover level"changes to "Major bump switchover possible". Automation Runtime version >=C4.26 or A4.33 is also needed for this. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57914_0.pci(56074), 1\57914a0.epl(219) Version 1.3.1.0: ID: 502085 Controller – Redundanz + Ringredundanz: the combination of Controller – Redundanz + Ringredundanz with a broken ring could lead to fail of CN´s Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 504065 X20-Compact-S support Channel description changed: No Configuration description changed: No Firmware changed: No ID: 504185 Module documentation revised Data sheet V1.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:1\57914_0.pci(55818), 1\57914a0.epl(218) Version 1.1.1.0: ID:457675 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460280 Controller redundancy: POWERLINK cycle time violation caused by configured but unconnected controlled nodes during redundancy switchover Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57914_0.pci(54791), 1\57914a0.epl(214) Version 1.1.0.0: ID: 449785 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57914_0.pci(54279), 1\57914a0.epl(212) Version 1.0.0.0: ID: 342395 Support X20cIF2181-2 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 1\57914_0.pci(52998), 1\57914a0.epl(207) |
|||||