DWL@DWL10000878796
| 仕様版 | 言語 | オペレーティングシステム | 日付 | サイズ | タイプ | ダウンロード |
|---|---|---|---|---|---|---|
| 2.1.2.1 | * | 2026/10/09 | 559 KB | EXE | AS6_HW_5PC910.SX05-00.exe | |
| 説明 |
V6.0 HW Upgrade (5PC910.SX05-00) Revision information 5PC910.SX05-00 Version 2.1.2.1: ID: Firmware signature enables automaticverification of the authenticity on thetarget system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source. Channel description changed: no Configuration description changed: yes Firmwarechanged: no Version 2.1.2.0: ID: 757525 New MTCX FW V01.32 for APC910 New MTCX FW V01.32 for APC910 with following changes: - Optimized internal power supply. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\55364_0.fw(132) Version 2.1.1.0: ID: 749925 New MTCX FW V01.31 for APC910 New MTCX FW V01.31 for APC910 with following changes: - Optimization of the SDL interface in combination with DVI panels. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\55364_0.fw(131) Version 2.1.0.0: ID: 665675 Wear level of storage medium from AR A4.90: Additional data point to display the wear level in %. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 670619 Extensions Hypervisor from AR A4.81 USB allocation between GPOS and RTOS also possible on the Automation Panel.This requiresthat the appropriate hardware upgrades are used for all components (APC/PPC, AP, SDLx Receiver, SDLx Transmitter). Starting with AS 4.8 following HWX upgrades (or newer) are recommended for APC910 + TS17 CPU, mixed operation of the current and older HWX upgrades is not recommended: APC910 system unit: V2.1.0.0 5PC900.TS17-xx: V2.1.0.0 5AC901.LSD3-00: V2.0.0.0 5AC901.LSD4-00: V2.0.0.0 Automation Panels: V2.0.0.0 AP5000 extension unit: V2.0.0.0 Automation Panel SDLx Receiver: V2.0.0.0 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\55364_0.fw(127) Version 2.0.3.0: ID: 604509 Enhancements for APROL Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 637855 New MTCX FW V01.27 for APC910 New MTCX FW V01.27 for APC910 with following changes: - Optimized internal keyboard syncronization. - Optimized internal power supply syncronization. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 645725 Soft reset support for hypervisor target systems. From version AR 4.71 an independent reboot of AR and GPOS is possible. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\55364_0.fw(127) Version 2.0.2.0: ID: 617090 Bugfix for the ETHinternal interface ModbusTCP and OPC UA are working now for the ETHinternal. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\55364_0.fw(125) Version 2.0.1.0: ID: 606455 New MTCX FW V01.25 for APC910 New MTCX FW V01.25 for APC910 with following changes: - Support for IF option 5AC901.I232-00 implemented. - Enhancements for B&R Hypervisor. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\55364_0.fw(125) Version 2.0.0.0: ID: 566580 Preperation to support the B&R Hypervisor The B&R Hypervisor is supported with Automation Studio version V4.4. Channel description changed: No Configuration description changed: Yes Firmware changed: No Version1.4.2.0: ID: 566530 New MTCX FW V01.24 for APC910 New MTCXFW V01.24 for APC910 with following changes: - Support for SDL4. - Support for B&R Hypervisor. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\55364_0.fw(124) Version 1.4.1.0: ID: 513075 Adeption for the support of Intel Skylake CPUs The 5PC900.TS17-xx are supported from this hardware upgrade version. The Intel Skylake CPUs are generally supported fromAutomation Studio 4.3.3 and Automation Runtime 4.33. Channel descriptionchanged: No Configuration description changed: Yes Firmware changed: No ID: 540565 Serial interface can be deactivated again Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\55364_0.fw(121) Version 1.3.9.0: ID: 527620 New MTCX FW V01.21 for APC910 New MTCX FW V01.21 for APC910 with following changes: - Support for IF option 5AC901.ICAN-01. - Bugfix: Run Led was not cleared in standby mode. - Bugfix: SW-Reset and Watchdog for 5PC900.TS17-xx CPU modules. - BIOS enhancement for the TPM and Boot Option Sorting Method for 5PC900.TS17-xx CPU modules implemented. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\55364_0.fw(121) Version 1.3.8.0: ID: 491440 New MTCX FW V01.20 for APC910 New MTCX FW V01.20 for APC910 with following changes: - Optimization of the Suspend/Resume function for USB devices connected with SDL-Link. - Bugfix: the combination SDL cables with extender (5CASDL.0xx0-13) and Realtime Environment option set to enabled in BIOS, can cause in very rare cases a system hang at bootup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\55364_0.fw(120) Version 1.3.7.0: ID: 481360 New MTCX FW V01.19 for APC910 NewMTCX FW V01.19 for APC910 with following changes: - Bugfix: sporadical verify problems during a FW upgrade on a Automation Panel connected with SDL. The problem is actually only seen with long SDL cables starting with 20m. - Bugfix: with operating temperatures under 5°C, there are sporadic problemsduring the SDL connection establishment using the SDL cable with extender (5CASDL.0xx0-13). - Bugfix: using the HMI Service Center (5SWUTI.0001-000) the Power LED was set in a wrong state. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\55364_0.fw(119) Version 1.3.6.0: ID: 472185 New MTCX FWV01.17 for APC910 New MTCX FW V01.17 for APC910 with following changes: - Optimized SDL equalizer settings. - Workaround for customer spezific PCIe card. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\55364_0.fw(117) Version 1.3.5.0: ID: 460030 New MTCX FW V01.16 for APC910 New MTCX FW V01.16 for APC910 with following changes: - Support for AP5000 Key Extensions. - Optimization of the maximum inrush current at minimum input voltage of the APC910 system. - Bugfix: "Thermal Runaway" effect of the5AC901.BUPS-xx battery units. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\55364_0.fw(116) Version 1.3.3.0: ID: 436040 Bugfix for Modbus TCP with ARwin From Automation Studio version 4.1 and ARwin version G4.10 on the APC910 can be used as Modbus TCP slave. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 437555 New MTCX FW V01.14 for APC910 New MTCX FW V01.14 for APC910 with following changes: - Bugfix: if a 5AC901.IUPS-xx (internal UPS) is used without a 5AC901.BUPS-xx (battery unit) under AR, no NMI wasgenerated in a PowerFail case. With normal UPS operation (with connected battery unit) this problem does not occur. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\55364_0.fw(114) Version 1.3.1.0: ID: 416825 MTCX Upgrade to version V01.13 New MTCX FW V01.13 with following changes: - Bugfix: sporadic problem with jumping cursor on Intelli touchscreens (customized systems). - Support: FW upgrade for the external SDL3 converterbox (5COSD3.1000-00). - Support for IF option 5AC901.ISIO-00. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\55364_0.fw(113) Version 1.3.0.0: ID: 392515 Optimized Power Supply and Support for Smart Display Link 3 (SDL3) - In very rare cases there is a Power On problem, this problemcan only occur in combination with MTCX FW V1.11 and 5AC901.I485-00. During Power On the power LED of the APC910 flashes red/green before the APC910 starts. Typically this problem combination is detected during functional test at B&R side and is not delivered in the field. - Automation Studio 4.x only: The SDL3 Transmitter can be inserted in the new Slot SL3. To configure a SDL3 Panel following upgrades have to be installed, too: SDL3 Transmitter: 5AC901.LSD3-00 V1.0.0.0 SDL3 Receiver:5DLSDL.1001-00 V1.0.0.0 Automation Panel 9x3: 5AP9x3.xxxx-xx V1.2.0.0 Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\55364_0.fw(112) Version 1.2.0.0: ID: 376625 New MTCX version V1.11 - Power Supply 12V residual voltage reduced. - Power supply voltage peaks improved. - Power supply change because of clampdiods. - USB on the 2. Display (Daisy Chain) possible. - PS/2 error on APXXX displays fixed.. - Bios extention for SATA and Runtime Default/Enable. - SDL/3: Additional IRQ controllefor SDL/3 - Workaraund for batteries, which become too hot. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\55364_0.fw(111) Version 1.1.1.3: ID: 376085 Automatic touch calibration, for the new generation Automation Panel (AP923/AP92D) with resistive touch screen, inserted. The touch screen is calibrated automatically with the AP923/AP92D from versions: AS: 4.0.17.85 AR: H4.06 VC: 4.05.6 Panel upgradeversion: V1.1.0.0 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\55364_0.fw(102) Version 1.1.0.3: ID: 348285 The Slots SS1 and SS2 can now be used Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\55364_0.fw(102) Version 1.1.0.2: ID: 341470 A display can be configured The display slot (DS) was added for Automation Studio V3.0.90.x. Note: Starting with Automation Studio Version V3.0.90.27 SP09 + Visual Components V3.96.0 on a visualization can be operated on the APC910. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\55364_0.fw(102) Version 1.1.0.1: ID: 343040 New MtcX version V1.02 - Enhancements and optimizations power supply. - Bugfix: Third party DVI panels work now correctly. - Bugfix: Problems with short voltage interception are solved (it is also necessary to update the boardcontroller firmware of the CPU board to fix it completly. This firmware can be downloaded fromB&R homepage.). - Bugfix: Sporadic PowerOn problem is solved. This PowerOnproblem can only occur with MtcX version V01.01, all other MtcX versions are not affected. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\55364_0.fw(102) Version 1.0.0.0: ID: 336365 Support for 5PC910.SX05-00 and important notes - ARemb: It is currently not possible to run a visualization under ARemb onAPC910. Therefore it is not possible to configure a panel. This possibility will be offered at a later date. - In cases of very short power supply interruptions it may happen, that the MtcX "loses" the factory settings of the CPU board. As a result the AutomationRuntime is not able to identify the CPU board. The Automation Runtime will start in service mode. To avoid this problem, a power supply interruption of at least one second should be performed. This error will be fixed in the next firmware versions of MtcX and the CPU board controller. Please note: The minimum version of Automation Runtime, which is necessary for the operation of an APC910, is Q4.02! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\55364_0.fw(8) |
|||||