DWL@DWL10000878269
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
|---|---|---|---|---|---|---|
| 1.4.1.1 | * | 07/10/2026 | 5 MB | EXE | AS6_HW_X20IF1063-1.exe | |
| Beskrivelse |
V6.0 HW Upgrade (X20IF1063-1) Revision information X20IF1063-1 Version 1.4.1.1: ID: Firmware signature enables automatic verification of the authenticity on the target system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installedfirmware is unchanged and comes from a trusted source. Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration descriptionchanged: yes Firmware changed: no Version 1.3.0.0: ID: 627890 Replacement of the interfacecard in AS "Replace HW Modul" works correktly Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 703335 Firmware libraries updated to latest release. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42775a1.fw(21), 1\42775_1.fw(13) Version 1.2.4.0: ID: 468910 netX configuration module name can be defined for X20IF1063-1 in AS 4 atSGCCPU Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42775a1.fw(20), 1\42775_1.fw(12) Version 1.2.3.0: ID: 236405 Add ModulOK in I/O Mapping Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 466345 FDT/DTM Cycle Time change Change parameter name "Cycle time [µs]" to "Data exchange time (CPU-netX) [µs]" Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42775a1.fw(20),1\42775_1.fw(12) Version 1.2.2.0: ID: 431380 Internal error 6999 when creating a project Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42775a1.fw(20), 1\42775_1.fw(12) Version 1.2.0.0: ID: 357110 Dynamic configuration The name of the generated netX module can be freely assigned in order to enable a dynamic configuration of netX modules in AR. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 371475 New firmware: PNO certification Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\42775a1.fw(20), 1\42775_1.fw(12) Version 1.1.2.0: ID: 307815 Dynamic node number for netX Profibus slaves Possibility to set the node number dynamically for the X201063-1 netX Profibus slave by a library FUB. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42775a1.fw(19), 1\42775_1.fw(12) Version 1.1.0.1: ID: 257425 Vendor ID changed Module identifies with B&R Vendor ID now Caution! This upgrade requires changed settings onthe master using the latest GSD file. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42775a1.fw(18), 1\42775_1.fw(12) Version 1.0.2.0: ID: 240730 X20 Interface PROFIBUS DP Slave, Configuration of netX cycle time X20 Interface PROFIBUS DP Slave, Configuration of netX cycle time. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42775a1.fw(16), 1\42775_1.fw(12) Version 1.0.1.1: ID: 237610 Interface module PROFIBUS DP Slave,new online help Interface module PROFIBUS DP Slave, new online help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42775a1.fw(16), 1\42775_1.fw(12) Version 1.0.1.0: ID: 235850 Interface module PROFIBUS Slave,first version Interface module PROFIBUS Slave, first version Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42775a1.fw(16), 1\42775_1.fw(12) |
|||||