1.5.1.1 * 07/10/2026 2 MB EXE AS6_HW_X20DS1928.exe
Beskrivelse V6.0 HW Upgrade (X20DS1928)

Revision information X20DS1928

Version 1.5.1.1:

ID:
Firmware signature enables automatic verification of the authenticity on the target system
The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source.
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.5.0.0:

ID: 731420
Support new HW variant 2
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43282_1.fw(131), 1\43282_2.fw(141)

Version 1.4.0.0:

ID:
Adaptations for Automation Studio4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.3.1.0:

ID: 675455
Correction in the help.
Wrong help post was removed.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\43282_1.fw(131)

Version 1.3.0.0:

ID: 658350
EnDat error after warm restart of CPU
If the module is restarted, e.g. during CPU warm restart, it may happen that a busy bit remainsset for the connected EnDat sensor.
This must first be acknowledged again before EnDat communication can continuewithout errors. The corresponding acknowledgment has been implemented in firmware version greater 1.30.
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 673250
Automatic error acknowledgement after sensor restart implemented
Automatic EnDat error acknowledgement on restart implemented to match the official EnDat specification
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 674840
Module documentation revised
Data sheet V1.30
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\43282_1.fw(131)

Version 1.1.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.0.3.0:

ID: 309075
new register overwiew (dokumentation)
revised fitting of dokumentation
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 428290
Documentation changed
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\43282_1.fw(3)

Version 1.0.2.0:

ID: 311520
Add-On - OCTET-Datapoints
OCTET-Datapoints implemented
(better Handling of flat stream interface)
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 311545
Support X20DS1928
Support for AutomationStudio incl. documentation
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43282_1.fw(3)

Version 1.0.0.2:

ID: 231365
Support of X20DS1928 EnDat
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 254475
discontinued
Problem solved - Help file adapted
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: Firmware\43282_1.fw(3)