DWL@DWL10000879200
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
|---|---|---|---|---|---|---|
| 1.9.0.1 | * | 13/10/2026 | 795 KB | EXE | AS6_HW_5ACPCI.XPNS-00.exe | |
| Beskrivelse |
V6.0 HW Upgrade (5ACPCI.XPNS-00) Revision information 5ACPCI.XPNS-00 Version 1.9.0.1: ID: Firmware signature enables automaticverification of the authenticity on thetarget system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source. Channel description changed: no Configuration description changed: yes Firmwarechanged: no Version 1.9.0.0: ID: 775400 FDT/DTM Cycle Time change Change parameter name "Cycle time [µs]" to "Data exchange time (CPU-netX) [µs]" Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 775410 Upgraded field bus FW versions Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45520a1.fw(103) Version 1.8.0.0: ID: 730345 Denial of Service vulnerability in PROFINET IO Device solved. Denial of Service vulnerability in PROFINET IO Device solved. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45520a1.fw(102) Version 1.5.1.0: ID: 628735 Exchange in Automation Studio optimized The replacement of the module works now correctly. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 634590 Dynamic configuration The name of the generated netX module can be freely assigned in order to enable a dynamic configuration of netX modules in AR. Channel descriptionchanged: No Configuration description changed: Yes Firmware changed: No Firmware: 1\45520a1.fw(101) Version 1.5.0.0: ID: 515705 DMA is activated again Attention: In rare cases it was possible,that an inconsistency in data transmission arised in combination with third party devices. This problem is fixed with the hardware revision E0 of the 5ACPCI.XPNS-00. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45520a1.fw(101) Version 1.3.0.0: ID: 420055 Profinet communication stuck Included new firmware version 3.5.52.1 and deactivated DMA Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\45520a1.fw(100) Version 1.2.0.2: ID: 377895 Added additional datapoints in the I/O Mapping New datapoints: ModuleOK, SerialNumber, ModuleID, HardwareVariant, FimrwareVersion Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\45520a1.fw(04) Version 1.2.0.1: ID: 369965 Parameter added Parameter "Manual start of bus communication" has been added in the I/O configuration. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\45520a1.fw(04) Version 1.0.1.2: ID: 240485 Configuration of netX cycle time The cycle time for data exchange between CPU and netX can be configured now. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\45520a1.fw(3), 1\45520_1.fw(1) |
|||||