DWL@DWL10000877980
| Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
|---|---|---|---|---|---|---|
| 1.10.2.1 | * | 06.10.2026 | 3 MB | EXE | AS6_HW_X20AI1744.exe | |
| Popis |
V6.0 HW Upgrade (X20AI1744) Revision information X20AI1744 Version 1.10.2.1: ID: Firmware signature enables automatic verification of the authenticity on the target system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source. Channel description changed: no Configuration description changed: yes Firmware changed:no Version 1.10.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.9.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.8.4.0: ID: 639690 Module documentation revised Data sheet V 4.24 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7390_2.fw(9), 1\7390_3.fw(140) Version 1.8.3.0: ID: 603789 APROL: missing attribute for channel-parameter with "Sig_*" inserted Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7390_2.fw(9), 1\7390_3.fw(140) Version 1.8.2.0: ID: 560910 Module documentation revised Data sheet V 4.23 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7390_2.fw(9), 1\7390_3.fw(140) Version 1.8.1.0: ID: 560910 Module documentation revised Data sheet V 4.23 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7390_2.fw(9), 1\7390_3.fw(140) Version 1.8.0.0: ID: 531180 Module documentation revised Data sheet V 4.20 Channel description changed: No Configuration description changed: No Firmware changed: No ID:535280 Synchronization does not work In synchronous mode can it happen, the A / D converter could not synchronize to the X2X. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7390_2.fw(9), 1\7390_3.fw(140) Version 1.7.0.0: ID: 501875 Module documentation revised Datasheet V 4.11 Channel description changed: No Configuration description changed:No Firmware changed: No ID: 512595 Error value corrected In case "invalid value", the analog input shows the documented error value Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7390_2.fw(9), 1\7390_3.fw(130) Version 1.6.0.0: ID: 497325 Modules of revision> = H0 were not backward compatible in mode multisample. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\7390_2.fw(9), 1\7390_3.fw(111) Version 1.5.0.0: ID: 475115 Documentation revised. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 485955 Correction - new firmware for hardware version 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7390_2.fw(9), 1\7390_3.fw(110) Version1.4.0.0: ID: 467580 support HW-Variante 3 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7390_2.fw(9), 1\7390_3.fw(100) Version 1.3.0.2: ID: 423695 HW file spellcheck Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7390_2.fw(9) Version 1.3.0.1: ID: 359760 englisch documentation updated Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7390_2.fw(9) Version 1.3.0.0: ID: 345275 Improved method for prevention of mutual measurement interference by adjacent modules Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 351330 Extensions in function model multisampling Channel description changed: Yes Configuration descriptionchanged: Yes Firmware changed: Yes Firmware: 1\7390_2.fw(9) Version 1.2.5.0: ID: 328534 Incorrect entry of AnalogInput01 resolved Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7390_2.fw(6) Version1.2.3.0: ID: 261660 Changes for AS3.0.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7390_2.fw(6) Version 1.2.2.0: ID: 256670 Extensions for AS 3.0.90 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7390_2.fw(6) Version 1.2.1.0: ID: 243660 Value of the X20AI1744 is oscillating if several X20AI1744 are plugged sideby side Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7390_2.fw(6) Version 1.2.0.0: ID: 256630 New function model (multisample) Channel description changed: No Configuration description changed: Yes Firmware changed:Yes Firmware: 1\7390_2.fw(5) Version 1.1.0.0: ID: 256635 Extension of the gain-range: 2mV/V bis 256mV/V Channel description changed: No Configuration description changed: Yes Firmware changed:Yes Firmware: 1\7390_2.fw(4) Version 1.0.2.0: ID: 217820 It last up to 40sec until the ADC is in synchronous mode Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\7390_2.fw(3) |
|||||