V6.0 HW Upgrade (X20cPS3300) Revision information X20cPS3300 Version 1.5.0.2: ID: Firmware signature enables automatic verification of the authenticity on the target system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source. Channel descriptionchanged: no Configuration description changed: yes Firmware changed: no Version 1.5.0.1: ID: QCAS-3535 CVE-2025-43715: Installer is vulnerable to local privilege escalation The installation system NSIS used by B&R can allow local attackers toescalate their privileges. CVE-2025-43715, CVSS: 8.1 (High) CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.5.0.0: ID: TDYD-9096 The current limit values have been standardized on the HW variants. The warning LED is activated from 1.5 A. From 2.3 A, the error bit and the error LED are set. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57107_21.fw(241), 1\57107_22.fw(241), 1\57107_6.fw(816) Version 1.4.0.0: ID: TDYD-7656 Incorrectly configured modules were not identified on the X2Xbus in certaincircumstances. A dynamic hardware configuration is used for various customer applications.In this case, a default configuration is simply created in AS and the actual configuration is read out after the system has started up. Due to a hardware change of several I/O modules, only a cyclic size of 12 bytes (previously 31 bytes) is accepted in the bootloader. If a module with more cyclic data (e.g. a safety module) is now configured, this modulecan no longer be identified on the bus. As a workaround, these "large" modules can be configured on other X2X slots. This problem can only be corrected with a new bootloader, which can onlybe delivered via production. Production will be switched to the new software accordingly. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57107_21.fw(240), 1\57107_22.fw(240), 1\57107_6.fw(816) Version 1.3.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.2.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: 464170 General adaptions in hardware files Adaptions to maintain hardwarefiles of X20 and X20c modules more easily Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\57107_6.fw(816) Version 1.0.3.0: ID: 459840 Adaption for AS4 - AutoConnect changed to X20BM01 - Accessory X20BM05 added to documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57107_6.fw(816) Version 1.0.0.0: ID: 309815 Support X20cPS3300 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57107_6.fw(816) |
|||||
| Wersja | Język | System operacyjny | Data | Rozmiar | Typ | Pobierz |
| 1.5.0.1 | * | 18/08/2026 | 658 KB | EXE | AS6_HW_X20cPS3300.exe | |
| Opis |
V6.0 HW Upgrade (X20cPS3300) Revision information X20cPS3300 Version 1.5.0.1: ID: QCAS-3535 CVE-2025-43715: Installer is vulnerable to local privilege escalation The installation system NSIS used by B&R can allow local attackers toescalate their privileges. CVE-2025-43715, CVSS: 8.1 (High) CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H Channel description changed: no Configuration description changed: yes Firmwarechanged: no Version 1.5.0.0: ID: TDYD-9096 The current limit values have been standardized on the HW variants. The warning LED isactivated from 1.5 A. From 2.3 A, the error bit and the error LED are set. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57107_21.fw(241), 1\57107_22.fw(241), 1\57107_6.fw(816) Version 1.4.0.0: ID: TDYD-7656 Incorrectly configured modules were not identified on the X2X bus in certain circumstances. A dynamic hardware configuration is used for various customer applications.In this case, a default configuration is simply created inAS and the actual configuration is read out after the system has started up. Due to a hardware change of several I/O modules, only a cyclic size of 12 bytes (previously 31 bytes) is accepted in the bootloader. If a module with more cyclic data (e.g. a safety module) is now configured, this module can no longerbe identified on thebus. As a workaround, these "large" modules can be configured on other X2X slots. This problem can only be corrected with a new bootloader, which can only be delivered via production. Production will be switched to the new software accordingly. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57107_21.fw(240), 1\57107_22.fw(240), 1\57107_6.fw(816) Version 1.3.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.2.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: 464170 General adaptions in hardware files Adaptions to maintain hardwarefiles of X20 and X20c modules more easily Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\57107_6.fw(816) Version 1.0.3.0: ID: 459840 Adaption for AS4 - AutoConnect changed to X20BM01 - Accessory X20BM05 added to documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57107_6.fw(816) Version 1.0.0.0: ID: 309815 Support X20cPS3300 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57107_6.fw(816) |
|||||
| Wersja | Język | System operacyjny | Data | Rozmiar | Typ | Pobierz |
| 1.5.0.0 | * | 30/07/2025 | 954 KB | EXE | AS6_HW_X20cPS3300.exe | |
| Opis |
V6.0 HW Upgrade (X20cPS3300) Revision information X20cPS3300 Version 1.5.0.0: ID: TDYD-9096 The current limit values have been standardized on the HW variants. The warning LED is activated from 1.5 A. From 2.3 A, the error bit and the error LED are set. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57107_21.fw(241), 1\57107_22.fw(241), 1\57107_6.fw(816) Version 1.4.0.0: ID: TDYD-7656 Incorrectly configured modules were not identified on the X2X bus in certain circumstances. A dynamic hardware configuration is used for various customer applications.Inthis case, a default configuration is simply created in AS and the actual configuration is read out after the system has started up. Due to a hardware change of several I/O modules, only a cyclic size of 12 bytes (previously 31 bytes) is accepted in the bootloader. If a module with more cyclic data (e.g. a safety module) is now configured, this module can no longer be identified on the bus. As a workaround, these "large" modules can be configured on other X2X slots. This problem can only be corrected with a new bootloader, which can onlybe delivered via production. Production will be switched to the new software accordingly. Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\57107_21.fw(240), 1\57107_22.fw(240), 1\57107_6.fw(816) Version 1.3.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.2.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: 464170 Generaladaptions in hardware files Adaptions to maintain hardwarefiles of X20 and X20c modules more easily Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\57107_6.fw(816) Version 1.0.3.0: ID: 459840 Adaption for AS4 - AutoConnect changed to X20BM01 - Accessory X20BM05 added to documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57107_6.fw(816) Version 1.0.0.0: ID: 309815 Support X20cPS3300 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57107_6.fw(816) |
|||||
| Wersja | Język | System operacyjny | Data | Rozmiar | Typ | Pobierz |
| 1.4.0.0 | * | 20/01/2025 | 926 KB | EXE | AS6_HW_X20cPS3300.exe | |
| Opis |
V6.0 HW Upgrade (X20cPS3300) Revision information X20cPS3300 Version 1.4.0.0: ID: TDYD-7656 Incorrectly configured modules werenot identified on the X2X bus in certaincircumstances. A dynamic hardware configuration is used for various customer applications.In this case, a default configuration is simply created in AS and the actual configuration is read out after the system has started up. Due to a hardware change of several I/O modules, only a cyclic size of 12 bytes (previously 31 bytes) is accepted inthe bootloader. If a module with more cyclic data (e.g. a safety module) is now configured, this module can no longer be identified on the bus. As a workaround, these "large" modules can be configured on other X2X slots. This problemcan only be corrected with a new bootloader, which can only be delivered via production. Production will be switched to the new software accordingly. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57107_21.fw(240), 1\57107_22.fw(240),1\57107_6.fw(816) Version 1.3.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configurationdescription changed: yes Firmware changed: no Version 1.2.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: 464170 General adaptions in hardware files Adaptions to maintain hardwarefiles of X20 and X20c modules more easily Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\57107_6.fw(816) Version 1.0.3.0: ID: 459840 Adaption for AS4 - AutoConnect changed to X20BM01 - Accessory X20BM05 added to documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57107_6.fw(816) Version 1.0.0.0: ID: 309815 Support X20cPS3300 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57107_6.fw(816) |
|||||