1.5.0.1 * 06/10/2026 893 Ko EXE AS6_HW_X20AI4632.exe
Description V6.0 HW Upgrade (X20AI4632)

Revision information X20AI4632

Version 1.5.0.1:

ID:
Firmware signature enables automatic verification of the authenticity on the target system
The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source.
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.5.0.0:

ID: TDYD-12871
Adjustment of synchronization monitoring
Synchronization Monitoring Revised (applies to modules≥ Rev. I0)
The synchronization monitoring has been optimized. At large X2Xcycle times (starting at approx. 4000 μs), false triggers of the "SyncStatus"data point (redLED) occurred. This issue had no impact on the accuracy of the analog input values, but only affected the error detection of the synchronization status.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9), 1\7073_3.fw(104)

Version 1.4.0.1:

ID: QCAS-3535
CVE-2025-43715: Installer is vulnerable to local privilege escalation
The installation system NSIS used by B&R can allow local attackers toescalatetheir privileges.
CVE-2025-43715, CVSS: 8.1 (High) CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.4.0.0:

ID: TDYD-1274
Support new hardware variant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9), 1\7073_3.fw(103)

Version 1.3.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.2.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.1.7.0:

ID: 645710
Module documentation revised
Data sheet V3.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.6.0:

ID: 583865
Module documentation revised
Data sheet V3.05
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.4.0:

ID: 522105
Module documentation revised
Data sheet V3.02
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.3.0:

ID: 425410
Missing information in documentation included
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 446290
Correction technical data
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.2.1:

ID: 211515
Adjustment SGC section
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.2.0:

ID: 193700
Enhancement comparator for Tracetriggercondition
Enhancement comparator for Tracetriggercondition
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.1.0:

ID: 172225
X20AI4632 no longer works when max. number of samples is set.
If theX20AI4632 module is used to record a trace and special trace settingsare used, the module stops working, and ModuleOk changes to FALSE.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.0.0:

ID: 166035
New FW V5 and HWC V1.1.0.0.
Addition synchronous mode, correction 50 µsec sample time
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(5)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.5.0.0 * 29/09/2026 880 Ko EXE AS6_HW_X20AI4632.exe
Description V6.0 HW Upgrade (X20AI4632)

Revision information X20AI4632

Version 1.5.0.0:

ID: TDYD-12871
Adjustment of synchronization monitoring
Synchronization Monitoring Revised (applies to modules ≥ Rev. I0)
The synchronization monitoring has been optimized. At large X2X cycle times (starting at approx. 4000 μs), false triggers of the "SyncStatus" data point (red LED) occurred. This issue had no impact on the accuracy of the analog inputvalues, but only affected the error detection of the synchronization status.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9), 1\7073_3.fw(104)

Version 1.4.0.1:

ID: QCAS-3535
CVE-2025-43715: Installer is vulnerable to local privilege escalation
The installation system NSIS used by B&R can allow local attackers toescalate their privileges.
CVE-2025-43715, CVSS: 8.1 (High) CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.4.0.0:

ID: TDYD-1274
Support new hardware variant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9), 1\7073_3.fw(103)

Version 1.3.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmwarechanged: no

Version 1.2.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.1.7.0:

ID: 645710
Module documentation revised
Data sheet V3.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.6.0:

ID: 583865
Module documentation revised
Data sheetV3.05
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.4.0:

ID: 522105
Module documentation revised
Data sheet V3.02
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.3.0:

ID: 425410
Missing information in documentation included
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID:446290
Correction technical data
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.2.1:

ID: 211515
Adjustment SGC section
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.2.0:

ID: 193700
Enhancement comparator for Tracetriggercondition
Enhancement comparator for Tracetriggercondition
Channel description changed: Yes
Configurationdescription changed: Yes
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.1.0:

ID: 172225
X20AI4632no longer works when max. number of samples is set.
If the X20AI4632 module is used to record a trace and special trace settings are used, the module stops working, and ModuleOk changes to FALSE.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.0.0:

ID:166035
New FW V5 and HWC V1.1.0.0.
Addition synchronous mode, correction 50 µsec sample time
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(5)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.4.0.1 * 18/08/2026 881 Ko EXE AS6_HW_X20AI4632.exe
Description V6.0 HW Upgrade (X20AI4632)

Revision information X20AI4632

Version 1.4.0.1:

ID: QCAS-3535
CVE-2025-43715: Installer is vulnerable to local privilege escalation
The installation system NSIS used by B&Rcan allow local attackers to escalate their privileges.
CVE-2025-43715, CVSS: 8.1 (High) CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.4.0.0:

ID: TDYD-1274
Support new hardware variant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9), 1\7073_3.fw(103)

Version 1.3.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.2.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.1.7.0:

ID: 645710
Module documentation revised
Data sheet V3.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.6.0:

ID: 583865
Module documentation revised
Data sheet V3.05
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.4.0:

ID: 522105
Module documentation revised
Data sheet V3.02
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.3.0:

ID: 425410
Missing information in documentation included
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 446290
Correction technical data
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.2.1:

ID: 211515
Adjustment SGC section
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.2.0:

ID: 193700
Enhancement comparator for Tracetriggercondition
Enhancement comparator for Tracetriggercondition
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.1.0:

ID: 172225
X20AI4632 no longer works when max.number of samples is set.
If the X20AI4632 module is used to record a trace and special trace settings are used, the module stops working, and ModuleOk changes to FALSE.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9),1\7073_2.fw(9)

Version 1.1.0.0:

ID: 166035
New FW V5 andHWC V1.1.0.0.
Addition synchronous mode, correction 50 µsec sample time
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(5)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.4.0.0 * 21/08/2025 1 Mo EXE AS6_HW_X20AI4632.exe
Description V6.0 HW Upgrade (X20AI4632)

Revision information X20AI4632

Version 1.4.0.0:

ID: TDYD-1274
Support new hardware variant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9), 1\7073_3.fw(103)

Version 1.3.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.2.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.1.7.0:

ID: 645710
Module documentation revised
Data sheet V3.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.6.0:

ID: 583865
Module documentation revised
Data sheet V3.05
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.4.0:

ID: 522105
Module documentation revised
Data sheet V3.02
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.3.0:

ID: 425410
Missing information in documentation included
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 446290
Correction technical data
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.2.1:

ID: 211515
Adjustment SGC section
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.2.0:

ID: 193700
Enhancement comparator for Tracetriggercondition
Enhancement comparator for Tracetriggercondition
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed:No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.1.0:

ID: 172225
X20AI4632 no longer works when max. number of samples is set.
If the X20AI4632 module is used to record a trace and special trace settings are used, the module stops working, and ModuleOk changes to FALSE.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(9), 1\7073_2.fw(9)

Version 1.1.0.0:

ID: 166035
New FW V5 and HWC V1.1.0.0.
Addition synchronous mode, correction 50 µsec sample time
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7073_1.fw(5)