Short description
| Bus controller | POWERLINK (V1/V2) controlled node with up to 2 slots for interface modules |
General information
| Diagnostics | |
| Module status | Yes, using LED status indicator and software |
| Bus function | Yes, using LED status indicator and software |
| Support | |
| Dynamic node allocation (DNA) | Yes |
| Power consumption | |
| Bus | 2 W |
| Certifications | |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
| UL |
cULus E115267 Industrial control equipment |
| HazLoc |
cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| DNV |
Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
| CCS | Yes |
| LR | ENV1 |
| KR | Yes |
| ABS | Yes |
| BV |
EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck |
| KC | Yes |
| B&R ID code | 0x2268 |
| Status indicators | Module status, bus function |
| Additional power dissipation caused by actuators (resistive) [W] | - |
Interfaces
Electrical properties
| Electrical isolation | POWERLINK isolated from bus and I/O |
Operating conditions
| Mounting orientation | |
| Horizontal | Yes |
| Vertical | Yes |
| Installation elevation above sea level | |
| 0 to 2000 m | No limitation |
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature | |
| Operation | |
| Horizontal mounting orientation | -25 to 60°C |
| Vertical mounting orientation | -25 to 50°C |
| Derating | - |
| Storage | -40 to 85°C |
| Transport | -40 to 85°C |
| Relative humidity | |
| Operation | 5 to 95%, non-condensing |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
Materiálové číslo:
X20BC1083Popis:
- POWERLINK
- I/O configuration and firmware update via the fieldbus
- Integrated hub for efficient cabling
- Up to 2 slots for interface modules
The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler.
POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org.
The bus modules expanded to the left allow connection of up to 2 interface modules in addition to the bus controller.
Povinné příslušenství
System modules for bus controllers
| X20PS9400 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
| X20PS9402 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
System modules for expandable bus controllers
| X20BB81 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
| X20BB82 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
Terminal blocks
| X20TB12 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
Volitelné příslušenství
System modules for expandable bus controllers
| X20IF1091-1 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
X20 interface module communication
| X20IF1041-1 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
| X20IF1043-1 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
| X20IF1051-1 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
| X20IF1053-1 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
| X20IF1061-1 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
| X20IF1063-1 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
| X20IF10A1-1 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
| X20IF10D1-1 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
| X20IF10D3-1 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
| X20IF10E1-1 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
| X20IF10E3-1 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
| X20IF10G1-1 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
| X20IF10G3-1 | X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports expansion with X20 interface modules, 2x RJ45, order bus base, power supply module and terminal block separately! |
| Automation Studio HW Upgrades | Verze (datum) | Ke stažení |
|---|---|---|
| V2.6 HW Upgrade (X20BC1083) | EXE / 2 MB | |
| V3.0 HW Upgrade (X20BC1083) | EXE / 2 MB | |
| V4.0 HW Upgrade (X20BC1083) | EXE / 2 MB | |
| V6.0 HW Upgrade (X20BC1083) | EXE / 2 MB |
| Dokumentace | Verze (datum) | Ke stažení |
|---|---|---|
| Data sheet X20(c)BC1083 | PDF / 1 MB | |
| POWERLINK Bus Controller User's Manual | PDF / 3 MB | |
| X20 Package leaflet ATEX/CSA | PDF / 2 MB | |
| X20 System User´s Manual | PDF / 49 MB |
| E-CAD (Electro or EPLAN Templates) | Verze (datum) | Ke stažení |
|---|---|---|
| X20 EPLAN P8 from V2.4 | EXE / 160 MB |
| M-CAD (Mechan. Templates) | Verze (datum) | Ke stažení |
|---|---|---|
| 3D File STEP/DXF X20BC and X20IF Module | ZIP / 1 MB |