3.0.2.0 * 15.12.2025 508 KB EXE AS6_HW_X20SC0402.exe
Popis V6.0 HW Upgrade (X20SC0402)

Revision information X20SC0402

Version 3.0.2.0:

ID: FUVI-12000
Improved bootup behavior
Fixed stability issues; faster bootup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59384_1.fw(652)

Version 3.0.1.0:

ID: FUVI-11882
10µs test pulse for HS/HS outputs corrected
10µs test pulse for HS/HS outputs corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59384_1.fw(651)

Version 3.0.0.0:

ID: FUVI-11178
Control of the outputs reworked
Control of the outputs reworked
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: FUVI-11177
New data sheet V3.0.0
New data sheet V3.0.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: FUVI-11176
First official release for Safety+
First official release for Safety+
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59384_1.fw(650)

Version 2.6.1.0:

ID: QCAS-240
Test pulse generation and evaluation process corrected
The time sequence for test pulse generation and evaluation has been revised. Channels are acknowledged simultaneously after a short circuit, there is no discrepancy error.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59384_1.fw(581)

Version 2.6.0.0:

ID: 780135
Correction of the input filter with set "Filter off".
Correction of the input filter, if a "Filter off" is set and a channel error is detected.
Channel description changed: No
Configurationdescription changed: No
Firmware changed: Yes

ID: 780225
New data sheet V2.20
For changes see chapter "Version history" in the datasheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 780380
Configuration forPower Calculation available
The Configuration for Power Calculation is now available in Automation Studio
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware:10\59384_1.fw(580)

Version 2.4.0.0:

ID: 715230
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data"
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes

ID: 720345
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 726315
The power calculation of the modules is supported
The data for the power calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59384_1.fw(574)

Version 2.3.1.0:

ID: 703240
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 706310
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time and slot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59384_1.fw(573)

Version2.3.0.0:

ID: 692340
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 692380
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 696550
New data sheet V2.07
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59384_1.fw(572)

Version 2.2.0.1:

ID: 668540
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688710
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689695
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689890
Increased delay of external feedback error detection
Increased delay of external feedbackerror detection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689925
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689995
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes

ID: 690070
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59384_1.fw(571)

Version 2.1.0.0:

ID: 568710
Acknowledge several Channel errors with one ReleaseOutput edge.
Several channel error of different types(HSHS, HSLS) are acknowledged with only one ReleaseOutput edge.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 596890
cleared statement in help about open circuit detection
cleared statement in help that the module has no open circuit detection
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 644155
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\59384_1.fw(570)

Version 1.10.9.1:

ID: 643135
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(330)

Version 1.10.9.0:

ID: 618210
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59384_1.fw(330)

Version 1.10.1.0:

ID: 516610
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 539150
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 541650
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 549925
Provide CRC of the Firmware
Provide CRCof the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 570155
Increasethe tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(325)

Version 1.10.0.6:

ID: 532880
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532885
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532890
UpdateECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59384_1.fw(322)

Version 1.10.0.3:

ID: 473000
Improved stability
The stability of the module was improved
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes
Firmware: 1\59384_1.fw(322)

Version 1.10.0.2:

ID: 473375
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(320)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
3.0.1.0 * 09.10.2025 808 KB EXE AS6_HW_X20SC0402.exe
Popis V6.0 HW Upgrade (X20SC0402)

Revision information X20SC0402

Version 3.0.1.0:

ID: FUVI-11882
10µs test pulse for HS/HS outputs corrected
10µs test pulse for HS/HS outputs corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59384_1.fw(651)

Version 3.0.0.0:

ID:FUVI-11178
Control of the outputs reworked
Control of the outputs reworked
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: FUVI-11177
New data sheet V3.0.0
New data sheet V3.0.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: FUVI-11176
First official release for Safety+
First official releasefor Safety+
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59384_1.fw(650)

Version 2.6.1.0:

ID: QCAS-240
Test pulse generation and evaluation process corrected
The time sequence for test pulse generation and evaluation has been revised. Channels are acknowledged simultaneously after a short circuit, there is no discrepancy error.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59384_1.fw(581)

Version 2.6.0.0:

ID: 780135
Correction of the input filter with set "Filter off".
Correction of theinput filter, if a "Filter off" is set and a channel erroris detected.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 780225
New data sheet V2.20
Forchanges see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 780380
Configuration for Power Calculation available
The Configuration for Power Calculation is now available in Automation Studio
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 10\59384_1.fw(580)

Version 2.4.0.0:

ID: 715230
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 720345
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: No

ID: 726315
The power calculation of the modules is supported
The data for the power calculation ofthe data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59384_1.fw(574)

Version 2.3.1.0:

ID: 703240
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 706310
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time and slot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59384_1.fw(573)

Version 2.3.0.0:

ID: 692340
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 692380
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes

ID: 696550
New data sheet V2.07
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59384_1.fw(572)

Version 2.2.0.1:

ID: 668540
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688710
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689695
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689890
Increased delay of external feedback error detection
Increased delay of external feedback error detection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689925
Improvement of the internal voltagemonitoring.
Improvement of the internal voltage monitoring.
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689995
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690070
New data sheet V2.06
For changes seechapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59384_1.fw(571)

Version 2.1.0.0:

ID: 568710
Acknowledge several Channel errors with one ReleaseOutput edge.
Several channel error of different types(HSHS, HSLS) are acknowledged with only one ReleaseOutput edge.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 596890
cleared statement in help about open circuit detection
cleared statement in help that the module has no open circuit detection
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 644155
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\59384_1.fw(570)

Version 1.10.9.1:

ID: 643135
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(330)

Version 1.10.9.0:

ID: 618210
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59384_1.fw(330)

Version 1.10.1.0:

ID: 516610
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 539150
Adaptfilter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 541650
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 549925
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 570155
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(325)

Version 1.10.0.6:

ID: 532880
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532885
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532890
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59384_1.fw(322)

Version 1.10.0.3:

ID: 473000
Improved stability
The stability of the module was improved
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59384_1.fw(322)

Version 1.10.0.2:

ID: 473375
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(320)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
3.0.0.0 * 25.07.2025 808 KB EXE AS6_HW_X20SC0402.exe
Popis V6.0 HW Upgrade (X20SC0402)

Revision information X20SC0402

Version 3.0.0.0:

ID: FUVI-11178
Control of the outputs reworked
Control of the outputs reworked
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: FUVI-11177
New data sheet V3.0.0
New data sheet V3.0.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: FUVI-11176
First official release for Safety+
First official release for Safety+
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56733_1.fw(650)

Version 2.6.1.0:

ID: QCAS-240
Test pulse generation and evaluation process corrected
The time sequence for test pulse generation and evaluation has been revised. Channels are acknowledged simultaneously after a short circuit, there is no discrepancy error.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\56733_1.fw(581)

Version 2.6.0.0:

ID: 780125
Correction of the input filter with set "Filter off".
Correction of the input filter, if a "Filter off" is set and a channelerroris detected.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 780250
New data sheet V2.20
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 780370
Configuration for Power Calculation available
The Configuration for Power Calculation is nowavailable in Automation Studio
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 10\56733_1.fw(580)

Version 2.4.0.0:

ID: 719725
Failsafe at every boot
It could happen under rare conditions that the module is stuckin failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849"Received crc data is not equal to sent crc data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 726580
The power calculation of the modules is supported
The data for the power calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 727105
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56733_1.fw(574)

Version 2.3.0.1:

ID: 692330
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 692370
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 696540
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 706285
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time andslot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\56733_1.fw(573)

Version 2.2.0.0:

ID: 670590
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688680
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689685
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689885
Increased delay of external feedback error detection
Increased delay of external feedback error detection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689915
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689990
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690060
New data sheet V2.06
For changes see chapter "Versionhistory" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56733_1.fw(571)

Version 2.1.0.0:

ID: 644275
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\56733_1.fw(570)

Version 1.10.10.0:

ID: 622785
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(331)

Version 1.10.9.1:

ID: 643440
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed:No
Configuration description changed: No
Firmware changed: No
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(330)

Version 1.10.9.0:

ID: 618175
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(330)

Version 1.10.1.2:

ID: 549935
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 552675
Loggerentry on negativ edge of SafeModuleOK
If a negativ edge on SafeModuleOK is detected, a logger entry will be generated
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 553735
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(326)

Version 1.10.0.6:

ID: 533020
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 533105
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(320)

Version 1.10.0.1:

ID: 474325
Support of release 1.10 including openSAFETY 1.5
Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 474330
changed manual verion to 1.100
changed manual verion to 1.100
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 5\56733_1.fw(301), 6\56733_1.fw(320)

Version 1.9.1.1:

ID: 453175
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed:Yes
Firmware: 5\56733_1.fw(301)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.6.1.0 * 04.03.2025 3 MB EXE AS6_HW_X20SC0402.exe
Popis V6.0 HW Upgrade (X20SC0402)

Revision information X20SC0402

Version 2.6.1.0:

ID: QCAS-240
Test pulse generation and evaluation process corrected
The time sequence for test pulse generation and evaluation has been revised. Channels are acknowledged simultaneously after a short circuit, there is no discrepancy error.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59384_1.fw(581)

Version 2.6.0.0:

ID: 780135
Correction of the input filter with set "Filter off".
Correction of the input filter, if a "Filter off" is set and a channel error is detected.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 780225
New data sheet V2.20
For changessee chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 780380
Configuration for Power Calculation available
The Configuration for Power Calculation is now available in Automation Studio
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 10\59384_1.fw(580)

Version 2.4.0.0:

ID: 715230
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot,generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 720345
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 726315
The power calculation of the modules is supported
The data for the power calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59384_1.fw(574)

Version 2.3.1.0:

ID: 703240
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 706310
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring ofmodule cycle time andslot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59384_1.fw(573)

Version 2.3.0.0:

ID: 692340
Support of the DYNlink interface
The DYNlink interface is supported by thesafe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 692380
The OSDD signal at the pulse output is corrected.
The OSDD signal at the pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 696550
New data sheet V2.07
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59384_1.fw(572)

Version 2.2.0.1:

ID: 668540
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688710
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689695
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689890
Increased delay of external feedback error detection
Increased delay of external feedback error detection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689925
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689995
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis of the output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690070
New data sheet V2.06
For changes see chapter"Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59384_1.fw(571)

Version 2.1.0.0:

ID: 568710
Acknowledge several Channel errors with one ReleaseOutput edge.
Several channel error of different types(HSHS, HSLS) are acknowledged with only one ReleaseOutput edge.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 596890
cleared statement in help about open circuit detection
cleared statement in help that the module has no open circuit detection
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 644155
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\59384_1.fw(570)

Version 1.10.9.1:

ID: 643135
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmwarechanged: No
Firmware: 1\59384_1.fw(330)

Version 1.10.9.0:

ID: 618210
logger entry 112174, 108078
Logger entry 112174, 108078could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59384_1.fw(330)

Version 1.10.1.0:

ID: 516610
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed: Yes
Configuration descriptionchanged: No
Firmware changed: Yes

ID: 539150
Adapt filter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configurationdescription changed: No
Firmware changed: Yes

ID: 541650
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 549925
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 570155
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(325)

Version 1.10.0.6:

ID: 532880
Add blackout mode
Addblackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532885
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532890
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59384_1.fw(322)

Version 1.10.0.3:

ID: 473000
Improved stability
The stability of the module was improved
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59384_1.fw(322)

Version 1.10.0.2:

ID: 473375
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(320)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.6.0.0 * 05.03.2024 3 MB EXE AS6_HW_X20SC0402.exe
Popis V6.0 HW Upgrade (X20SC0402)

Revision information X20SC0402

Version 2.6.0.0:

ID: 780135
Correction of the input filter with set "Filter off".
Correction of the input filter, if a "Filter off" is set and a channel error is detected.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 780225
New data sheet V2.20
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 780380 / Support ID: 400412437
Configuration for Power Calculation available
The Configuration for Power Calculation is now available in Automation Studio
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 10\59384_1.fw(580)

Version 2.4.0.0:

ID: 715230
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 720345
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 726315
The power calculation of the modules is supported
The data for the power calculation of the data sheet isincluded in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59384_1.fw(574)

Version 2.3.1.0:

ID: 703240
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 706310
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time and slot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\59384_1.fw(573)

Version 2.3.0.0:

ID: 692340
Support of the DYNlink interface
The DYNlink interface is supported by the safe inputs.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 692380 / Support ID: 400311305
The OSDD signal at the pulse output is corrected.
The OSDD signal atthe pulse output is output correctly even when not in use.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 696550
New data sheet V2.07
For changes see chapter "Version history" in the data sheet.
Channel description changed:No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59384_1.fw(572)

Version 2.2.0.1:

ID: 668540
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID:688710 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689695
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689890
Increased delay of external feedback error detection
Increased delay of external feedback error detection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689925
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689995
Improvement of the feedback diagnosis.
Improvement of the feedback diagnosis ofthe output.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690070
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\59384_1.fw(571)

Version 2.1.0.0:

ID: 568710
Acknowledge several Channel errors with one ReleaseOutput edge.
Several channel error of different types(HSHS, HSLS) areacknowledged with only one ReleaseOutput edge.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 596890 / Support ID: 400253825
cleared statement in help about open circuit detection
cleared statement in help that the module has noopen circuit detection
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 644155
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\59384_1.fw(570)

Version 1.10.9.1:

ID: 643135
data sheetV1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(330)

Version 1.10.9.0:

ID: 618210
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59384_1.fw(330)

Version 1.10.1.0:

ID: 516610 / Support ID: 400203957
add PhysicalStateChannels on X20SLX842
add PhysicalStateChannels on X20SLX842.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes

ID: 539150
Adaptfilter algorithm to eliminate dependencies between TON and TOF-filter
Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 541650
New default values
The default values for "Filter On" and "Discrepancy Time" have been modified
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 549925
Provide CRC of the Firmware
Provide CRC of the Firmware
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 570155
Increase the tolerance of the voltage monitor
The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(325)

Version 1.10.0.6:

ID: 532880
Add blackout mode
Add blackout mode
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532885
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 532890
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59384_1.fw(322)

Version 1.10.0.3:

ID: 473000
Improved stability
The stability of the module was improved
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59384_1.fw(322)

Version 1.10.0.2:

ID: 473375
first official release
first official release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59384_1.fw(320)
Loading
Zpět k seznamu

Vyberte prosím zemi a jazyk

B&R Logo