1.8.1.0 * 19.03.2024 3 MB EXE AS6_HW_X20CP3685.exe
Popis V6.0 HW Upgrade (X20CP3685)

Revision information X20CP3685

Version 1.8.1.0:

ID: 783330
Ethernet timer cycles down to 400µsec possible
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\63982_0.pci(12), 1\63982_1.pci(12), 1\63982a0.epl(142), 1\63982a1.epl(142)

Version 1.8.0.0:

ID: 772230 / Support ID: 400400350, 400406359, 400407650
Wrong powerconsumption data corrected: calculated values in AS did not match to correct documentation
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\63982_0.pci(12), 1\63982_1.pci(12), 1\63982a0.epl(142), 1\63982a1.epl(142)

Version 1.7.2.0:

ID: 753445
Support PTP: changed parameters
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\63982_0.pci(12), 1\63982_1.pci(12), 1\63982a0.epl(142), 1\63982a1.epl(142)

Version 1.7.1.0:

ID: 741620
Support PTP: Ethernet interface timer as system timer
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\63982_0.pci(12), 1\63982_1.pci(12), 1\63982a0.epl(142), 1\63982a1.epl(142)

Version 1.5.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.4.0.0:

ID: 707550 / Support ID: 400337456, 400335994, 400331585, 400337790, 400343808, 400344614
X20CPx68xxx POWERLINK IF3: Input data is transferred incorrectly.
With the onboard POWERLINK interface of the X20CPx68xxx, it couldhappen that input data was transferred incorrectly.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 715845 / Support ID: 400303836
Extended diagnostic for miminal latency input stations
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 715975
Module documentation revised
Data sheet V1.03
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\63982_0.pci(12), 1\63982_1.pci(12), 1\63982a0.epl(142), 1\63982a1.epl(142)

Version 1.1.0.0:

ID: 694725
Support data point StorageWear, wear level of storage medium starting fromAR A4.90
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 694840
Module documentation revised
Data sheet V 1.02
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 694965
Support for automatic DNA configuration from AS 4.9.1
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\63982_0.pci(9), 1\63982a0.epl(141)

Version 1.0.1.0:

ID: 645905
Support X20CP3685
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\63982_0.pci(9), 1\63982a0.epl(141)