DWL@DWL10000284075

Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.1.1.0 * 01.12.2016 553 KB EXE AS4_HW_5AC901.BX05-02.exe
Popis V4.0 HW Upgrade (5AC901.BX05-02)

Revision information 5AC901.BX05-02

Version 1.1.1.0:

ID: 500065
Adeption of the PCIe interface
Depending on the interface it is possible to plug x1, x4 and x8 PCIe devices in the module 5AC901.BX05-02.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 500085
The module is classified as BusUnit
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 500150
The module is now shown correctly in the system designer
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.1.0.1:

ID: 375400
Classification adapted for support in Automation Studio AS 4.1.x
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.1.0.0:

ID: 373525
Correction of the arrangement of PCI and PCIexpress slots
The PCI and PCIexpress slots were arranged in wrong order in Automation Studio.
This has been corrected.The arrangement now matches the description in the user manual and the label on the system.

Attention: This upgrade creates an incompatibility at systems, which run and work! In this case it is NOT recommended, to install this upgrade!
Is the the described correction nevertheless necessary, the appropriate PCI card in the field of "Unoconnected Hardware Modules" in Automation Studio must be re-connected after installing this upgrade.
Furthermore,the node number on the PCI card, if available, has to be adjustedaccordingly.
Channel description changed: No
Configuration description changed:Yes
Firmware changed: No

Version 1.0.0.0:

ID: 336455
Support for 5AC901.BX05-02
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes