DWL@DWL10000062193

Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.1.1.0 * 16.03.2016 1 MB EXE AS3.0_HW_X20PS2110.exe
Popis V3.0 HW Upgrade (X20PS2110)

Revision information X20PS2110

Version 1.1.1.0:

ID: 471015
Module documentation revised
Data sheet V3.20
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: No
Firmware: 1\8214_5.fw(784), 1\8214_6.fw(784), 1\8214_7.fw(817)

Version 1.1.0.0:

ID: 463985
General adaptions in hardware files
Adaptions to maintain hardwarefiles of X20 and X20c modules more easily
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 464095
Currently produced Firmware added
Firmware for HW variant 7 published in AS
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\8214_5.fw(784), 1\8214_6.fw(784), 1\8214_7.fw(817)

Version 1.0.4.0:

ID: 456485
Documentation update in reference to standards
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 459430
Adaption for AS4
- AutoConnect changed to X20BM01
- Accessory X20BM05 added to documentation
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\8214_5.fw(784), 1\8214_6.fw(784), 1\8214_7.fw(800)

Version 1.0.3.0:

ID: 260530 / Support ID: 400061307
Error correction in channel description
Adverse settings in the AS I/O configuration maycause an error on X2X
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\8214_5.fw(784), 1\8214_6.fw(784), 1\8214_7.fw(800)

Version 1.0.2.0:

ID:227890
Extension in IO-Mapping for SG3 CanIO
Datapoint for Bus voltage added
Channel description changed: Yes
Configuration descriptionchanged: No
Firmware changed: No
Firmware: 1\8214_5.fw(784), 1\8214_6.fw(784), 1\8214_7.fw(800)

Version 1.0.1.1:

ID: 176385
Correction HWC display of data point "SupplyVoltage" on Powerlink-BC
Correction HWC display of data point "SupplyVoltage" on Powerlink-BC
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\8214_5.fw(784), 1\8214_6.fw(784), 1\8214_7.fw(800)

Version 1.0.0.1:

ID: 166175
New FW V800 and HWC V1.0.0.1
New diagnostic data fuse status
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\8214_5.fw(784), 1\8214_6.fw(784), 1\8214_7.fw(800)
Loading
Zpět k seznamu

Vyberte prosím zemi a jazyk

B&R Logo