General information
System requirements
Automation Studio 4.3.3 or later
Automation Runtime B4.34 or later
mapp Technology Package mapp Services
Single-user license Runtime license
Basic package license 1TGMPDB.20-01
Behavior if license missing License violation indicated by red blinking LED
Malzeme numarası:
1TGMPDB.20-01
Açıklama:
  • Communicate with the database without having to deal with SQL database language
  • Start queries via easy-to-operate configuration interface

mapp Database enables the simple integration of SQL databases into an application. It does not matter whether the database is located on a PC on the machine or whether the data is collected centrally in the company network.

Tipik uygulamalar:
  • Saving a machine's production data to a database
  • Performing quality checks based on the information in the database
  • Operating machines with production and machine parameters from a database
Fonksiyonel kapsam:

When setting up mapp Database, the user defines the connection parameters to the database in the configuration, for example the port number or IP address of the database. Queries can then be defined that can be used at runtime to create tables or add, delete and adjust entries. The user can create the queries via a simplified configuration interface and therefore does not need any SQL knowledge. Alternatively, it is possible to work directly with SQL queries.

Zorunlu aksesuarlar
Technology Guard
1TGMPSRV.00-01 Basic license for mapp Services Required to use extended functions of the mapp Technology Package. This license includes mapp AlarmX (alarm management), mapp IO (dynamic hardware configuration), mapp User (user management), mapp Alarm (alarm management with reference to VC4), mapp File (file explorer), mapp Skyline (visualization of a machine line in combination with a mapp View widget), mapp J1939 (SAE J1939 protocol) and mapp Recipe (recipe management).
İsteğe bağlı aksesuarlar
Other functions
X20cCMR011 X20 cabinet monitoring module, coated, integrated temperature sensor, moisture sensor and accelerometer, production data acquisition, 2 inputs for external Pt1000, 2 digital inputs 24 V, 1 digital output 24 V, 0.5 A, 512 kB flash memory for user data
X20CMR011 X20 cabinet monitoring module, integrated temperature sensor, moisture sensor and accelerometer, production data acquisition, 2 inputs for external PT1000, 2 digital inputs 24 V, 1 digital output 24 V, 0.5 A, 512 kB flash memory for user data
X20CMR100 X20 cabinet monitoring module, integrated temperature and humidity sensor, production data acquisition, integrated Technology Guard
X20CMR111 X20 cabinet monitoring module, integrated temperature sensor, moisture sensor and accelerometer, production data acquisition, 2 inputs for external Pt1000, 2 digital inputs 24 V, 1 digital output 24 V, 0.5 A, 512 kB flash memory for user data, integrated Technology Guard
Technology Guard
0TG1000.01 Technology Guard (MSD)
0TG1000.02 Technology Guard (HID)
0TGF016.01 Technology Guard (MSD) with integrated flash drive, 16 GB (MLC)
Automation Studio yardım yükseltmeleri Sürüm (Tarih) İndirme
mapp Database: Connecting to a database PDF / 2 MB

Lütfen ülke ve dil seçin

B&R Logo