DWL@DWL10000827702
| Sürüm | Dil | İşletim sistemi | Tarih | Boyut | Tip | İndirme |
|---|---|---|---|---|---|---|
| 3.1.0.2 | * | 10/07/2026 | 530 KB | EXE | AS6_HW_X20ST4492.exe | |
| Açıklama |
V6.0 HW Upgrade (X20ST4492) Revision information X20ST4492 Version 3.1.0.2: ID: Firmware signature enables automatic verification of the authenticity on the target system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source. Channel description changed: no Configuration description changed: yes Firmware changed: no Version 3.1.0.1: ID: FUVI-12963 SafetyPlus Public Release Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\46105_1.fw(574) Version 3.0.0.0: ID: FUVI-11177 New data sheet V3.0.0 New data sheet V3.0.0 Channel description changed: No Configuration description changed: No Firmware changed: No ID: FUVI-11176 First official release for Safety+ First official release for Safety+ Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\46105_1.fw(574) Version 2.5.0.0: ID: 720250 Improved stability of FW during internal hardware tests Improved stability of FW during internal hardware tests Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\46105_1.fw(574) Version 2.4.0.0: ID: 719750 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 726640 The power calculation of the modules is supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727150 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\46105_1.fw(573) Version 2.3.0.0: ID: 714555 Handling of ADC-Tests adjusted Handling of ADC-Tests if DisableShuntTest=Yes is adjusted. Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 714575 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of modulecycle time andslot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 714590 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\46105_1.fw(572) Version 2.2.0.0: ID: 613330 Changes in mappSafety firmware Bug was fixed with the firmware changes for mappSafety. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 668615 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688765 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689715 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689950 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690095 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\46105_1.fw(571) Version 2.1.0.0: ID: 568660 Documentation of test case sequence corrected Bug in documentation of test case sequence was corrected Channel description changed: No Configuration description changed: No Firmware changed: No ID: 644175 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\46105_1.fw(570) Version 1.10.10.0: ID: 622665 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(331) Version 1.10.9.1: ID: 643235 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330) Version 1.10.9.0: ID: 618285 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330) Version 1.10.1.5: ID: 585625 User configurable calculation of the input value during internal tests alsoin AS 3.x User configurable calculation of the input value during internal tests alsoin AS 3.x Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 585630 SafeThrSelector_0506_Bitx not working - Fix in AS 3.x The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always thefirst thresholds are used. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.1.1: ID: 533055 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533145 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533195 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: No Firmware changed: No ID: 536305 SafeThrSelector_0506_Bitx not working The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 539130 User configurable calculation of the input value during internal tests User configurable calculation of the input value during internal tests Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.0.1: ID: 470650 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470655 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(321) Version 1.9.0.0: ID: 404205 safety response time The safety response time is now depending on the configured filter. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302) Version 1.7.0.1: ID: 388465 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.7.0.0: ID: 372070 changed manual verion to 1.70 changed manual verion to 1.70 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.6.0.98: ID: 370680 Violation of cycle time in PreOp with input filter 1ms Functions were rearranged in PreOp to comply with the cycle time for all filters. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 370690 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8. SafetyRelease 1.8 serves as basis for the backward compatibility Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(311) Version 1.6.0.7: ID: 339295 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.5: ID: 335505 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335510 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.3: ID: 332250 The module also supportsSafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.2: ID: 328595 Correction for responsetimecalculator Correction of parameters used for the calculation of the worstcase responsetime in Release 1.6 with the responsetimecalculator. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.1: ID: 314585 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.5: ID: 312420 added pindefinitions for EPLAN export added pindefinitions for EPLAN export Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.4: ID: 303410 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.0: ID: 293960 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) |
|||||
| Sürüm | Dil | İşletim sistemi | Tarih | Boyut | Tip | İndirme |
| 3.1.0.1 | * | 06/18/2026 | 526 KB | EXE | AS6_HW_X20ST4492.exe | |
| Açıklama |
V6.0 HW Upgrade (X20ST4492) Revision information X20ST4492 Version 3.1.0.1: ID: FUVI-12963 SafetyPlus Public Release Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\56735_1.fw(574) Version 3.0.0.0: ID: FUVI-11177 New data sheet V3.0.0 New data sheet V3.0.0 Channel description changed: No Configuration description changed: No Firmware changed: No ID: FUVI-11176 First official releasefor Safety+ First official release for Safety+ Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56735_1.fw(574) Version 2.5.0.0: ID: 720240 Improved stability of FW during internal hardware tests Improved stability of FW during internal hardware tests Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\56735_1.fw(574) Version 2.4.0.0: ID: 719720 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 726575 The power calculation of the modulesis supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727100 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed:No Firmware changed: No Firmware: 10\56735_1.fw(573) Version2.3.0.0: ID: 714545 LED status corrected Channel LED's arecorrected and it fits to dokumentation. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 714550 Handling of ADC-Tests adjusted Handling of ADC-Tests if DisableShuntTest=Yes is adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 714565 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 714580 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56735_1.fw(572) Version 2.2.0.0: ID: 670585 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688675 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689680 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689910 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690055 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56735_1.fw(571) Version 2.1.0.0: ID: 644170 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\56735_1.fw(570) Version 1.10.10.0: ID: 622655 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 6\56735_1.fw(331) Version 1.10.9.1: ID: 643230 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 6\56735_1.fw(330) Version 1.10.9.0: ID: 615205 Correction of the internal Vref measurement Internal Vref measurement adapted for the extended temperature range Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 618170 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\56735_1.fw(330) Version 1.10.1.1: ID: 542645 User configurable calculation of the input value during internal tests User configurable calculation of the input value during internal tests Channel description changed: No Configuration description changed: No Firmware changed: No ID: 542650 Increased input range The input range is extended to 500uA to 25mA. Channel description changed: No Configuration description changed: No Firmwarechanged: No ID: 542655 selected thresholds are transmited via acyclic registers selected thresholds are transmited via acyclic registers Channel description changed: No Configuration description changed: No Firmware changed: No ID: 542665 New channel for ConnectionValid New channel for ConnectionValid Channel description changed:No Configuration description changed: No Firmware changed: No ID: 542670 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 6\56735_1.fw(322) Version 1.10.0.2: ID: 485070 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 6\56735_1.fw(321) |
|||||
| Sürüm | Dil | İşletim sistemi | Tarih | Boyut | Tip | İndirme |
| 3.0.0.0 | * | 08/06/2025 | 826 KB | EXE | AS6_HW_X20ST4492.exe | |
| Açıklama |
V6.0 HW Upgrade (X20ST4492) Revision information X20ST4492 Version 3.0.0.0: ID: FUVI-11177 New data sheet V3.0.0 New data sheet V3.0.0 Channel description changed: No Configuration description changed: No Firmware changed: No ID: FUVI-11176 First official release for Safety+ First official release for Safety+ Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\46105_1.fw(574) Version 2.5.0.0: ID: 720250 Improved stability of FW during internal hardware tests Improved stability of FW during internal hardware tests Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\46105_1.fw(574) Version 2.4.0.0: ID: 719750 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 726640 The power calculation of the modules is supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727150 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\46105_1.fw(573) Version 2.3.0.0: ID: 714555 Handling of ADC-Tests adjusted Handling of ADC-Tests if DisableShuntTest=Yes is adjusted. Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 714575 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of modulecycle time andslot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 714590 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\46105_1.fw(572) Version 2.2.0.0: ID: 613330 Changes in mappSafety firmware Bug was fixed with the firmware changes for mappSafety. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 668615 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688765 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689715 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689950 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690095 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\46105_1.fw(571) Version 2.1.0.0: ID: 568660 Documentation of test case sequence corrected Bug in documentation of test case sequence was corrected Channel description changed: No Configuration description changed: No Firmware changed: No ID: 644175 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\46105_1.fw(570) Version 1.10.10.0: ID: 622665 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(331) Version 1.10.9.1: ID: 643235 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330) Version 1.10.9.0: ID: 618285 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330) Version 1.10.1.5: ID: 585625 User configurable calculation of the input value during internal tests alsoin AS 3.x User configurable calculation of the input value during internal tests alsoin AS 3.x Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 585630 SafeThrSelector_0506_Bitx not working - Fix in AS 3.x The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always thefirst thresholds are used. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.1.1: ID: 533055 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533145 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533195 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: No Firmware changed: No ID: 536305 SafeThrSelector_0506_Bitx not working The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 539130 User configurable calculation of the input value during internal tests User configurable calculation of the input value during internal tests Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.0.1: ID: 470650 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470655 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(321) Version 1.9.0.0: ID: 404205 safety response time The safety response time is now depending on the configured filter. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302) Version 1.7.0.1: ID: 388465 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.7.0.0: ID: 372070 changed manual verion to 1.70 changed manual verion to 1.70 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.6.0.98: ID: 370680 Violation of cycle time in PreOp with input filter 1ms Functions were rearranged in PreOp to comply with the cycle time for all filters. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 370690 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8. SafetyRelease 1.8 serves as basis for the backward compatibility Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(311) Version 1.6.0.7: ID: 339295 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.5: ID: 335505 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335510 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.3: ID: 332250 The module also supportsSafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.2: ID: 328595 Correction for responsetimecalculator Correction of parameters used for the calculation of the worstcase responsetime in Release 1.6 with the responsetimecalculator. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.1: ID: 314585 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.5: ID: 312420 added pindefinitions for EPLAN export added pindefinitions for EPLAN export Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.4: ID: 303410 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.0: ID: 293960 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) |
|||||
| Sürüm | Dil | İşletim sistemi | Tarih | Boyut | Tip | İndirme |
| 2.5.0.0 | * | 10/06/2026 | 526 KB | EXE | AS6_HW_X20ST4492.exe | |
| Açıklama |
V6.0 HW Upgrade (X20ST4492) Revision information X20ST4492 Version 2.5.0.0: ID: 720250 Improved stability of FW during internal hardware tests Improved stability of FW during internal hardware tests Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\46105_1.fw(574) Version 2.4.0.0: ID: 719750 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 726640 The power calculation of the modules is supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727150 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\46105_1.fw(573) Version 2.3.0.0: ID: 714555 Handling of ADC-Tests adjusted Handling of ADC-Tests if DisableShuntTest=Yes is adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 714575 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 714590 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\46105_1.fw(572) Version 2.2.0.0: ID: 613330 / Support ID: 400263334 Changes in mappSafety firmware Bug was fixed with the firmware changes for mappSafety. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 668615 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688765 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689715 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689950 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690095 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\46105_1.fw(571) Version 2.1.0.0: ID: 568660 / Support ID: 400247281 Documentation of test case sequence corrected Bug in documentation of test case sequence was corrected Channel description changed: No Configuration description changed: No Firmware changed: No ID: 644175 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\46105_1.fw(570) Version 1.10.10.0: ID: 622665 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(331) Version 1.10.9.1: ID: 643235 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330) Version 1.10.9.0: ID: 618285 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330) Version 1.10.1.5: ID: 585625 User configurable calculation of the input value during internal tests also in AS 3.x User configurable calculation of the input value during internal tests also in AS 3.x Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 585630 SafeThrSelector_0506_Bitx not working - Fix in AS 3.x The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.1.1: ID: 533055 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533145 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: No Configuration description changed: No Firmware changed: No ID: 533195 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: No Firmware changed: No ID: 536305 SafeThrSelector_0506_Bitx not working The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 539130 User configurable calculation of the input value during internal tests User configurable calculation of the input value during internal tests Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322) Version 1.10.0.1: ID: 470650 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470655 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(321) Version 1.9.0.0: ID: 404205 safety response time The safety response time is now depending on the configured filter. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302) Version 1.7.0.1: ID: 388465 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.7.0.0: ID: 372070 changed manual verion to 1.70 changed manual verion to 1.70 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301) Version 1.6.0.98: ID: 370680 / Support ID: 400107215 Violation of cycle time in PreOp with input filter 1ms Functions were rearranged in PreOp to comply with the cycle time for all filters. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 370690 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8. SafetyRelease 1.8 serves as basis for the backward compatibility Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(311) Version 1.6.0.7: ID: 339295 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.5: ID: 335505 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335510 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.3: ID: 332250 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.2: ID: 328595 Correction for responsetimecalculator Correction of parameters used for the calculation of the worstcase responsetime in Release 1.6 with the responsetimecalculator. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.6.0.1: ID: 314585 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.5: ID: 312420 added pindefinitions for EPLAN export added pindefinitions for EPLAN export Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.4: ID: 303410 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) Version 1.5.0.0: ID: 293960 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\46105_1.fw(295) |
|||||