DWL@DWL10000827702

Versión Idioma
Sistema operativo
Fecha
Tamaño
Tipo Descargar
3.1.0.2 * 07.10.2026 530 KB EXE AS6_HW_X20ST4492.exe
Descripción V6.0 HW Upgrade (X20ST4492)

Revision information X20ST4492

Version 3.1.0.2:

ID:
Firmware signature enables automatic verification of the authenticity on the target system
The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source.
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 3.1.0.1:

ID: FUVI-12963
SafetyPlus Public Release
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 10\46105_1.fw(574)

Version 3.0.0.0:

ID: FUVI-11177
New data sheet V3.0.0
New data sheet V3.0.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: FUVI-11176
First official release for Safety+
First official release for Safety+
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\46105_1.fw(574)

Version 2.5.0.0:

ID: 720250
Improved stability of FW during internal hardware tests
Improved stability of FW during internal hardware tests
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\46105_1.fw(574)

Version 2.4.0.0:

ID: 719750
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data"
Channel description changed: No
Configuration description changed:No
Firmware changed: Yes

ID: 726640
The power calculation of the modules is supported
The data for the power calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 727150
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\46105_1.fw(573)

Version 2.3.0.0:

ID: 714555
Handling of ADC-Tests adjusted
Handling of ADC-Tests if DisableShuntTest=Yes is adjusted.
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 714575
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of modulecycle time andslot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 714590
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\46105_1.fw(572)

Version 2.2.0.0:

ID: 613330
Changes in mappSafety firmware
Bug was fixed with the firmware changes for mappSafety.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 668615
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688765
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689715
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689950
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690095
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\46105_1.fw(571)

Version 2.1.0.0:

ID: 568660
Documentation of test case sequence corrected
Bug in documentation of test case sequence was corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 644175
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\46105_1.fw(570)

Version 1.10.10.0:

ID: 622665
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(331)

Version 1.10.9.1:

ID: 643235
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330)

Version 1.10.9.0:

ID: 618285
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330)

Version 1.10.1.5:

ID: 585625
User configurable calculation of the input value during internal tests alsoin AS 3.x
User configurable calculation of the input value during internal tests alsoin AS 3.x
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 585630
SafeThrSelector_0506_Bitx not working - Fix in AS 3.x
The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always thefirst thresholds are used.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322)

Version 1.10.1.1:

ID: 533055
Add blackout mode
Add blackout mode
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 533145
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 533195
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 536305
SafeThrSelector_0506_Bitx not working
The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 539130
User configurable calculation of the input value during internal tests
User configurable calculation of the input value during internal tests
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322)

Version 1.10.0.1:

ID: 470650
changed manual verion to 1.100
changed manual verion to 1.100
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 470655
Support of release 1.10 including openSAFETY 1.5
Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(321)

Version 1.9.0.0:

ID: 404205
safety response time
The safety response time is now depending on the configured filter.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302)

Version 1.7.0.1:

ID: 388465
internal Adjustments
internal Adjustments
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301)

Version 1.7.0.0:

ID: 372070
changed manual verion to 1.70
changed manual verion to 1.70
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301)

Version 1.6.0.98:

ID: 370680
Violation of cycle time in PreOp with input filter 1ms
Functions were rearranged in PreOp to comply with the cycle time for all filters.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 370690
The module also supports SafetyRelease 1.8
Starting with this version, the module also supports SafetyRelease 1.8. SafetyRelease 1.8 serves as basis for the backward compatibility
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(311)

Version 1.6.0.7:

ID: 339295
internal Adjustments
internal Adjustments
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.6.0.5:

ID: 335505
The module also supports SafetyRelease 1.7
Starting with this version, the module also supports SafetyRelease 1.7
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 335510
unlock of SafeModule IDs > 300
SafeModule IDs up to 1023 are now unlocked
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.6.0.3:

ID: 332250
The module also supportsSafetyRelease 1.7
Starting with this version, the module also supports SafetyRelease 1.7
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.6.0.2:

ID: 328595
Correction for responsetimecalculator
Correction of parameters used for the calculation of the worstcase responsetime in Release 1.6 with the responsetimecalculator.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.6.0.1:

ID: 314585
Adaption of module configuration file release 1.6
Adaption of module configuration file release 1.6
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.5.0.5:

ID: 312420
added pindefinitions for EPLAN export
added pindefinitions for EPLAN export
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.5.0.4:

ID: 303410
Support of AutomationStudio 4.0
Support of AutomationStudio 4.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.5.0.0:

ID: 293960
First Official Release
First Official Release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)
Versión Idioma
Sistema operativo
Fecha
Tamaño
Tipo Descargar
3.1.0.1 * 18.06.2026 526 KB EXE AS6_HW_X20ST4492.exe
Descripción V6.0 HW Upgrade (X20ST4492)

Revision information X20ST4492

Version 3.1.0.1:

ID: FUVI-12963
SafetyPlus Public Release
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 10\56735_1.fw(574)

Version 3.0.0.0:

ID: FUVI-11177
New data sheet V3.0.0
New data sheet V3.0.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: FUVI-11176
First official releasefor Safety+
First official release for Safety+
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56735_1.fw(574)

Version 2.5.0.0:

ID: 720240
Improved stability of FW during internal hardware tests
Improved stability of FW during internal hardware tests
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\56735_1.fw(574)

Version 2.4.0.0:

ID: 719720
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data"
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 726575
The power calculation of the modulesis supported
The data for the power calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 727100
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed:No
Firmware changed: No
Firmware: 10\56735_1.fw(573)

Version2.3.0.0:

ID: 714545
LED status corrected
Channel LED's arecorrected and it fits to dokumentation.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 714550
Handling of ADC-Tests adjusted
Handling of ADC-Tests if DisableShuntTest=Yes is adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 714565
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time and slot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 714580
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56735_1.fw(572)

Version 2.2.0.0:

ID: 670585
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688675
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689680
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689910
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690055
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\56735_1.fw(571)

Version 2.1.0.0:

ID: 644170
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\56735_1.fw(570)

Version 1.10.10.0:

ID: 622655
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes
Firmware: 6\56735_1.fw(331)

Version 1.10.9.1:

ID: 643230
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 6\56735_1.fw(330)

Version 1.10.9.0:

ID: 615205
Correction of the internal Vref measurement
Internal Vref measurement adapted for the extended temperature range
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 618170
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 6\56735_1.fw(330)

Version 1.10.1.1:

ID: 542645
User configurable calculation of the input value during internal tests
User configurable calculation of the input value during internal tests
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 542650
Increased input range
The input range is extended to 500uA to 25mA.
Channel description changed: No
Configuration description changed: No
Firmwarechanged: No

ID: 542655
selected thresholds are transmited via acyclic registers
selected thresholds are transmited via acyclic registers
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 542665
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed:No
Configuration description changed: No
Firmware changed: No

ID: 542670
Add blackout mode
Add blackout mode
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 6\56735_1.fw(322)

Version 1.10.0.2:

ID: 485070
first official release
first official release
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 6\56735_1.fw(321)
Versión Idioma
Sistema operativo
Fecha
Tamaño
Tipo Descargar
3.0.0.0 * 06.08.2025 826 KB EXE AS6_HW_X20ST4492.exe
Descripción V6.0 HW Upgrade (X20ST4492)

Revision information X20ST4492

Version 3.0.0.0:

ID: FUVI-11177
New data sheet V3.0.0
New data sheet V3.0.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: FUVI-11176
First official release for Safety+
First official release for Safety+
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\46105_1.fw(574)

Version 2.5.0.0:

ID: 720250
Improved stability of FW during internal hardware tests
Improved stability of FW during internal hardware tests
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\46105_1.fw(574)

Version 2.4.0.0:

ID: 719750
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data"
Channel description changed: No
Configuration description changed:No
Firmware changed: Yes

ID: 726640
The power calculation of the modules is supported
The data for the power calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 727150
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\46105_1.fw(573)

Version 2.3.0.0:

ID: 714555
Handling of ADC-Tests adjusted
Handling of ADC-Tests if DisableShuntTest=Yes is adjusted.
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 714575
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of modulecycle time andslot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 714590
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\46105_1.fw(572)

Version 2.2.0.0:

ID: 613330
Changes in mappSafety firmware
Bug was fixed with the firmware changes for mappSafety.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 668615
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688765
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689715
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689950
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690095
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\46105_1.fw(571)

Version 2.1.0.0:

ID: 568660
Documentation of test case sequence corrected
Bug in documentation of test case sequence was corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 644175
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\46105_1.fw(570)

Version 1.10.10.0:

ID: 622665
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(331)

Version 1.10.9.1:

ID: 643235
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330)

Version 1.10.9.0:

ID: 618285
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330)

Version 1.10.1.5:

ID: 585625
User configurable calculation of the input value during internal tests alsoin AS 3.x
User configurable calculation of the input value during internal tests alsoin AS 3.x
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 585630
SafeThrSelector_0506_Bitx not working - Fix in AS 3.x
The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always thefirst thresholds are used.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322)

Version 1.10.1.1:

ID: 533055
Add blackout mode
Add blackout mode
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 533145
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 533195
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 536305
SafeThrSelector_0506_Bitx not working
The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 539130
User configurable calculation of the input value during internal tests
User configurable calculation of the input value during internal tests
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322)

Version 1.10.0.1:

ID: 470650
changed manual verion to 1.100
changed manual verion to 1.100
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 470655
Support of release 1.10 including openSAFETY 1.5
Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(321)

Version 1.9.0.0:

ID: 404205
safety response time
The safety response time is now depending on the configured filter.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302)

Version 1.7.0.1:

ID: 388465
internal Adjustments
internal Adjustments
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301)

Version 1.7.0.0:

ID: 372070
changed manual verion to 1.70
changed manual verion to 1.70
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301)

Version 1.6.0.98:

ID: 370680
Violation of cycle time in PreOp with input filter 1ms
Functions were rearranged in PreOp to comply with the cycle time for all filters.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 370690
The module also supports SafetyRelease 1.8
Starting with this version, the module also supports SafetyRelease 1.8. SafetyRelease 1.8 serves as basis for the backward compatibility
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(311)

Version 1.6.0.7:

ID: 339295
internal Adjustments
internal Adjustments
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.6.0.5:

ID: 335505
The module also supports SafetyRelease 1.7
Starting with this version, the module also supports SafetyRelease 1.7
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 335510
unlock of SafeModule IDs > 300
SafeModule IDs up to 1023 are now unlocked
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.6.0.3:

ID: 332250
The module also supportsSafetyRelease 1.7
Starting with this version, the module also supports SafetyRelease 1.7
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.6.0.2:

ID: 328595
Correction for responsetimecalculator
Correction of parameters used for the calculation of the worstcase responsetime in Release 1.6 with the responsetimecalculator.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.6.0.1:

ID: 314585
Adaption of module configuration file release 1.6
Adaption of module configuration file release 1.6
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.5.0.5:

ID: 312420
added pindefinitions for EPLAN export
added pindefinitions for EPLAN export
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.5.0.4:

ID: 303410
Support of AutomationStudio 4.0
Support of AutomationStudio 4.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.5.0.0:

ID: 293960
First Official Release
First Official Release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)
Versión Idioma
Sistema operativo
Fecha
Tamaño
Tipo Descargar
2.5.0.0 * 06.10.2026 526 KB EXE AS6_HW_X20ST4492.exe
Descripción V6.0 HW Upgrade (X20ST4492)

Revision information X20ST4492

Version 2.5.0.0:

ID: 720250
Improved stability of FW during internal hardware tests
Improved stability of FW during internal hardware tests
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 10\46105_1.fw(574)

Version 2.4.0.0:

ID: 719750
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 726640
The power calculation of the modules is supported
The data for the power calculation of the data sheet is included in the HWX.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 727150
New data sheet V2.10
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\46105_1.fw(573)

Version 2.3.0.0:

ID: 714555
Handling of ADC-Tests adjusted
Handling of ADC-Tests if DisableShuntTest=Yes is adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 714575
Limit values for the module cycle time adjusted
The limit values for the calculation and monitoring of module cycle time and slot time adjusted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 714590
New data sheet V2.08
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\46105_1.fw(572)

Version 2.2.0.0:

ID: 613330 / Support ID: 400263334
Changes in mappSafety firmware
Bug was fixed with the firmware changes for mappSafety.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 668615
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 688765 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689715
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 689950
Improvement of the internal voltage monitoring.
Improvement of the internal voltage monitoring.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 690095
New data sheet V2.06
For changes see chapter "Version history" in the data sheet.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 10\46105_1.fw(571)

Version 2.1.0.0:

ID: 568660 / Support ID: 400247281
Documentation of test case sequence corrected
Bug in documentation of test case sequence was corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 644175
major (even incompatible) changes for mapp Safety
First upgrade for mapp Safety.
ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help!
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 10\46105_1.fw(570)

Version 1.10.10.0:

ID: 622665
Sporadic errors 114982, 102914, 120065, 110385
Sporadic errors 114982, 102914, 120065, 110385 have been fixed
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(331)

Version 1.10.9.1:

ID: 643235
data sheet V1.141
See chapture "Version history" in the data sheet.
i.a. calculation of Safety response time has been updated.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330)

Version 1.10.9.0:

ID: 618285
logger entry 112174, 108078
Logger entry 112174, 108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(330)

Version 1.10.1.5:

ID: 585625
User configurable calculation of the input value during internal tests also in AS 3.x
User configurable calculation of the input value during internal tests also in AS 3.x
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 585630
SafeThrSelector_0506_Bitx not working - Fix in AS 3.x
The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322)

Version 1.10.1.1:

ID: 533055
Add blackout mode
Add blackout mode
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 533145
New channel for ConnectionValid
New channel for ConnectionValid
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 533195
Update ECAD data
Update ECAD data
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 536305
SafeThrSelector_0506_Bitx not working
The selection of the thresholds to use for channel 5 and 6 by SafeThrSelector_0506_Bitx is not working. Subsequently always the first thresholds are used.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 539130
User configurable calculation of the input value during internal tests
User configurable calculation of the input value during internal tests
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(322)

Version 1.10.0.1:

ID: 470650
changed manual verion to 1.100
changed manual verion to 1.100
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 470655
Support of release 1.10 including openSAFETY 1.5
Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302), 6\46105_1.fw(321)

Version 1.9.0.0:

ID: 404205
safety response time
The safety response time is now depending on the configured filter.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(302)

Version 1.7.0.1:

ID: 388465
internal Adjustments
internal Adjustments
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301)

Version 1.7.0.0:

ID: 372070
changed manual verion to 1.70
changed manual verion to 1.70
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301)

Version 1.6.0.98:

ID: 370680 / Support ID: 400107215
Violation of cycle time in PreOp with input filter 1ms
Functions were rearranged in PreOp to comply with the cycle time for all filters.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 370690
The module also supports SafetyRelease 1.8
Starting with this version, the module also supports SafetyRelease 1.8. SafetyRelease 1.8 serves as basis for the backward compatibility
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 3\46105_1.fw(295), 4\46105_1.fw(301), 5\46105_1.fw(311)

Version 1.6.0.7:

ID: 339295
internal Adjustments
internal Adjustments
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.6.0.5:

ID: 335505
The module also supports SafetyRelease 1.7
Starting with this version, the module also supports SafetyRelease 1.7
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 335510 / Support ID: 400083263
unlock of SafeModule IDs > 300
SafeModule IDs up to 1023 are now unlocked
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.6.0.3:

ID: 332250
The module also supports SafetyRelease 1.7
Starting with this version, the module also supports SafetyRelease 1.7
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.6.0.2:

ID: 328595
Correction for responsetimecalculator
Correction of parameters used for the calculation of the worstcase responsetime in Release 1.6 with the responsetimecalculator.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.6.0.1:

ID: 314585
Adaption of module configuration file release 1.6
Adaption of module configuration file release 1.6
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.5.0.5:

ID: 312420
added pindefinitions for EPLAN export
added pindefinitions for EPLAN export
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.5.0.4:

ID: 303410
Support of AutomationStudio 4.0
Support of AutomationStudio 4.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)

Version 1.5.0.0:

ID: 293960
First Official Release
First Official Release
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 3\46105_1.fw(295)
Loading
Volver al listado

Seleccione país e idioma

B&R Logo