DWL@DWL10000878277
| Sürüm | Dil | İşletim sistemi | Tarih | Boyut | Tip | İndirme |
|---|---|---|---|---|---|---|
| 1.7.1.1 | * | 10/07/2026 | 2 MB | EXE | AS6_HW_X20IF10D1-1.exe | |
| Açıklama |
V6.0 HW Upgrade (X20IF10D1-1) Revision information X20IF10D1-1 Version 1.7.1.1: ID: Firmware signature enables automatic verification of the authenticity on the target system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installedfirmware is unchanged and comes from a trusted source. Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.7.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration descriptionchanged: yes Firmware changed: no Version 1.6.0.0: ID: 483025 Module documentation revised Data sheet V1.22 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 627900 Replacement of the interfacecard in AS "Replace HW Modul" works correktly Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 666300 IO mapping of the configured EtherNet/IP adapter is shown correctly. IO mapping of the configured EtherNet/IP adapter is shown correctly. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42779a1.fw(32), 1\42779_1.fw(13) Version 1.5.0.0: ID: 644055 New Firmware Problem with "unconnected message handling" was fixed. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42779a1.fw(30), 1\42779_1.fw(13) Version 1.4.0.0: ID: 598095 New Firmware Problem with "unconnected message handling" was fixed. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42779a1.fw(29), 1\42779_1.fw(13) Version 1.3.1.0: ID: 469100 netX configuration module name can be defined for X20IF10D1-1 in AS 4 at SGC CPU Channeldescription changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42779a1.fw(27), 1\42779_1.fw(12) Version 1.3.0.0: ID: 396810 EthernetIP master(X20IF10D1-1) only controls 12 slaves Error fixed in Hilscher FW version 2.8.0.0 Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 465630 insert ModulOK Insert ModulOK fromAR4.25 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 465635 FDT/DTM Cycle Time change Change parameter name "Cycle time [µs]" to "Data exchange time (CPU-netX) [µs]" Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42779a1.fw(26),1\42779_1.fw(12) Version 1.2.1.0: ID: 357120 Dynamic configuration The name of the generated netX module can be freely assigned in order to enable a dynamic configuration of netX modules in AR. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42779a1.fw(18), 1\42779_1.fw(12) Version 1.2.0.0: ID: 283615 New firmware: ODVA certification Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42779a1.fw(18), 1\42779_1.fw(12) Version 1.1.1.0: ID: 268245 Input data of Ethernet/IP slaves is no longer being transferred Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42779a1.fw(17), 1\42779_1.fw(12) Version 1.1.0.0: ID: 257440 Vendor ID changed Module notifies now with the B&R Vendor ID Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42779a1.fw(15), 1\42779_1.fw(12) Version 1.0.1.0: ID: 239190 Interface module EtherNet/IP Scanner, first version Interface module EtherNet/IP Scanner, first version Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\42779a1.fw(13), 1\42779_1.fw(12) |
|||||