DWL@DWL10000878049
| Wersja | Język | System operacyjny | Data | Rozmiar | Typ | Pobierz |
|---|---|---|---|---|---|---|
| 1.5.1.1 | * | 06/10/2026 | 3 MB | EXE | AS6_HW_X20cAP3121.exe | |
| Opis |
V6.0 HW Upgrade (X20cAP3121) Revision information X20cAP3121 Version 1.5.1.1: ID: Firmware signature enables automatic verification of the authenticity on the target system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source. Channel descriptionchanged: no Configuration description changed: yes Firmware changed: no Version 1.5.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.0.0: ID: 693390 Error correction losing stored energy values Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 693480 Module documentation revised Data sheet 2.56 Channel description changed: No Configuration description changed:No Firmware changed: No Firmware: 1\57876_3.fw(94), 1\57876_5.fw(330) Version 1.3.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.2.0.0: ID: 651445 Error correction losing stored energy values Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 651515 Module documentation revised Data sheet V2.53 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57876_3.fw(94), 1\57876_5.fw(310) Version 1.1.4.0: ID: 610265 HWX-file correction Double indication of the configuration at AS.4.1 is corrected. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 610275 HWX-file correction Indication error of the configuration at AS.4.2 is corrected. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57876_3.fw(94), 1\57876_5.fw(300) Version 1.1.3.0: ID: 603060 Module documentation revised Data sheet V2.48 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57876_3.fw(94), 1\57876_5.fw(300) Version 1.1.1.0: ID: 593985 Module documentation revised Data sheet V2.47 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57876_3.fw(94), 1\57876_5.fw(300) Version 1.1.0.0: ID: 585925 Support hw variant 5 New firmware v300 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 585970 Module documentation revised Data sheet V2.45 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57876_3.fw(94), 1\57876_5.fw(300) Version 1.0.6.0: ID: 558980 Module documentation revised Data sheet V2.43 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57876_3.fw(94) Version 1.0.4.0: ID: 526720 Module documentation revised Data sheet V2.40 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57876_3.fw(94) Version1.0.3.0: ID: 484965 module documentation revised data sheet V2.21 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57876_3.fw(94) Version 1.0.1.1: ID: 480895 Unit Wh added in hwx/hwc Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 481674 module documentation revised datasheet V2.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57876_3.fw(94) Version 1.0.0.1: ID: 397020 Correct function of oversampling mode on POWERLINK Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57876_3.fw(94) Version 1.0.0.0: ID: 342380 Support X20cAP3121 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57876_3.fw(94) |
|||||