DWL@DWL10000849330
| Wersja | Język | System operacyjny | Data | Rozmiar | Typ | Pobierz |
|---|---|---|---|---|---|---|
| 1.5.3.0 | * | 18/03/2026 | 6 MB | EXE | AS4_HW_X90CP174.48-00.exe | |
| Opis |
V4.12 HW Upgrade (X90CP174.48-00) Revision information X90CP174.48-00 Version 1.5.3.0: ID: RKFY-11585 Incorrect Description Text for Dither The description text for Dither will be removed. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60223_1.fp(32), 2\60223_1.fp(54) Version 1.5.2.0: ID: 786520 Chapter "Configuration" added to documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60223_1.fp(32), 2\60223_1.fp(54) Version 1.5.0.0: ID: 735200 Error in AB counter mode fixed. When a channel was configured as "Digital input source", the "Counter" Register was not reset to zero after reboot. Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 779250 Operating mode iCN on POWERLINK: spurious connection problem to the managerafter power fail corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\60223_1.fp(32), 2\60223_1.fp(54) Version 1.4.6.0: ID: 762080 X2X bus output cycle trigger error correction The X2X bus output cycle trigger was not started although it was configured. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60223_1.fp(24), 2\60223_1.fp(50) Version 1.4.5.0: ID: 743065 Broadcast channels missing in PLK interface Due to the change to Powerlink type 6, the broadcast channels have to be included. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60223_1.fp(24), 2\60223_1.fp(50) Version 1.4.4.0: ID: 727570 Support for 6 A current on parallel channels When two 6 A channels are used in parallel mode, a total current of 12 A isnow possible. Attention: When using 4 A and 6 A channels in parallel, each channel can only supply 4 A. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 729150 Support for POWERLINK type 6 The module now supports POWERLINK type 6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60223_1.fp(24), 2\60223_1.fp(50) Version 1.4.3.0: ID: 714655 Module documentation revised Data sheet V2.30 Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60223_1.fp(24), 2\60223_1.fp(50) Version 1.4.0.0: ID: 703135 Enables second CPU core for I/O processing The I/O input processing can be assigned to the the second CPU core. This frees CPU processing power to be used by the application. Channel description changed: Yes Configuration description changed: Yes Firmwarechanged: No Firmware: 1\60223_1.fp(24), 2\60223_1.fp(50) Version 1.3.1.0: ID: 694775 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 694900 Support for automatic DNA configuration from AS 4.9.1 Networktype Powerlink added. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60223_1.fp(24), 2\60223_1.fp(50) Version 1.3.0.0: ID: 693010 Enable TFTP server To enable a firmware update for mobile panels, the TFTPServer must be activated. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\60223_1.fp(24), 2\60223_1.fp(50) Version 1.2.4.0: ID: 673445 Description of "Total Current" changed to 0-45 A Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\60223_1.fp(24), 2\60223_1.fp(50) Version 1.2.3.0: ID: 667945 Enhanced CPU Configuration: Loss of remanent data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60223_1.fp(24), 2\60223_1.fp(50) Version 1.2.2.0: ID: 652190 Improved I/O Minimal requirements AS version 4.7.1 and AR 4.71 New functions: Analogue Channels Resistor measurement 0-50 kOhm Temperature measurement PT1000 Current measurement: 4-20 mA Digital Output Channels: Adjustable maximum current 0-4 A PWM Channels: H-Bridge mode Dithering Adjustable maximum current 0-4 A / 0-6 A up to4 kHz in PWM mode, up to 8 kHz im H-brigde mode Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60223_1.fp(24), 2\60223_1.fp(50) Version 1.0.3.0: ID: 588510 Maximum total current added to documentation Channel description changed: No Configuration description changed: No Firmware changed: No ID: 589280 I/O Data "SensorSupply" has been described Channel description changed: No Configuration description changed: No Firmware changed: No ID: 595655 Documentation of analog inputs improved. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 609995 Corrupted CAN messages on IF9 (CAN3) With heavy load on the processor interface a "race condition" may exist on the CAN control for IF9 (CAN3). As a result, the register access and the data access may interfere. For solving this "race condition" a locking mechanism has been added, that allows data access tothe CAN component only after the configuration via register accesses have been finished. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\60223_1.fp(24) Version 1.0.2.0: ID: 573905 Support X90CP174.48-00 Important remark: To use the help, a minimum version 4.3.5.24 of the Automation Studio Main Help is required. Otherwise the upgrade is installed, but the help pages are empty. In case you installed the upgrade in the wrong order, you mustfirst uninstall the Main Help using the Windows Control Panel, installthe Main Help again and then apply the Module Upgrade Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60223_1.fp(23) |
|||||