DWL@DWL10000825093

仕様版 言語
オペレーティングシステム
日付
サイズ
タイプ ダウンロード
3.1.1.1 * 2026/10/07 624 KB EXE AS6_HW_X20SLX806-1.exe
説明 V6.0 HW Upgrade (X20SLX806-1)

Revision information X20SLX806-1

Version 3.1.1.1:

ID:
Firmware signature enables automatic verification of the authenticity on the target system
The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installedfirmware is unchanged and comes from a trusted source.
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 3.1.1.0:

ID: FUVI-14039
download failed with certain projects
Download could fail with certain projects with loggerentry "internal error loading a file".
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: FUVI-13555
CycleTime_utilized
"CycleTime_utilized" provides the correct value now.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: FUVI-13424
Failsafe when using variable watch
With some projects it could have happened that the SLX switched to failsafewhen using SafeDesigner+ variable watch.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 11\12063_1.fw(654)

Version 3.1.0.0:

ID: FUVI-13653
SafetyPlus Public Release
SafetyPlus Public Release
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 11\12063_1.fw(653)

Version 3.0.2.0:

ID: FUVI-11441
improved bootup behaviour
fixed stability issues; faster bootup; no failsafe upon missing user application
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: FUVI-11310
error "Internal error I/O data"
Fixed error "Internal error I/O data" which couldoccour when used with veryhigh X2X cycle time and/or very low application cycle time.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 11\12063_1.fw(652)

Version 3.0.1.0:

ID: FUVI-11882
10µs test pulse for HS/HS outputs corrected
10µs test pulse for HS/HS outputs corrected
Channel description changed: No
Configuration description changed: No
Firmwarechanged: Yes
Firmware: 11\12063_1.fw(651)

Version 3.0.0.0:

ID: FUVI-11571
First official release of SLXxxx-1 for Safety+
First official release of SLXxxx-1 for Safety+
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 11\12063_1.fw(650)
仕様版 言語
オペレーティングシステム
日付
サイズ
タイプ ダウンロード
3.1.1.0 * 2026/09/01 620 KB EXE AS6_HW_X20SLX806-1.exe
説明 V6.0 HW Upgrade (X20SLX806-1)

Revision information X20SLX806-1

Version 3.1.1.0:

ID: FUVI-14039
download failed with certain projects
Download could fail with certain projects with logger entry "internal errorloading a file".
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: FUVI-13555
CycleTime_utilized
"CycleTime_utilized" provides the correct value now.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: FUVI-13424
Failsafe when using variable watch
With some projects it could have happened that the SLX switched to failsafewhen using SafeDesigner+ variable watch.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 11\12063_1.fw(654)

Version 3.1.0.0:

ID: FUVI-13653
SafetyPlus Public Release
SafetyPlus Public Release
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 11\12063_1.fw(653)

Version 3.0.2.0:

ID: FUVI-11441
improved bootup behaviour
fixedstability issues; faster bootup; no failsafe upon missing user application
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: FUVI-11310
error "Internal error I/O data"
Fixed error "Internal error I/O data" which could occour when used with very high X2X cycle time and/or very low application cycle time.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 11\12063_1.fw(652)

Version 3.0.1.0:

ID: FUVI-11882
10µs test pulse for HS/HS outputs corrected
10µs test pulse for HS/HS outputs corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 11\12063_1.fw(651)

Version 3.0.0.0:

ID: FUVI-11571
First official release of SLXxxx-1 for Safety+
First official release of SLXxxx-1 for Safety+
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 11\12063_1.fw(650)
仕様版 言語
オペレーティングシステム
日付
サイズ
タイプ ダウンロード
3.1.0.0 * 2026/06/18 620 KB EXE AS6_HW_X20SLX806-1.exe
説明 V6.0 HW Upgrade (X20SLX806-1)

Revision information X20SLX806-1

Version 3.1.0.0:

ID: FUVI-13653
SafetyPlus Public Release
SafetyPlus Public Release
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 11\12063_1.fw(653)

Version 3.0.2.0:

ID: FUVI-11441
improved bootup behaviour
fixed stability issues; faster bootup; no failsafe upon missing user application
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: FUVI-11310
error "Internal error I/O data"
Fixed error "Internal error I/O data" which could occour when used with very high X2X cycle time and/or very low application cycle time.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 11\12063_1.fw(652)

Version 3.0.1.0:

ID: FUVI-11882
10µs test pulse for HS/HS outputs corrected
10µs test pulse for HS/HS outputs corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 11\12063_1.fw(651)

Version 3.0.0.0:

ID: FUVI-11571
First official release of SLXxxx-1 for Safety+
First official release of SLXxxx-1 for Safety+
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 11\12063_1.fw(650)
仕様版 言語
オペレーティングシステム
日付
サイズ
タイプ ダウンロード
3.0.2.0 * 2025/12/15 620 KB EXE AS6_HW_X20SLX806-1.exe
説明 V6.0 HW Upgrade (X20SLX806-1)

Revision information X20SLX806-1

Version 3.0.2.0:

ID: FUVI-11441
improved bootup behaviour
fixed stability issues; faster bootup; no failsafe upon missing user application
Channel description changed: No
Configuration description changed:No
Firmware changed: Yes

ID: FUVI-11310
error "Internal error I/O data"
Fixed error "Internal error I/O data" which could occour when used with very high X2X cycle time and/or very low application cycle time.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 11\12063_1.fw(652)

Version 3.0.1.0:

ID: FUVI-11882
10µs test pulse for HS/HS outputs corrected
10µs test pulse for HS/HS outputs corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 11\12063_1.fw(651)

Version 3.0.0.0:

ID: FUVI-11571
First official release of SLXxxx-1 for Safety+
First official release of SLXxxx-1 for Safety+
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 11\12063_1.fw(650)
仕様版 言語
オペレーティングシステム
日付
サイズ
タイプ ダウンロード
3.0.1.0 * 2025/10/10 919 KB EXE AS6_HW_X20SLX806-1.exe
説明 V6.0 HW Upgrade (X20SLX806-1)

Revision information X20SLX806-1

Version 3.0.1.0:

ID: FUVI-11882
10µs test pulse for HS/HS outputs corrected
10µs test pulse for HS/HS outputs corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 11\12063_1.fw(651)

Version 3.0.0.0:

ID: FUVI-11571
First official release of SLXxxx-1 for Safety+
Firstofficial release of SLXxxx-1 for Safety+
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 11\12063_1.fw(650)
仕様版 言語
オペレーティングシステム
日付
サイズ
タイプ ダウンロード
3.0.0.0 * 2025/07/04 919 KB EXE AS6_HW_X20SLX806-1.exe
説明 V6.0 HW Upgrade (X20SLX806-1)

Revision information X20SLX806-1

Version 3.0.0.0:

ID: FUVI-11571
First official release of SLXxxx-1 for Safety+
First official release of SLXxxx-1 for Safety+
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 11\12063_1.fw(650)