DWL@DWL10000809705
| 仕様版 | 言語 | オペレーティングシステム | 日付 | サイズ | タイプ | ダウンロード |
|---|---|---|---|---|---|---|
| 1.9.0.0 | * | 2025/01/31 | 828 KB | EXE | AS6_HW_5ACCIF01.FPLK-000.exe | |
| 説明 |
V6.0 HW Upgrade (5ACCIF01.FPLK-000) Revision information 5ACCIF01.FPLK-000 Version 1.9.0.0: ID: AQAJ-8759 New FW version with following changes: - Precautionary fix for sporadic power-up issue due to PCI reset pulse. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59834_0.pci(13), 1\59834a0.epl(143) Version 1.8.0.0: ID: 769725 POWERLINK Manager Type 3 und 4 If a CN with the parameter NMTCNSoC2PReq set was operated in a network withPOWERLINK Manager type 3 and 4, this could lead to the error "20803 POWERLINK: A fatal error has occurred" if network disturbancesoccurred. Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\59834_0.pci(12), 1\59834a0.epl(143) Version 1.7.2.0: ID: 750225 Implemented new IO data points HardwareVariant and FirmwareVersion of the IF option card. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 751645 Configurable module supervision of the xPC2100/xPC2200 IF option The supervision of the xPC2100/xPC2200 IF option can now be configured. In case of a missconfiguration or missing xPC2100/xPC2200 IF option the APC/PPC is starting up in the service mode. This behavior can be configured via the configuration of the supervised option, the default is supervised = on. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59834_0.pci(11), 1\59834a0.epl(142) Version 1.7.1.0: ID: 722475 Extended diagnostic for miminal latency input stations Channel description changed: Yes Configuration description changed: No Firmwarechanged: No ID: 722480 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operated in operating mode "Ethernet" and connected to a POWERLINK network in this mode, the interface could fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 723115 Enhancements for APROL. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 723120 Internal memory management of the POWERLINK IF optimized. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 730660 Starting with AS V4.7.1 503,75kB (515840Byte) nvSRAM are available for configuration in Hypervisor of remanent data. For ARemb the 510,75kB (523008Byte) remain for remanent data. Channel description changed: No Configurationdescription changed: Yes Firmware changed: No Firmware: 1\59834_0.pci(11), 1\59834a0.epl(142) Version 1.6.2.0: ID: 695675 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59834_0.pci(10), 1\59834a0.epl(141) Version 1.6.1.0: ID: 533390 Enhancements for Aprol. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 678760 Optimized cross traffic of the integrated PowerlinkHub starting with AS4.5. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59834_0.pci(10), 1\59834a0.epl(141) Version 1.6.0.0: ID: 672630 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 672635 EPLAN Daten implemented Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59834_0.pci(10), 1\59834a0.epl(141) Version 1.5.0.0: ID: 647505 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 647510 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 647525 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station"it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 647535 Preparation to support theAutomation PC 2200 and the Panel PC 2200 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59834_0.pci(10), 1\59834a0.epl(140) Version 1.4.0.0: ID: 634865 Bugfix in the FPGA firmware The stability of the communication has been optimized for harsh environment. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59834_0.pci(9), 1\59834a0.epl(136) Version 1.3.0.0: ID: 615165 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happenthat no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 615170 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" thatare not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 615175 Firmware optimized for stability Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 617560 Revision of the configuration of RemMem datas in dependency of the ARwin From ARwin version M4.10 or A4.26 on it is possible to configure up to 256kB as remanent datas. Channeldescription changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59834_0.pci(9), 1\59834a0.epl(136) Version 1.2.0.0: ID: 472875 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtimeversions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 479810 Revision of the configuration of RemMem datas in dependency of the AR From ARemb version L4.10 or C4.25 on it is possible to configure up to 256kB as remanent datas. With ARwin it is furthermore possible to use 128kB as RemMem data. Anincrease of the RemMem datas for ARwin is planed for a later version. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 481365 Data transfer errors on POWERLINK-Interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59834_0.pci(7), 1\59834a0.epl(130) Version 1.0.1.0: ID: 470185 New FPGA version V6 nvSRAM bug fix for unaligned memory access. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59834_0.pci(5), 1\59834a0.epl(1649) Version 1.0.0.0: ID: 461750 Support for 5ACCIF01.FPLK-000 The 5ACCIF01.FPLK-000 interface card is supported beginning with AutomationStudio 4.1.9.xand Automation Runtime J4.10. The 5ACCIF01.FPLK-000 interface card is supported beginning with Automation Studio 4.2.5.x and Automation Runtime A4.25. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\59834_0.pci(5), 1\59834a0.epl(1649) |
|||||