DWL@DWL10000878234
| Versione | Lingua | Sistema operativo | Data | Taglia | Tipologia | Download |
|---|---|---|---|---|---|---|
| 1.4.1.1 | * | 07/10/2026 | 806 KB | EXE | AS6_HW_X20DO6529.exe | |
| Descrizione |
V6.0 HW Upgrade (X20DO6529) Revision information X20DO6529 Version 1.4.1.1: ID: Firmware signature enables automatic verification of the authenticity on the target system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source. Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.0.0: ID: 766205 Failure ModulOK If this module starting with revision E0 is operated behind a bus controller, the network status fails every 10 s (for one X2X cycle). This failure has the following effects. - Local X2X bus: No effect - POWERLINK / Modbus TCP / PROFIBUS / CAN I/O: No effect - CANopen: "Object 0x30B2 Network status OK" fails sporadically. - OPC-UA: Flag ModuleOK of the respective X2X module may fail sporadically - EthernetIP / PROFINET / Sercos3 / EtherCAT: - No effect directly on the bus controller. - The network status is transferred asBYTE at the beginning of the cyclic data of the respective X2X station (ModuleOK) and can be evaluated by the respective remote station (data point mappingand evaluation within the application). - Setpoint: 0xF5, in the event of error: 0xF1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8217_30.fw(110), 1\8217_5.fw(800) Version 1.3.0.0: ID: 746815 Support new HW variant 30 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8217_30.fw(100), 1\8217_5.fw(800) Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.2.1: ID: 501655 X2X limit values added No influence on existing projects. Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\8217_5.fw(800) Version 1.0.2.0: ID: 499165 Module documentation revised Data sheet V 3.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8217_5.fw(800) Version 1.0.1.3: ID: 394830 Enhancement online-help files Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8217_5.fw(800) Version 1.0.1.2: ID: 393775 Enhancements packed data point for outputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\8217_5.fw(800) Version 1.0.1.1: ID: 226030 Possibility to set X2X station number in combination with X20BMx5 activated Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8217_5.fw(800) Version 1.0.1.0: ID: 217355 Adaptation UART Re-Init Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8217_5.fw(800) |
|||||