DWL@DWL10000878222
| Versione | Lingua | Sistema operativo | Data | Taglia | Tipologia | Download |
|---|---|---|---|---|---|---|
| 1.4.1.1 | * | 07/10/2026 | 867 KB | EXE | AS6_HW_X20DO4322.exe | |
| Descrizione |
V6.0 HW Upgrade (X20DO4322) Revision information X20DO4322 Version 1.4.1.1: ID: Firmware signature enables automatic verification of the authenticity on the target system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source. Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.0.0: ID: 766220 Failure ModulOK If this module starting with revision G1 is operated behind a bus controller, the network status fails every 10 s (for one X2X cycle). This failure has the following effects. - Local X2X bus: No effect - POWERLINK / Modbus TCP / PROFIBUS / CAN I/O: No effect - CANopen: "Object 0x30B2 Network status OK" fails sporadically. - OPC-UA: Flag ModuleOK of the respective X2X module may fail sporadically - EthernetIP / PROFINET / Sercos3 / EtherCAT: - No effect directly on the bus controller. - The network status is transferred asBYTE at the beginning of the cyclic data of the respective X2X station (ModuleOK) and can be evaluated by the respective remote station (data point mappingand evaluation within the application). - Setpoint: 0xF5, in the event of error: 0xF1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7063_1.fw(560), 1\7063_20.fw(220), 1\7063_5.fw(816) Version 1.3.0.0: ID: 749075 Support new HW variant 20 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7063_1.fw(560), 1\7063_20.fw(210), 1\7063_5.fw(816) Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.3.0: ID: 467155 Module documentation revised Data sheet V 3.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7063_1.fw(560), 1\7063_5.fw(816) Version 1.0.2.4: ID: 393460 Enhancement online-help files Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 1\7063_1.fw(560), 1\7063_5.fw(816) Version 1.0.2.3: ID: 393015 Enhancements packed data point for outputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7063_1.fw(560), 1\7063_5.fw(816) Version 1.0.2.2: ID: 366269 APROL entries revised Datapoint OSPValid corrected Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7063_1.fw(560), 1\7063_5.fw(816) Version 1.0.2.0: ID: 317670 Additional function model "OSP mode" OSP - Output Set Predefined InOSP mode, the user defines the output behavior in case of connection loss between PLC and module. In doing so the power supply of the module must be assured. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7063_1.fw(560), 1\7063_5.fw(816) Version 1.0.1.0: ID: 217455 Adaptation UART Re-Init Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7063_1.fw(560), 1\7063_5.fw(800) Version 1.0.0.1: ID: 211275 Display correction in IO-Map on SGC Targets Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7063_1.fw(530) |
|||||