1.10.4.2 * 30/04/2026 1 MB EXE AS4_HW_8ESMC59316.exe
Descrizione V4.2 HW Upgrade (8ESMC59316)

Revision information 8ESMC59316

Version 1.10.4.2:

ID: SFXA-8057
HW-Upgrade 1.10.4.2
FW Version 360

Note:
-install mapp Safety Version 6.4.2 for the actual descriptionsof error numbers

Channel description changed: no
Configuration description changed: no
Firmware changed: yes

ID: SFXA-7710
Bugfix: The logger entry -2147302217/-2147298121 could be reported incorrectly
The following logger entry could have been incorrectly reported by SBT due tonoisycurrent measurement signals.
-2147302217/-2147298121: SMC: Safe Brake Test- Current fell below parametrized test current threshold
Channel description changed: no
Configuration description changed: no
Firmware changed: yes

ID: SFXA-5574
Improvement of processor utilization
Improvementof processor utilization
Channel description changed: no
Configuration description changed: no
Firmware changed: yes

ID: SFXA-4963
Bugfix: Sporadic error '7082: Encoder: Link to encoder disturbed' with configured Safe Speed Observer (SSO).
When using the Safe Speed Observer (SSO) (configuring the parameter 'ES-Encoder type' to the values 'Safe speed observer - Rotatory', 'Safe speed observer - Linear', or 'Safe speed observer'), the error '7082: Encoder: Link to encoder disturbed' sporadically occurred during startup,preventing the controller from being switched on. This limited availability has been resolved.
Channel description changed: no
Configuration description changed: no
Firmware changed: yes

ID: SFXA-4705
Bugfix: Overly restrictive brake output monitoring led to an error with the logger entry -2147298061 /-2147302157
The overly restrictive brake output monitoring couldlead to an error with thefollowing logger entry for third-party motors:
-2147298061 / -2147302157: SMC FFS (Functional Fail Safe): Safe outputs - test status has changed: Info0: 0x00, Info1: 0x00, Info2: 0x1D, Info3: 0x00, Info4: 0x0X
Channel description changed: no
Configuration description changed: no
Firmware changed: yes

ID: SFXA-4704
Bugfix: A PWM error with the logger entry -2147301124 / -2147297028 led to a failure of the encoder evaluation
The following logger entry, as part of PWM monitoring, led to a failure of the encoder evaluation :
-2147301124 / -2147297028: SMC: SMC FFS (Functional Fail Safe): Internal error, FPGA communication: Info0:0x000x, Info1:0xXXXX0070 ... 0xXXXX0074
As a result, the deactivated encoder evaluationled to errors when using safety functions that require safe position.
Channel description changed: no
Configuration description changed: no
Firmware changed: yes

ID: SFXA-4442
Bugfix: "EUS - count of physical reference system" was not taken into accountin the calculation of the RSP lag tolerance.
If the parameter “EUS - Count of physical reference system” was configured >1, the RSP overrun tolerance was calculated incorrectly.
As a result, the diagnosis of an impermissible movement of the axis in the switched-off state was reduced. As this diagnosis has no safety relevance, this error correction is only used to improve the diagnosis.
Channel description changed: no
Configuration description changed: no
Firmware changed: yes

ID:SFXA-4441
Bugfix: Encoder exchange lead to invalid RSP encoder position onthe other axes
For modules with several axes, an encoder exchange resultedin the stored RSP position becoming invalid on the axes on where no encoder exchange was executed.
Channel description changed: no
Configuration description changed: no
Firmware changed: yes

ID: SFXA-4439
Bugfix: The logger entry -2147298077/-2147302173 could be reported incorrectly
The following logger entry could be reported incorrectly for certain encoder positions during homing.
-2147298077/-2147302173: SMC FFS (Functional Fail Safe):SMP, SLP - INT32 overflow of S_SafePosition
Channel description changed: no
Configuration description changed: no
Firmware changed: yes

ID:SFXA-4437
Improvement: SSO speed accuracy
Correcting the PWM phase shift improves the speed accuracy of the safe speed observer (SSO) at higher speeds. This increases the applicability of the SSO for various applications.
Channel description changed: no
Configuration description changed: no
Firmware changed: yes

ID: SFXA-4435
Improvement: Error messages
Structure and content of error messages has been improved.
Channel description changed: no
Configuration description changed: no
Firmware changed: yes

Version 1.10.4.0: (V351)

ID: 741845
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed:Yes

ID: 741995 / Support ID: 400298548
Improved encoder error handling
Alarm bit errors during initialization are reported by a defined Loggerentry and not by debugging information.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 741945 / Support ID: 400307322
Improved encoder error handling
When an alarm bit occurs, the alarm register is read out explicitly before changing to theerror state and the error information is entered in the Safety Logger.
EnDat communication is kept active for a few milliseconds so that the ACP firmware can still read out and report the operating state error sources.
Alarm bit errors during initialization are reported by a defined Logger entryand not by debugging information.
A separate Logger entry is generated if the encoder is not connected or an encoder timeout occurs.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 741890 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 742025
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received CRC data is not equal to sent CRC data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 742095 / Support ID: 400348100, 400348100, 400358931
Errors 7074, 7062, 7022, 7038, 7048, 35244 were sporadically reported when switching on (power on).
The following errors were sporadically reported during EnDat initialization triggered by switching on, a warm restart of the CPU or project download to theCPU or SafeLOGIC controller.
NCT:
7074: Encoder: SafeMOTION error
7062: Encoder: SafeMOTION module not ready
7022: Encoder: Initialization is active
7038: Encoder: Position value not synchronous with absolutevalue
7048: Error during the reading of encoder memory
35244: Encoder -Received position not valid

Safety Logger:
115956, -2147302156: SMC: Encoder - Received position not valid: Info0=0x000X, Info1=0x00000010
or
115956, -2147302156: SMC: Encoder - Received position not valid: Info0=0x000X, Info1=0x00000200
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

Version 1.10.3.1: (V342)

ID: 729650 / Support ID: 400351082
Bug fix: Homing status can be lost if a SLT violation occurs
The homing status respectively the safe position valid bit can be lost when the SLT torque limit is exceeded and therefore the SLT safety functions are triggered.

Automation Studio version: AS 4.2.5.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 729660 / Support ID: 400339046
Solved problem: SafeMOTION error 35016 can occur rarely at the transition from PreOp to Operational
Solved problem: SafeMOTION error 35016: SMC FS: internal error, cross communication of check points can occur rarely due to a timeout of the processor at the transition from PreOp to Operational.

Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

Version 1.10.3.0: (V341)

ID: 653015
Change: Reduction of errors in the current space vector by using the full Clarke transformation
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 653040
Change / Improvement: Stabilization, increasing the availability of the Safe Speed ??Observer
Channel description changed: No
Configuration description changed: No
Firmware changed:Yes

ID: 653210
New function: Checking safe encoder mounting
The information whether the encoder is safely mounted is read from the motor data stored in the encoder. If safety functions are used which require safe encoderevaluation and safe encoder mounting is not confirmed in the motor data (or the information is not available), it is automatically checked whether safeencoder monitoring is activated. If the configuration is wrong, the module changes into error state.

When using third-party motors or motors without a stored motor data record, the automatic check can be deactivated by setting theparameter "General settings - Encoder monitoring - Safe Encoder Mounting" to "Approved by user".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

Version 1.10.2.0: (V331)

ID: 624770 / Support ID: 400224079
Error 7014 or7015 after ACOPOS startup
If the encoder was used before the state "NotErrENC = TRUE" (see I/O Mapping of the SafeMOTION module), one of the followingerrors could have been reported:
- 7014: Encoder: CRC error during parameter transfer
- 7015: Encoder: Timeout error during parameter transfer

In addition, at least version 5.05.0 of ACP10 must be used to solve this problem.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 624780 / Support ID: 400250882
Error 115958 und 115959 after ACOPOS startup
When using an EnDat encoder, the following errors could be erroneously reported in rare cases during startup or encoder error acknowledgment:
- 115958: SMC: Encoder - Initialization error, Info1=0x000000FF
- 115959: SMC: Debug Information, Info1=0x23000000
- 115959: SMC: Debug Information, Info1=0x80400000
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 624785 / Support ID: 400251128
Network initialization accelerated
Network initialization was accelerated for the followingcases:
- Encoder not connected
- Encoder defective
- Unconfirmed change of encoder

For this new function at least version V5.05.0 of ACP10 must be used.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 624790 / Support ID: 400229368, 400248609
Logger entry 112174, 108078
Logger entry 112174,108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmwarechanged: No

ID: 624865
Neue Funktion: Safely Limited Torque (SLT)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 624870
New feature: Safely Limited Speed with Safe Speed Observer (SLS with SSO)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 624875
New feature: Blackout Mode (BM)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 624885
New feature: Safe Brake Test (SBT)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

Version 1.10.1.4: (V321)

ID: 601190
Display of the SafeModuleOK in Automation Studio
The status "SafeModuleOK" is displayed in the IO mapping of the SafeMOTION module in Automation Studio.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

Version 1.10.0.3: (V321)

ID: 594440
Alignment of "SafeMotion" character
The display of the "SafeMotion" character in the system designer was adapted.
This is not a functional change.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.10.0.2: (V321)

ID: 579575
Provide the internal cycle time for calculatingthe Safe Data Duration
The hardware description has been adjusted so that the correct internal cycletime is used to calculate the "Safe Data Duration" using the Network Analyzer.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.10.0.1: (V321)

ID: 556910
Error in HWX File: wrong HardwareModuleFamily
Attribute HardwareModuleFamily erroneously set to "AcoposMulti".
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.10.0.0: (V321)

ID: 481995
HW upgrade for support of 8ESMC59316
Channel description changed: no
Configuration description changed: no
Firmware changed: no
Versione Lingua
Sistema operativo
Data
Taglia
Tipologia Download
1.10.4.0 * 21/12/2022 1 MB EXE AS4_HW_8ESMC59316.exe
Descrizione V4.2 HW Upgrade (8ESMC59316)

Revision information 8ESMC59316

Version 1.10.4.0:

ID: 741845
Propagation delay statistics
The Propagation delay statistics can now be read out.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 741995 / Support ID: 400298548
Improved encoder error handling
Alarm bit errors during initialization are reported by a defined Logger entry and not by debugging information.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 741945 / Support ID: 400307322
Improved encoder error handling
When an alarm bit occurs, the alarm register is read out explicitly before changing to the error state and the error information is entered in the Safety Logger.
EnDat communication is kept active for a few milliseconds so that the ACP firmware can still read out and report the operating state error sources.
Alarm bit errors during initialization are reported by a defined Logger entry and not by debugging information.
A separate Logger entry is generated if the encoder is not connected or an encoder timeout occurs.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 741890 / Support ID: 400299371
Loss of safety connection
Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 742025
Failsafe at every boot
It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages:
-1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received CRC data is not equal to sent CRC data"
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 742095 / Support ID: 400348100, 400348100, 400358931
Errors 7074, 7062, 7022, 7038, 7048, 35244 were sporadically reported when switching on (power on).
The following errors were sporadically reported during EnDat initialization triggered by switching on, a warm restart of the CPU or project download to the CPU or SafeLOGIC controller.
NCT:
7074: Encoder: SafeMOTION error
7062: Encoder: SafeMOTION module not ready
7022: Encoder: Initialization is active
7038: Encoder: Position value not synchronous with absolute value
7048: Error during the reading of encoder memory
35244: Encoder - Received position not valid

Safety Logger:
115956, -2147302156: SMC: Encoder - Received position not valid: Info0=0x000X, Info1=0x00000010
or
115956, -2147302156: SMC: Encoder - Received position not valid: Info0=0x000X, Info1=0x00000200
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59316_1.fw(351), 1\59316_99.fw(351)

Version 1.10.3.1:

ID: 729650 / Support ID: 400351082
Bug fix: Homing status can be lost if a SLT violation occurs
The homing status respectively the safe position valid bit can be lost when the SLT torque limit is exceeded and therefore the SLT safety functions are triggered.

Automation Studio version: AS 4.2.5.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 729660 / Support ID: 400339046
Solved problem: SafeMOTION error 35016 can occur rarely at the transition from PreOp to Operational
Solved problem: SafeMOTION error 35016: SMC FS: internal error, cross communication of check points can occur rarely due to a timeout of the processor at the transition from PreOp to Operational.

Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59316_1.fw(342)

Version 1.10.3.0:

ID: 653015
Change: Reduction of errors in the current space vector by using the full Clarke transformation
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 653040
Change / Improvement: Stabilization, increasing the availability of the Safe Speed ??Observer
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 653210
New function: Checking safe encoder mounting
The information whether the encoder is safely mounted is read from the motor data stored in the encoder. If safety functions are used which require safe encoder evaluation and safe encoder mounting is not confirmed in the motor data (or the information is not available), it is automatically checked whether safe encoder monitoring is activated. If the configuration is wrong, the module changes into error state.

When using third-party motors or motors without a stored motor data record, the automatic check can be deactivated by setting the parameter "General settings - Encoder monitoring - Safe Encoder Mounting" to "Approved by user".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\59316_1.fw(341)

Version 1.10.2.0:

ID: 624770 / Support ID: 400224079
Error 7014 or7015 after ACOPOS startup
If the encoder was used before the state "NotErrENC = TRUE" (see I/O Mapping of the SafeMOTION module), one of the followingerrors could have been reported:
- 7014: Encoder: CRC error during parameter transfer
- 7015: Encoder: Timeout error during parameter transfer

In addition, at least version 5.05.0 of ACP10 must be used to solve this problem.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 624780 / Support ID: 400250882
Error 115958 und 115959 after ACOPOS startup
When using an EnDat encoder, the following errors could be erroneously reported in rare cases during startup or encoder error acknowledgment:
- 115958: SMC: Encoder - Initialization error, Info1=0x000000FF
- 115959: SMC: Debug Information, Info1=0x23000000
- 115959: SMC: Debug Information, Info1=0x80400000
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 624785 / Support ID: 400251128
Network initialization accelerated
Network initialization was accelerated for the followingcases:
- Encoder not connected
- Encoder defective
- Unconfirmed change of encoder

For this new function at least version V5.05.0 of ACP10 must be used.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 624790 / Support ID: 400229368, 400248609
Logger entry 112174, 108078
Logger entry 112174,108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 624865
Neue Funktion: Safely Limited Torque (SLT)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 624870
New feature: Safely Limited Speed with Safe Speed Observer (SLS with SSO)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 624875
New feature: Blackout Mode (BM)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 624885
New feature: Safe Brake Test (SBT)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\59316_1.fw(331)

Version 1.10.1.4:

ID: 601190
Display of the SafeModuleOK in Automation Studio
The status "SafeModuleOK" is displayed in the IO mapping of the SafeMOTION module in Automation Studio.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\59316_1.fw(321)

Version 1.10.0.3:

ID: 594440
Alignment of "SafeMotion" character
The display of the "SafeMotion" character in the system designer was adapted.
This is not a functional change.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59316_1.fw(321)

Version 1.10.0.2:

ID: 579575
Provide the internal cycle time for calculatingthe Safe Data Duration
The hardware description has been adjusted so that the correct internal cycle time is used to calculate the "Safe Data Duration" using the Network Analyzer.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59316_1.fw(321)

Version 1.10.0.1:

ID: 556910
Error in HWX File: wrong HardwareModuleFamily
Attribute HardwareModuleFamily erroneously set to "AcoposMulti".
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59316_1.fw(321)

Version 1.10.0.0:

ID: 481995
HW upgrade for support of 8ESMC59316
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59316_1.fw(321)
Versione Lingua
Sistema operativo
Data
Taglia
Tipologia Download
1.10.3.1 * 30/06/2021 1 MB EXE AS4_HW_8ESMC59316.exe
Descrizione V4.2 HW Upgrade (8ESMC59316)

Revision information 8ESMC59316

Version 1.10.3.1:

ID: 729650 / Support ID: 400351082
Bug fix: Homing status can be lost if a SLT violation occurs
The homing status respectively the safe position valid bit can be lost when the SLT torque limit is exceeded and therefore the SLT safety functions are triggered.

Automation Studio version: AS 4.2.5.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 729660 / Support ID: 400339046
Solved problem: SafeMOTION error 35016 can occur rarely at the transition from PreOp to Operational
Solved problem: SafeMOTION error 35016: SMC FS: internal error, cross communication of check points can occur rarely due to a timeout of the processor at the transition from PreOp to Operational.

Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\59316_1.fw(342)

Version 1.10.3.0:

ID: 653015
Change: Reduction of errors in the current space vector by using the full Clarke transformation
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 653040
Change / Improvement: Stabilization, increasing the availability of the Safe Speed ??Observer
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 653210
New function: Checking safe encoder mounting
The information whether the encoder is safely mounted is read from the motor data stored in the encoder. If safety functions are used which require safe encoder evaluation and safe encoder mounting is not confirmed in the motor data (or the information is not available), it is automatically checked whether safe encoder monitoring is activated. If the configuration is wrong, the module changes into error state.

When using third-party motors or motors without a stored motor data record, the automatic check can be deactivated by setting the parameter "General settings - Encoder monitoring - Safe Encoder Mounting" to "Approved by user".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\59316_1.fw(341)

Version 1.10.2.0:

ID: 624770 / Support ID: 400224079
Error 7014 or7015 after ACOPOS startup
If the encoder was used before the state "NotErrENC = TRUE" (see I/O Mapping of the SafeMOTION module), one of the followingerrors could have been reported:
- 7014: Encoder: CRC error during parameter transfer
- 7015: Encoder: Timeout error during parameter transfer

In addition, at least version 5.05.0 of ACP10 must be used to solve this problem.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 624780 / Support ID: 400250882
Error 115958 und 115959 after ACOPOS startup
When using an EnDat encoder, the following errors could be erroneously reported in rare cases during startup or encoder error acknowledgment:
- 115958: SMC: Encoder - Initialization error, Info1=0x000000FF
- 115959: SMC: Debug Information, Info1=0x23000000
- 115959: SMC: Debug Information, Info1=0x80400000
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 624785 / Support ID: 400251128
Network initialization accelerated
Network initialization was accelerated for the followingcases:
- Encoder not connected
- Encoder defective
- Unconfirmed change of encoder

For this new function at least version V5.05.0 of ACP10 must be used.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 624790 / Support ID: 400229368, 400248609
Logger entry 112174, 108078
Logger entry 112174,108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 624865
Neue Funktion: Safely Limited Torque (SLT)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 624870
New feature: Safely Limited Speed with Safe Speed Observer (SLS with SSO)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 624875
New feature: Blackout Mode (BM)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 624885
New feature: Safe Brake Test (SBT)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\59316_1.fw(331)

Version 1.10.1.4:

ID: 601190
Display of the SafeModuleOK in Automation Studio
The status "SafeModuleOK" is displayed in the IO mapping of the SafeMOTION module in Automation Studio.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\59316_1.fw(321)

Version 1.10.0.3:

ID: 594440
Alignment of "SafeMotion" character
The display of the "SafeMotion" character in the system designer was adapted.
This is not a functional change.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59316_1.fw(321)

Version 1.10.0.2:

ID: 579575
Provide the internal cycle time for calculatingthe Safe Data Duration
The hardware description has been adjusted so that the correct internal cycle time is used to calculate the "Safe Data Duration" using the Network Analyzer.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59316_1.fw(321)

Version 1.10.0.1:

ID: 556910
Error in HWX File: wrong HardwareModuleFamily
Attribute HardwareModuleFamily erroneously set to "AcoposMulti".
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59316_1.fw(321)

Version 1.10.0.0:

ID: 481995
HW upgrade for support of 8ESMC59316
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59316_1.fw(321)
Versione Lingua
Sistema operativo
Data
Taglia
Tipologia Download
1.10.3.0 * 05/12/2019 1 MB EXE AS4_HW_8ESMC59316.exe
Descrizione V4.2 HW Upgrade (8ESMC59316)

Revision information 8ESMC59316

Version 1.10.3.0:

ID: 653015
Change: Reduction of errors in the current space vector by using the full Clarke transformation
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 653040
Change / Improvement: Stabilization, increasing the availability of the Safe Speed ??Observer
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 653210
New function: Checking safe encoder mounting
The information whether the encoder is safely mounted is read from the motor data stored in the encoder. If safety functions are used which require safe encoder evaluation and safe encoder mounting is not confirmed in the motor data (or the information is not available), it is automatically checked whether safe encoder monitoring is activated. If the configuration is wrong, the module changes into error state.

When using third-party motors or motors without a stored motor data record, the automatic check can be deactivated by setting the parameter "General settings - Encoder monitoring - Safe Encoder Mounting" to "Approved by user".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\59316_1.fw(341)

Version 1.10.2.0:

ID: 624770 / Support ID: 400224079
Error 7014 or7015 after ACOPOS startup
If the encoder was used before the state "NotErrENC = TRUE" (see I/O Mapping of the SafeMOTION module), one of the followingerrors could have been reported:
- 7014: Encoder: CRC error during parameter transfer
- 7015: Encoder: Timeout error during parameter transfer

In addition, at least version 5.05.0 of ACP10 must be used to solve this problem.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 624780 / Support ID: 400250882
Error 115958 und 115959 after ACOPOS startup
When using an EnDat encoder, the following errors could be erroneously reported in rare cases during startup or encoder error acknowledgment:
- 115958: SMC: Encoder - Initialization error, Info1=0x000000FF
- 115959: SMC: Debug Information, Info1=0x23000000
- 115959: SMC: Debug Information, Info1=0x80400000
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 624785 / Support ID: 400251128
Network initialization accelerated
Network initialization was accelerated for the followingcases:
- Encoder not connected
- Encoder defective
- Unconfirmed change of encoder

For this new function at least version V5.05.0 of ACP10 must be used.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 624790 / Support ID: 400229368, 400248609
Logger entry 112174, 108078
Logger entry 112174,108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 624865
Neue Funktion: Safely Limited Torque (SLT)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 624870
New feature: Safely Limited Speed with Safe Speed Observer (SLS with SSO)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 624875
New feature: Blackout Mode (BM)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 624885
New feature: Safe Brake Test (SBT)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\59316_1.fw(331)

Version 1.10.1.4:

ID: 601190
Display of the SafeModuleOK in Automation Studio
The status "SafeModuleOK" is displayed in the IO mapping of the SafeMOTION module in Automation Studio.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\59316_1.fw(321)

Version 1.10.0.3:

ID: 594440
Alignment of "SafeMotion" character
The display of the "SafeMotion" character in the system designer was adapted.
This is not a functional change.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59316_1.fw(321)

Version 1.10.0.2:

ID: 579575
Provide the internal cycle time for calculatingthe Safe Data Duration
The hardware description has been adjusted so that the correct internal cycle time is used to calculate the "Safe Data Duration" using the Network Analyzer.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59316_1.fw(321)

Version 1.10.0.1:

ID: 556910
Error in HWX File: wrong HardwareModuleFamily
Attribute HardwareModuleFamily erroneously set to "AcoposMulti".
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59316_1.fw(321)

Version 1.10.0.0:

ID: 481995
HW upgrade for support of 8ESMC59316
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59316_1.fw(321)
Versione Lingua
Sistema operativo
Data
Taglia
Tipologia Download
1.10.2.0 * 08/01/2019 1 MB EXE AS4_HW_8ESMC59316.exe
Descrizione V4.2 HW Upgrade (8ESMC59316)

Revision information 8ESMC59314

Version 1.10.2.0:

ID: 624770 / Support ID: 400224079
Error 7014 or7015 after ACOPOS startup
If the encoder was used before the state "NotErrENC = TRUE" (see I/O Mapping of the SafeMOTION module), one of the followingerrors could have been reported:
- 7014: Encoder: CRC error during parameter transfer
- 7015: Encoder: Timeout error during parameter transfer

In addition, at least version 5.05.0 of ACP10 must be used to solve this problem.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 624780 / Support ID: 400250882
Error 115958 und 115959 after ACOPOS startup
When using an EnDat encoder, the following errors could be erroneously reported in rare cases during startup or encoder error acknowledgment:
- 115958: SMC: Encoder - Initialization error, Info1=0x000000FF
- 115959: SMC: Debug Information, Info1=0x23000000
- 115959: SMC: Debug Information, Info1=0x80400000
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 624785 / Support ID: 400251128
Network initialization accelerated
Network initialization was accelerated for the followingcases:
- Encoder not connected
- Encoder defective
- Unconfirmed change of encoder

For this new function at least version V5.05.0 of ACP10 must be used.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 624790 / Support ID: 400229368, 400248609
Logger entry 112174, 108078
Logger entry 112174,108078 could happen sporadically with large projects.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 624865
Neue Funktion: Safely Limited Torque (SLT)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 624870
New feature: Safely Limited Speed with Safe Speed Observer (SLS with SSO)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 624875
New feature: Blackout Mode (BM)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 624885
New feature: Safe Brake Test (SBT)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\59314_1.fw(331)

Version 1.10.1.4:

ID: 601190
Display of the SafeModuleOK in Automation Studio
The status "SafeModuleOK" is displayed in the IO mapping of the SafeMOTION module in Automation Studio.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\59314_1.fw(321)

Version 1.10.0.4:

ID: 601190
Display of the SafeModuleOK in Automation Studio
The status "SafeModuleOK" is displayed in the IO mapping of the SafeMOTION module in Automation Studio.
Channel description changed: Yes
Configuration description changed: No
Firmwarechanged: No
Firmware: 1\59314_1.fw(321)

Version 1.10.0.3:

ID: 594440
Alignment of "SafeMotion" character
The display of the "SafeMotion" character in the system designer was adapted.
This is not a functional change.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59314_1.fw(321)

Version 1.10.0.2:

ID: 579575
Provide the internal cycle time for calculating the Safe Data Duration
The hardware description has been adjusted so that the correct internal cycle time is used to calculate the "Safe Data Duration" using the Network Analyzer.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\59314_1.fw(321)

Version 1.10.0.1:

ID: 556910
Error in HWX File: wrong HardwareModuleFamily
Attribute HardwareModuleFamily erroneously set to "AcoposMulti".
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59314_1.fw(321)

Version 1.10.0.0:

ID: 539395
HWupgrade for support of 8ESMC59314
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59314_1.fw(321)
Versione Lingua
Sistema operativo
Data
Taglia
Tipologia Download
1.10.0.1 * 11/10/2017 1,007 KB EXE AS4_HW_8ESMC59316.exe
Descrizione V4.2 HW Upgrade (8ESMC59316)

Revision information 8ESMC59314

Version 1.10.0.1:

ID: 556910
Error in HWX File: wrong HardwareModuleFamily
Attribute HardwareModuleFamily erroneously set to "AcoposMulti".
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59314_1.fw(321)

Version 1.10.0.0:

ID: 539395
HW upgrade for support of 8ESMC59314
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\59314_1.fw(321)