DWL@DWL10000878273
| Version | Language | Operating System | Date | Size | Type | Download |
|---|---|---|---|---|---|---|
| 1.11.1.1 | * | 10/07/2026 | 1 MB | EXE | AS6_HW_X20IF1086-2.exe | |
| Description |
V6.0 HW Upgrade (X20IF1086-2) Revision information X20IF1086-2 Version 1.11.1.1: ID: Firmware signature enables automatic verification of the authenticity on the target system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source. Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.11.0.0: ID: Adaptations for AutomationStudio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.10.0.0: ID: 705075 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operated in operating mode "Ethernet" and connected to a POWERLINK network in this mode, the interface could fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 715195 Support for automatic DNA configuration from AS 4.10.01 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 719430 Extended diagnostic for miminal latency input stations Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\46165_0.pci(36360), 1\46165a0.epl(142) Version 1.9.0.0: ID: 652275 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 652360 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46165_0.pci(35848), 1\46165a0.epl(140) Version 1.8.0.0: ID: 636420 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46165_0.pci(35336), 1\46165a0.epl(138) Version 1.7.0.0: ID: 603500 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no inputdata to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\46165_0.pci(34823), 1\46165a0.epl(136) Version 1.6.0.0: ID: 539760 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46165_0.pci(33543), 1\46165a0.epl(131) Version 1.5.0.0: ID: 503430 X20-Compact-S support Channel description changed: No Configuration description changed: No Firmware changed: No ID: 504210 Documentation updated Version 1.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46165_0.pci(32775), 1\46165a0.epl(128) Version 1.3.0.0: ID: 443855 IP packets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46165_0.pci(32775), 1\46165a0.epl(128) Version 1.2.0.0: ID: 417930 SupportBonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 417935 Supportof Poll Response Chaining on iCN Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424030 POWERLINK V2: "Controlled node" mode In networks with heavy SoCjitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424105 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46165_0.pci(32519), 1\46165a0.epl(127) Version 1.1.3.0: ID: 358960 POWERLINK MN mode: If "Multiplexing prescale" >= 9, then the input data of the multiplexed stations that were configured in the last "network cycle" were not transferred in certain configurations. Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 359180 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result of high asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360200 POWERLINK V1 MN mode Error correction: Cyclic input data and net time toggle between the last two received values when CNs dropout. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360255 POWERLINK V1 MN mode: "Nettime SoC" is not increased. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.1.2.0: ID: 332430 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication failsin some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 336695 POWERLINK V2 MN mode: It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337455 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46165_0.pci(30725), 1\46165a0.epl(120) Version 1.1.1.1: ID: 314495 Bitmap changed Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46165_0.pci(29700), 1\46165a0.epl(116) Version 1.1.1.0: ID: 293205 Corrected position of the Node Switches Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46165_0.pci(29700), 1\46165a0.epl(116) Version 1.1.0.0: ID: 285965 POWERLINK V2 CN mode: Asynchronous packets lost when there is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 285980 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 286015 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46165_0.pci(29699), 1\46165a0.epl(116) Version 1.0.0.0: ID: 246210 First version. Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 1\46165_0.pci(28674), 1\46165a0.epl(112) |
|||||