DWL@DWL10000777862
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
|---|---|---|---|---|---|---|
| 3.1.0.2 | * | 07/10/2026 | 480 KB | EXE | AS6_HW_X20SI4100.exe | |
| Beskrivelse |
V6.0 HW Upgrade (X20SI4100) Revision information X20SI4100 Version 3.1.0.2: ID: Firmware signature enables automatic verification of the authenticity on the target system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source. Channel description changed: no Configuration description changed: yes Firmware changed: no Version 3.1.0.1: ID: FUVI-12963 SafetyPlus Public Release Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\7613_1.fw(581) Version 3.1.0.0: ID: FUVI-12963 SafetyPlus Public Release Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\7613_1.fw(581) Version 3.0.0.0: ID: FUVI-11177 New data sheet V3.0.0 New data sheet V3.0.0 Channel description changed: No Configuration description changed: No Firmware changed: No ID: FUVI-11176 First official release for Safety+ First official release for Safety+ Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\7613_1.fw(581) Version 2.6.1.0: ID: QCAS-240 Test pulse generation and evaluation process corrected The time sequence for test pulse generation and evaluation has been revised. Channels areacknowledged simultaneously after a short circuit, there is no discrepancy error. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\7613_1.fw(581) Version 2.6.0.0: ID: 780150 Correction of the input filter with set "Filter off". Correction of the input filter, if a "Filter off" is set and a channel error is detected. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 780235 New data sheet V2.20 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 780405 Configuration for Power Calculation available The Configuration for Power Calculation is now available in Automation Studio Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\7613_1.fw(580) Version 2.4.0.0: ID: 715250 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 726615 The power calculation of the modules is supported The data for the power calculation of the data sheet is includedin the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727135 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\7613_1.fw(574) Version 2.3.1.0: ID: 706335 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 706395 New data sheet V2.08 For changes see chapter "Version history" in the datasheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\7613_1.fw(573) Version 2.3.0.0: ID: 675425 The OSDD signal at the pulse output iscorrected. The OSDD signal at the pulse output is output correctly even when not in use. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692135 Supportof the DYNlink interface The DYNlink interface is supported by the safe inputs. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 696570 New data sheet V2.07 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\7613_1.fw(572) Version 2.2.0.1: ID: 668565 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688730 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longerthan the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689705 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689940 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 690085 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\7613_1.fw(571) Version 2.1.0.0: ID: 644160 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\7613_1.fw(570) Version 1.10.10.0: ID: 622695 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 6\7613_1.fw(301), 7\7613_1.fw(331) Version 1.10.9.1: ID: 643145 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 6\7613_1.fw(301), 7\7613_1.fw(330) Version 1.10.9.0: ID: 618235 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 6\7613_1.fw(301), 7\7613_1.fw(330) Version 1.10.1.1: ID:560030 Missing XOSDD file added Missing XOSDD file added Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 6\7613_1.fw(301), 7\7613_1.fw(325) Version 1.10.1.0: ID: 380915 X20(c)SI9100: warn about invalid two channel processing mode X20(c)SI9100: SafeDESIGNER generates a warning during compile if a two-channel evaluation channel is used but the according parameter "Two Channel Processing Mode" is "none". Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 501195 Remove parameter discrepance time from SafeDigitalInput04 The unused parameter Discrepance Time will be removed from group SafeDigitalInput04. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532670 Update ECAD data Update ECAD data Channeldescription changed: No Configuration description changed: Yes Firmware changed: No ID: 539145 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 541335 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 550700 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 550740 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 556265 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 6\7613_1.fw(301), 7\7613_1.fw(325) Version 1.10.0.2: ID: 467370 Added information about internal cycletime Added information about internal cycletime Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 6\7613_1.fw(301), 7\7613_1.fw(320) Version 1.10.0.1: ID: 472990 Support of release 1.10 including openSAFETY1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 472995 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 6\7613_1.fw(301), 7\7613_1.fw(320) Version 1.9.1.0: ID: 424625 change of input filter The behaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424630 fw valid from SafetyRelease 1.4 on The firmware is used for all SafetyReleases from 1.4 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 424635 Update Online Help UpdateOnline Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 6\7613_1.fw(301) Version 1.9.0.0: ID: 338270 2-channel evaluation: additional information at warning If warning "discrepancy time elapsed" appears for 2-channel evaluation, info0 will now display the chosen PLCopen FBK (equivalent or antivalent). Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 413825 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 413930 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414330 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 3\7613_1.fw(282), 4\7613_1.fw(290), 5\7613_1.fw(300) Version 1.6.0.9: ID: 393880 Update Online Help Update Online Help V1.80 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273),3\7613_1.fw(282), 4\7613_1.fw(290) Version 1.6.0.8: ID: 388395 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 3\7613_1.fw(282), 4\7613_1.fw(290) Version 1.6.0.7: ID: 339215 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 3\7613_1.fw(282), 4\7613_1.fw(290) Version 1.6.0.6: ID: 335360 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335365 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 3\7613_1.fw(282), 4\7613_1.fw(290) Version 1.6.0.0: ID: 313700 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 3\7613_1.fw(282), 4\7613_1.fw(290) Version 1.5.0.4: ID: 303365 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 3\7613_1.fw(282), 4\7613_1.fw(290) Version 1.5.0.3: ID: 287430 New feature Discrepancy time maximum from 500ms to 10s increased. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 290250 Datasheet Version 1.50 Datasheet version 1.50 added in Html format Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 3\7613_1.fw(282), 4\7613_1.fw(290) Version 1.4.1.3: ID: 284610 Release für kompatibles Safety Release 1.5 ID 284600 Parameter for backwards compatibility in description file changed Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 3\7613_1.fw(282) Version 1.4.1.1: ID: 272195 Release for Safety Release 1.5 Release for Safety Release 1.5 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 3\7613_1.fw(282) Version 1.4.0.1: ID: 225420 Safety Release 1.4 - one can configure the channel that shall be used as pulse source for testpulse with mode "internal" (see manual) - different levels for logger entires: "Info", "Warning" or "Error" (AR B3.05 required) - logger entries with level "Info" or "Warning" are sent by only 1 ofthe 2 safety processors to reduce the number of messages - X2X diagnostics data points (AR 3.08 required) Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 3\7613_1.fw(282) Version 1.2.1.0: ID: 210370 Pulse_Mode "external": automatic increment of "Filter_off_us" For Pulse_Mode "external" the automatic increment of parameter "Filter_off_us" was less than the 5ms described in the documentation. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273) Version 1.2.0.3: ID: 217720 changes in HWC fixed typos of safety parameters enabled for AR B2.96 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7613_1.fw(262), 2\7613_1.fw(272) Version 1.2.0.0: ID: 183260 reduced async communication at boot time parameters are stored locally and will only be transmitted in case of changes Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 186455 flashing of SE-LEDs new states of SE-LEDs: single flash: safety firmware is still in state PreOp (waiting forstart command from SL) double flash: safety firmware is in operational, but cyclic data connectionto SL is not valid Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 194140 increased maximum value of input filters input filters can be paramtrized up to 500ms (instead of 100ms) Channel descriptionchanged: No Configuration description changed: No Firmware changed:No ID: 199330 operation in cold environment problems when operating in cold environment (0 .. 10°C) solved (logger entries 99850 und 103946) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 3\7613_1.fw(282) Version 1.1.4.0: ID: 168365 solved sporadic firmware update problems solved sporadic firmware update problems Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7613_1.fw(262) Version1.1.3.0: ID: 180045 enhacements HWC state information of 2-channel evaluation can be mapped Aprol support Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7613_1.fw(262), 2\7613_1.fw(273), 3\7613_1.fw(282) Version 1.1.1.0: ID: 163865 first official release first official release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7613_1.fw(259) |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 3.1.0.1 | * | 18/06/2026 | 476 KB | EXE | AS6_HW_X20SI4100.exe | |
| Beskrivelse |
V6.0 HW Upgrade (X20SI4100) Revision information X20SI4100 Version 3.1.0.1: ID: FUVI-12963 SafetyPlus Public Release Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\56666_1.fw(581) Version 3.0.0.0: ID: FUVI-11177 New data sheet V3.0.0 New data sheet V3.0.0 Channel description changed: No Configuration description changed: No Firmware changed: No ID: FUVI-11176 First official releasefor Safety+ First official release for Safety+ Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56666_1.fw(581) Version 2.6.1.0: ID: QCAS-240 Test pulse generation and evaluation process corrected The timesequence for test pulse generation and evaluation has been revised.Channels are acknowledged simultaneously after a short circuit, there is no discrepancyerror. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\56666_1.fw(581) Version 2.6.0.0: ID: 780150 Correction of the input filter with set "Filter off". Correction of the input filter, if a "Filter off" is set and a channel error is detected. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 780235 New data sheet V2.20 For changes see chapter "Version history"in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 780405 Configuration for Power Calculation available The Configuration for Power Calculation is now available in Automation Studio Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\56666_1.fw(580) Version 2.4.0.0: ID: 715250 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 726615 The power calculation of the modulesis supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727135 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed:No Firmware changed: No Firmware: 10\56666_1.fw(574) Version2.3.1.0: ID: 706335 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706395 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56666_1.fw(573) Version 2.3.0.0: ID: 675425 The OSDD signal at the pulse output is corrected. The OSDD signal at the pulse output is output correctly even when not in use. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692135 Support of the DYNlink interface The DYNlink interface is supported by the safe inputs. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 696570 New datasheet V2.07 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56666_1.fw(572) Version 2.2.0.1: ID: 668565 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688730 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689705 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689940 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690085 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56666_1.fw(571) Version 2.1.0.0: ID: 644160 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\56666_1.fw(570) Version 1.10.10.0: ID: 622695 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 7\56666_1.fw(331) Version 1.10.9.1: ID: 643145 data sheet V1.141 See chapture "Version history" inthe data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 7\56666_1.fw(330) Version 1.10.9.0: ID: 618235 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 7\56666_1.fw(330) Version 1.10.1.0: ID: 380915 X20(c)SI9100: warn about invalid two channel processing mode X20(c)SI9100: SafeDESIGNER generates a warning during compile if a two-channel evaluation channel is used but the according parameter "Two Channel Processing Mode" is "none". Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 501195 Remove parameter discrepance time from SafeDigitalInput04 The unused parameter Discrepance Time will be removed from group SafeDigitalInput04. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532670 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 539145 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 541335 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 550700 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 550740 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 556265 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 7\56666_1.fw(325) Version 1.10.0.2: ID: 467370 Added information about internal cycletime Added information about internal cycletime Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 7\56666_1.fw(320) Version 1.10.0.1: ID: 472990 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 472995 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 7\56666_1.fw(320) Version 1.9.1.0: ID: 424670 change of input filter The behaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424675 UpdateOnline Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 424685 fw valid from SafetyRelease 1.7 on The firmware is usedfor all SafetyReleases from 1.7 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 6\56666_1.fw(301) Version 1.9.0.0: ID: 413885 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414045 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414300 2-channel evaluation: additional information at warning If warning "discrepancy time elapsed" appears for 2-channel evaluation, info0 will now display the chosenPLCopen FBK (equivalent or antivalent). Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 414385 Update Online Help Update Online Help V1.90 Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 4\56666_1.fw(290), 5\56666_1.fw(300) Version 1.6.0.9: ID: 393885 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 4\56666_1.fw(290) |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 3.0.0.0 | * | 23/07/2025 | 776 KB | EXE | AS6_HW_X20SI4100.exe | |
| Beskrivelse |
V6.0 HW Upgrade (X20SI4100) Revision information X20SI4100 Version 3.0.0.0: ID: FUVI-11177 New data sheet V3.0.0 New data sheet V3.0.0 Channel description changed: No Configuration description changed: No Firmware changed: No ID: FUVI-11176 First official release for Safety+ First official release for Safety+ Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56666_1.fw(581) Version 2.6.1.0: ID: QCAS-240 Test pulse generation and evaluation process corrected The time sequence for test pulse generation and evaluation has been revised. Channels are acknowledged simultaneously after a short circuit, there is no discrepancy error. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\56666_1.fw(581) Version 2.6.0.0: ID: 780150 Correction of the input filter with set "Filter off". Correction of the input filter, if a "Filter off" is set and a channel error is detected. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 780235 New data sheet V2.20 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 780405 Configuration for Power Calculation available The Configurationfor Power Calculation is now available in Automation Studio Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\56666_1.fw(580) Version 2.4.0.0: ID: 715250 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 726615 The power calculation of the modules is supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727135 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56666_1.fw(574) Version 2.3.1.0: ID: 706335 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring ofmodule cycle time andslot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706395 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56666_1.fw(573) Version 2.3.0.0: ID: 675425 The OSDD signal at the pulse output is corrected. The OSDD signal at the pulse output is output correctly even when not in use. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692135 Support of the DYNlink interface The DYNlink interface is supported by the safe inputs. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 696570 New data sheet V2.07 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56666_1.fw(572) Version 2.2.0.1: ID: 668565 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688730 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689705 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689940 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690085 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56666_1.fw(571) Version 2.1.0.0: ID: 644160 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\56666_1.fw(570) Version 1.10.10.0: ID: 622695 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 7\56666_1.fw(331) Version1.10.9.1: ID: 643145 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time hasbeen updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 7\56666_1.fw(330) Version 1.10.9.0: ID: 618235 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 7\56666_1.fw(330) Version 1.10.1.0: ID: 380915 X20(c)SI9100: warn about invalid two channelprocessing mode X20(c)SI9100: SafeDESIGNER generates a warning during compile if a two-channel evaluation channel is used but the according parameter "Two Channel Processing Mode" is "none". Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 501195 Remove parameter discrepance time from SafeDigitalInput04 The unused parameter Discrepance Time will be removed from group SafeDigitalInput04. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532670 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 539145 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 541335 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 550700 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 550740 Provide CRC of the Firmware ProvideCRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 556265 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 7\56666_1.fw(325) Version 1.10.0.2: ID: 467370 Addedinformation about internal cycletime Added information about internal cycletime Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 7\56666_1.fw(320) Version 1.10.0.1: ID: 472990 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easierparametrizationof timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 472995 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 7\56666_1.fw(320) Version1.9.1.0: ID: 424670 change of input filter The behaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424675 Update Online Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 424685 fw valid from SafetyRelease 1.7 on The firmware is used for all SafetyReleases from 1.7 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 6\56666_1.fw(301) Version 1.9.0.0: ID: 413885 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414045 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414300 2-channel evaluation: additional information at warning If warning "discrepancy time elapsed" appears for 2-channel evaluation, info0 will now display the chosen PLCopen FBK (equivalent or antivalent). Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 414385 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed:No Firmware changed: No Firmware: 4\56666_1.fw(290), 5\56666_1.fw(300) Version 1.6.0.9: ID: 393885 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 4\56666_1.fw(290) |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 2.6.1.0 | * | 04/03/2025 | 2 MB | EXE | AS6_HW_X20SI4100.exe | |
| Beskrivelse |
V6.0 HW Upgrade (X20SI4100) Revision information X20SI4100 Version 2.6.1.0: ID: QCAS-240 Test pulse generation and evaluation process corrected The time sequence for test pulse generation and evaluation has been revised. Channels are acknowledged simultaneously after a short circuit, there is no discrepancy error. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\56666_1.fw(581) Version 2.6.0.0: ID: 780150 Correction of the input filter with set "Filter off". Correction of the input filter, if a "Filter off" is set and a channel error is detected. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 780235 New data sheet V2.20 For changessee chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 780405 Configuration for Power Calculation available The Configuration for Power Calculation is now available in Automation Studio Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\56666_1.fw(580) Version 2.4.0.0: ID: 715250 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot,generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 726615 The power calculation of the modules is supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727135 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56666_1.fw(574) Version 2.3.1.0: ID: 706335 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706395 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56666_1.fw(573) Version 2.3.0.0: ID: 675425 The OSDD signal at the pulse output is corrected. The OSDD signal at the pulse output is output correctly even when not in use. Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 692135 Support of the DYNlink interface The DYNlink interface is supported by the safe inputs. Channel description changed:No Configuration description changed: Yes Firmware changed: Yes ID: 696570 New data sheet V2.07 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56666_1.fw(572) Version 2.2.0.1: ID: 668565 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688730 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689705 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689940 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690085 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56666_1.fw(571) Version 2.1.0.0: ID: 644160 major (evenincompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\56666_1.fw(570) Version 1.10.10.0: ID: 622695 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 7\56666_1.fw(331) Version 1.10.9.1: ID: 643145 data sheet V1.141 Seechapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 7\56666_1.fw(330) Version 1.10.9.0: ID: 618235 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 7\56666_1.fw(330) Version 1.10.1.0: ID: 380915 X20(c)SI9100: warn about invalid two channel processing mode X20(c)SI9100: SafeDESIGNER generates a warning during compile if a two-channel evaluation channel is used but the according parameter "Two Channel Processing Mode" is "none". Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 501195 Remove parameter discrepance time from SafeDigitalInput04 The unused parameter Discrepance Time will be removed from group SafeDigitalInput04. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532670 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 539145 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 541335 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 550700 Loggerentry on negativ edge of SafeModuleOK Ifa negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 550740 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 556265 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 7\56666_1.fw(325) Version 1.10.0.2: ID: 467370 Added information about internal cycletime Added information about internal cycletime Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 7\56666_1.fw(320) Version 1.10.0.1: ID: 472990 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY1.5 with easier parametrizationof timing parameters Channel descriptionchanged: No Configuration description changed: Yes Firmware changed: No ID: 472995 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 7\56666_1.fw(320) Version 1.9.1.0: ID: 424670 change of input filter The behaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424675 Update Online Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 424685 fw valid from SafetyRelease 1.7 on The firmware is used for all SafetyReleases from 1.7 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 6\56666_1.fw(301) Version 1.9.0.0: ID: 413885 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414045 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414300 2-channel evaluation: additional information at warning If warning "discrepancy time elapsed" appears for 2-channel evaluation, info0 will now display the chosen PLCopen FBK (equivalent or antivalent). Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 414385 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 4\56666_1.fw(290), 5\56666_1.fw(300) Version 1.6.0.9: ID: 393885 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 4\56666_1.fw(290) |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 2.6.0.0 | * | 05/03/2024 | 2 MB | EXE | AS6_HW_X20SI4100.exe | |
| Beskrivelse |
V6.0 HW Upgrade (X20SI4100) Revision information X20SI4100 Version 2.6.0.0: ID: 780150 Correction of the input filter with set "Filter off". Correction of the input filter, if a "Filter off" is set and a channel error is detected. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 780235 New data sheet V2.20 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 780405 / Support ID: 400412437 Configuration for Power Calculation available The Configuration for Power Calculation is now available in Automation Studio Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\56666_1.fw(580) Version 2.4.0.0: ID: 715250 / Support ID: 400345156 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc datais not equal to sent crc data" Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 726615 The power calculation of the modules is supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727135 New data sheet V2.10 For changes seechapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56666_1.fw(574) Version 2.3.1.0: ID: 706335 Limit values for the module cycle time adjusted The limit values for thecalculation and monitoring of module cycle time andslot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706395 New data sheet V2.08 Forchanges see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56666_1.fw(573) Version 2.3.0.0: ID:675425 / Support ID: 400311305 The OSDD signal at the pulse output is corrected. The OSDD signal at the pulse output is output correctly even when not in use. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692135 Support ofthe DYNlink interface The DYNlink interface is supported by the safe inputs. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 696570 New data sheet V2.07 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56666_1.fw(572) Version 2.2.0.1: ID: 668565 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688730 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689705 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689940 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690085 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\56666_1.fw(571) Version 2.1.0.0: ID: 644160 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\56666_1.fw(570) Version 1.10.10.0: ID: 622695 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 7\56666_1.fw(331) Version1.10.9.1: ID: 643145 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time hasbeen updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 7\56666_1.fw(330) Version 1.10.9.0: ID: 618235 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 7\56666_1.fw(330) Version 1.10.1.0: ID: 380915 / Support ID: 400132230 X20(c)SI9100: warn about invalid two channel processing mode X20(c)SI9100: SafeDESIGNER generates a warning during compile if a two-channel evaluation channel is used but the according parameter "Two Channel Processing Mode" is "none". Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 501195 / Support ID: 400198859, 400209221, 400214147, 400217227, 400221540, 400224198 Remove parameter discrepance time from SafeDigitalInput04 The unused parameter Discrepance Time will be removed from group SafeDigitalInput04. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 532670 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 539145 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 541335 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 550700 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 550740 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 556265 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 7\56666_1.fw(325) Version 1.10.0.2: ID: 467370 Added information about internal cycletime Added information about internal cycletime Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 7\56666_1.fw(320) Version 1.10.0.1: ID: 472990 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 472995 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 7\56666_1.fw(320) Version 1.9.1.0: ID: 424670 change of input filter The behaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424675 Update Online Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 424685 fw valid from SafetyRelease 1.7 on The firmware is used for all SafetyReleases from 1.7 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 6\56666_1.fw(301) Version 1.9.0.0: ID: 413885 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414045 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed:No ID: 414300 2-channel evaluation: additional information at warning If warning "discrepancy time elapsed" appears for 2-channel evaluation, info0 will now display the chosen PLCopen FBK (equivalent or antivalent). Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 414385 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 4\56666_1.fw(290), 5\56666_1.fw(300) Version 1.6.0.9: ID: 393885 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 4\56666_1.fw(290) |
|||||